Conductance as the reciprocal of resistance

Conductance, G, is how easily current flows through a component, the inverse of resistance. A resistor of 100 Ω has a conductance of 0.01 S, which is 10 mS. Most people think in ohms, but some circuit analyses are simpler in siemens, especially when elements sit in parallel, because parallel conductances add directly. Datasheets also list transconductance of transistors and amplifiers in millisiemens, and insulation leakage in nanosiemens. This page converts the prefixes. It starts at 10 S, which is 10,000 mS, and handles all six units in the menu, so a number from a datasheet in one prefix can be moved to the prefix an analysis needs.

The siemens and its prefix ladder

The siemens, symbol S, is the SI unit of conductance, equal to one ampere per volt or the reciprocal of one ohm. It is named for Werner von Siemens, and the General Conference on Weights and Measures adopted the name in 1971, replacing the older mho. Kilosiemens is 1,000 S, millisiemens is 0.001 S, microsiemens is 10⁻⁶ S, nanosiemens is 10⁻⁹ S and picosiemens is 10⁻¹² S. The formula on the page, mS = S × 1,000, is the default case. Every other pair on the page follows from the same powers of ten, so conversions are exact in either direction.

Ohms and siemens side by side

A handy mapping connects the prefixes to resistance. One kilosiemens is one milliohm, one millisiemens is one kiloohm, one microsiemens is one megaohm, one nanosiemens is one gigaohm and one picosiemens is one teraohm. A 10 kΩ resistor therefore has a conductance of 0.1 mS, which is 100 µS. A 1 MΩ leakage path is 1 µS. The page does not convert resistance directly, but the pairing helps you read a result. If you enter 470 µS and the answer shows 0.47 mS, the equivalent resistance is about 2.13 kΩ, found by taking the reciprocal of the conductance in siemens. A 50 Ω load, a common figure in radio work, is 20 mS, and a 75 Ω video line is about 13.3 mS. Series resistors need the opposite handling, since resistances add and conductances combine by the reciprocal rule, so keep track of which representation a formula expects.

Parallel paths add in siemens

The main practical reason to think in siemens is that conductances in parallel add. Take a 100 Ω resistor and a 220 Ω resistor in parallel. Their conductances are 10 mS and about 4.545 mS, which total 14.545 mS. The equivalent resistance is the reciprocal, 1/0.014545 S, or 68.75 Ω, which matches the product over sum rule. Working in millisiemens keeps the numbers readable, and the page helps when sources list parts in different prefixes. Convert each to the same prefix before adding, otherwise a 2.5 mS part and a 470 µS part can be added as 2.97 by mistake instead of 2.97 mS or 2,970 µS.

Transconductance and small-signal values

Transistor and tube datasheets list transconductance, the change in output current per change in input voltage, in siemens or millisiemens. A small MOSFET stage might show a figure of 20 to 100 mS, and a precision amplifier input stage can be a fraction of that. These are conductance units even though the quantity is a gain rather than a simple resistance. When a design tool wants the value in siemens, 25 mS becomes 0.025 S. The converter treats the number as the same unit family, and it is a good tool for checking that a model parameter entered in S, mS or µS agrees with the datasheet. Simulation decks such as SPICE netlists commonly want base units, so a datasheet value of 25 mS has to be typed as 0.025, while many datasheet graphs are plotted in millisiemens against drain current. A parameter entered with the wrong prefix can still let a simulation run and return a gain that is a thousand times off, so compare the first simulated gain with the datasheet before trusting later results.

Very small and very large values

Leakage currents through insulation, dielectrics and clean surfaces correspond to conductances in nanosiemens or picosiemens. A 250 pS leakage path is 0.25 nS, which is 4 GΩ. At the other end, kilosiemens appear for very low-resistance conductors such as busbars and welding paths, where 3 kS corresponds to roughly 0.33 mΩ. These ranges are far apart, and a conversion mistake of a factor of 1,000 can move a value from harmless to alarming. Always write the unit symbol with the number, and use the page to confirm values at the extremes of the ladder.

Case and symbol traps

Conductance symbols are easy to misread. S is the siemens, lowercase s is the second, and a mixed form such as mS means millisiemens while ms is a millisecond. A value like 5 µS can be mistaken for 5 µs if the case is lost in an email or PDF. The old unit mho, written as an inverted capital omega, equals one siemens, and older diagrams may use it. Sv is the sievert, an unrelated radiation unit. Avoid retyping values from scanned documents without checking case, and keep the unit with the number in every table. The prefix letter is as fragile as the unit letter. A capital M would mean mega, so 5 MS would be five megasiemens, a conductance far beyond any real component, while 5 mS is a common value. When a number in a report looks absurdly large or small, check the case of every letter before assuming the measurement is wrong.

Conductance, conductivity and the limits of this page

Conductance belongs to a particular component with a particular size and shape. Conductivity, in siemens per meter, belongs to a material, and the two connect through G = σA/L. A conductivity converter is a separate page in this family. This page does not convert resistance, compute equivalent circuits, or assess any installation limit, equipment rating or protection requirement. It restates a known conductance in a different prefix. For design work, rely on the component datasheet and the applicable standard, and use the page only for unit bookkeeping.

Checking a result through resistance

A reliable test for any conversion on this page is to turn both the input and the output into resistance. The reciprocal of 2.5 mS is 400 Ω, and the reciprocal of the converted 2,500 µS is also 400 Ω, so the two forms agree. The default shows the same thing at the large end: 10 S is 0.1 Ω, and so is 10,000 mS. A prefix mistake shows up immediately, because one of the two resistances will be off by a factor of 1,000 or more. The reciprocal step is a short calculator exercise, and it catches slips that a glance at the digits will miss, such as a result of 0.47 µS where 0.47 mS was meant.