Datasheets and design notes in mS
In electronics, conductance of a few millisiemens is typical for resistive networks and active devices. The transconductance of a field-effect transistor or a bipolar amplifier is listed in mS, and a 50 Ω transmission line has a conductance of 20 mS. Designers who think in ohms for resistors and in siemens for gain stages need to move between the two. This page multiplies the conductance in S by 1,000 and returns mS. It is a small step, though a slip of the prefix changes the gain of a stage by a factor of 1,000, which is easy to catch if you place the result next to a known pair such as 20 mS and 50 Ω.
Three places to the right and a reciprocal check
Milli is 10^-3, so 1 S equals 1,000 mS, and the formula is mS = S × 1,000. By hand, move the decimal point three places right: 0.025 S becomes 25 mS and 0.004 S becomes 4 mS. A reciprocal check is available too. A conductance of 10 mS means a resistance of 1 ÷ 0.01 = 100 Ω, and 1 mS means 1 kΩ. If the number in mS and the resistance in kΩ are not reciprocals of each other, the conversion went wrong. The unit symbols are mS for millisiemens and MS for megasiemens, a difference of a factor of 10^9, so check the capitalization on a datasheet. Scanned older tables sometimes print mho for the same unit, since the siemens replaced the older name mho for reciprocal ohms, and the numbers carry over unchanged.
A default of ten siemens
The page opens with 10 S and returns 10,000 mS. A conductance of 10 S is a resistance of 0.1 Ω, which belongs to power wiring rather than to signal circuits, so the default is a test of the prefix more than a design figure. In practice, mS values in electronics fall between a fraction of a millisiemens for high-value resistors and tens of mS for amplifier stages. Try 0.01 S and you get 10 mS, which is the conductance of a 100 Ω resistor. That pair appears everywhere in analog design and is a good one to memorize for sanity checks. The next pair to remember is 1 mS for 1 kΩ, followed by 0.1 mS for 10 kΩ, and a decade in resistance is always a decade in conductance, in the opposite direction.
Resistor values as conductance
A 1 kΩ resistor has a conductance of 1 mS, a 100 Ω resistor has 10 mS and a 4.7 kΩ resistor has 1 ÷ 4,700 = 0.000212766 S, which is 0.212766 mS. Thinking in conductance makes parallel networks easy, since the values add. A 4.7 kΩ and a 10 kΩ resistor in parallel have 0.212766 mS + 0.1 mS = 0.312766 mS, and the combined resistance is 1 ÷ 0.000312766 = 3,197 Ω, about 3.2 kΩ. The page handles the prefix change, and you supply the reciprocal on a calculator. Real resistors have tolerances, which carry over to the conductance, so a 1 percent part is good to about 1 percent in mS. A 2.2 kΩ part has 0.4545 mS, and a 330 Ω part has 3.0303 mS, values you will see when you size LED resistors, pull-ups and divider networks.
The 50 and 75 ohm cases
Coaxial cables and RF systems use characteristic impedances of 50 Ω and 75 Ω. The conductance of 50 Ω is 0.02 S, or 20 mS, and that of 75 Ω is 0.013333 S, or 13.333 mS. RF designers who work with admittance in a Smith chart read these numbers directly. A termination of 50 Ω across a line has a conductance of 20 mS, and adding a second 50 Ω in parallel doubles it to 40 mS, which halves the resistance to 25 Ω. The page converts the number only. It does not model line behavior, mismatch or loss, which depend on frequency and on the whole circuit. Video, antenna and test-bench cables are the usual places where the 50 and 75 ohm figures meet a conductance value in a spreadsheet or a simulator.
Transconductance and voltage gain
Transconductance gm is the change in output current per volt of input, in siemens. A bipolar transistor biased at 1 mA of collector current has a gm of about 40 mS at room temperature, found from the current divided by roughly 25 mV. A common-emitter stage with a 2.5 kΩ load has a voltage gain near gm times load, which is 0.04 S × 2,500 Ω = 100. A datasheet that lists gm in mS makes this multiplication straightforward. Gain depends on the bias point and on the temperature, so use the numbers as a starting estimate and verify the circuit with a simulation and a measurement. A MOSFET datasheet might list a transconductance of 20 mS at a stated drain current, which is 0.02 S, so a 5 kΩ load would give a gain near 100 in the same arithmetic.
From millisiemens back to siemens
Select millisiemens as the source and siemens as the target to reverse the conversion. The page divides by 1,000, so 25 mS becomes 0.025 S and 0.212766 mS becomes 0.000212766 S. Circuit simulators and formulas use siemens or ohms, so a value copied from a datasheet in mS must be converted. Write the conversion next to the number in a design note, for example 40 mS = 0.04 S, and the next reader can follow the steps. If a gain calculation comes out a thousand times off, look at the prefix first, since it is the most frequent source of mistakes in hand calculations of this kind. A power-of-ten check on the final voltage gain, which should be a plain number between about 1 and a few hundred for a single stage, catches most of them.
Bias current and temperature move a 40 mS figure
Conductance in a datasheet is specified at conditions such as a bias current, a temperature and sometimes a frequency. A value of 40 mS at one collector current is not valid at another, and it drifts as a part warms up. Resistor conductance is meaningful at low frequency, and at higher frequency parasitic capacitance and inductance modify the behavior. The converter treats the entered number as a fixed value. It is a unit tool for design notes and homework, and it does not replace the datasheet curves, a simulation or a measurement on the actual circuit.