Gigaseals, leaks and the picosiemens range
In patch-clamp work the quality of a recording starts with the seal between the glass pipette and the cell membrane. A seal resistance of 10 gigaohms is a conductance of 100 pS, and every picosiemens of leak adds noise and distorts the small currents being measured. The cell itself, its synapses and its channels are usually described in nanosiemens. A person writing a methods section or checking a recording sheet has numbers in both prefixes and wants them in one. This page multiplies a picosiemens value by 0.001 and returns nanosiemens, so leak and signal can be read as figures of the same kind.
Three decimal places between pico and nano
Pico is 10^-12 and nano is 10^-9, so one nanosiemens equals 1,000 picosiemens. The formula is nS = pS × 0.001, and the factor is exact because both prefixes are fixed powers of ten in the SI Brochure. A conductance of 150 pS is 0.15 nS, one of 2,500 pS is 2.5 nS, and 60 pS is 0.06 nS. In practice the shift is just three places to the left, which makes this one of the easiest prefix steps to check by eye. The siemens itself is one ampere per volt, so every figure on this page converts to a resistance by taking the reciprocal. A quick check: 0.1 nS is 10 gigaohms, 1 nS is 1 gigaohm and 10 nS is 100 megaohms.
A ten picosiemens leak next to a nanosiemens signal
The page opens with 10 pS, which is 0.01 nS. As a resistance that is 100 gigaohms, a very good seal. A leak of 150 pS is 0.15 nS, which corresponds to about 6.7 gigaohms and would be a poor seal for many recordings. Comparing either leak with a signal of a few nanosiemens shows how much of the measured conductance is real. A 5 nS synaptic conductance, for instance, equals 5,000 pS and 200 megaohms, so a 150 pS leak is three percent of it. If the converted number is larger than the one you typed, the units were entered in the wrong order.
Leakage current in a datasheet becomes a conductance
Electronics datasheets rarely print conductance. They list leakage as a current at a test voltage, for example 1 nA at 5 V for a reverse-biased photodiode or an input protection diode. Dividing current by voltage gives 0.2 nS, which is 200 pS. Two leakage paths of 40 pS and 60 pS on the same node add to 100 pS, or 0.1 nS, because parallel conductances sum. This is the form that matters for a high-impedance amplifier input, where the source resistance and the leak share the signal. Convert each leak to a conductance, add them, and compare the total with the source conductance in nanosiemens.
Series paths combine through resistance
Two conductances in series behave like two resistors in series. Two 200 pS paths in sequence, each equal to 5 gigaohms, make a 10 gigaohm path, which is 100 pS. The combined conductance is always smaller than the smaller of the two parts. Many recordings contain both cases: the pipette seal and a cell membrane in series, and several channels in parallel across that membrane. Writing everything in nanosiemens makes the parallel sums simple, while the series cases are easier in resistance. Switch between the two views with a reciprocal, and use this page to move the prefix when the sums are finished and the report needs a single unit.
Whole-cell values in nanosiemens
A small cell with a few nanosiemens of conductance has a membrane resistance of a few hundred megaohms. An illustrative cell at 2 nS corresponds to 2,000 pS and 500 megaohms. Opening a single channel of 25 pS adds only 1.25 percent to such a cell, which is why single-channel events can be seen on a quiet recording but not on a noisy one. The whole-cell value is also the sum of many channel types in different states, so it varies with voltage and time. When a paper reports a conductance in nS and another in pS, convert to one prefix before you compare their sizes, and state which one you used. Plot both on one axis only after the conversion, because a chart with mixed prefixes misleads the eye.
Digits, noise and instrument limits
The number you convert is only as good as the measurement behind it. Amplifier noise, pipette capacitance and temperature all change a conductance reading, and a value stated to five digits may be reliable to two. Rounding in this page follows the stored factor, so a difference between your hand calculation and the page usually traces to a mistyped exponent. Report the result with the same number of significant digits as the measurement, for example 0.15 nS and not 0.150000 nS. If a reading changes by a factor of ten when you repeat it, the problem lies in the setup and no unit conversion will help. Averaging several sweeps before you convert gives a steadier number than a single reading.
Symbols that need care
The symbols pS and nS use a lowercase prefix and a capital S. In lowercase, ps is a picosecond and ns a nanosecond, which are units of time and appear in the same recordings as sampling intervals. A table that lists both a sampling interval in ns and a conductance in nS can swallow a case error without complaint. Spell out the unit names in column headers. Spreadsheets also trip on the Greek mu and on the uppercase S in some fonts, so check pasted values. A reference case settles doubt quickly: 1 nS must return 1,000 pS, and 1 pS must return 0.001 nS.
Questions the conversion leaves open
The page does not tell you whether a seal is good enough, whether a channel is open or whether a leakage current meets a specification. It does not compute a conductance from a current and a voltage, and it does not convert resistance. Those steps come first, and the conversion only changes the prefix of the conductance you already have. The right acceptance level for a seal or a leakage figure comes from your protocol or the part datasheet. If your result seems off by a factor of one thousand, compare the unit symbols in the source with the ones selected on the page before looking for another cause. A table that lists a conductance in one prefix and a resistance in another is the usual place where such a slip hides.