Meter displays and low-level measurements

Handheld conductivity meters, aquarium and hydroponic testers and many lab probes read in microsiemens. Instruments that measure tiny leakage or single-channel conductance report picosiemens. When a measurement from one of the second kind has to be placed next to a reading from the first, the quickest route is to put both on one prefix. This page multiplies a picosiemens value by 10^-6 and gives microsiemens. It suits a student comparing a lab result with a handout, an engineer checking a probe against a datasheet, and anyone filling a table that mixes the two scales. The factor is exact, and the shift is six decimal places. Carry the unit symbol along with the number, since a table that shows only 0.25 will later be read as either a conductance or a conductivity.

A million picosiemens in one microsiemens

Pico is 10^-12 and micro is 10^-6, so one microsiemens equals 10^6 picosiemens. The formula is µS = pS × 1e-6. A conductance of 250,000 pS is 0.25 µS, 5 pS is 5 × 10^-6 µS, and 3,000,000 pS is 3 µS. Shifting the decimal six places to the left does it without a calculator. A resistance view gives a second check: one microsiemens is the reciprocal of one megaohm, so a path of 1 µS has 1 MΩ and a path of 1 pS has 1 TΩ. The SI Brochure defines the siemens as the reciprocal of the ohm and the prefixes as fixed powers of ten. A reading of 0.002 µS, for example, is 2,000 pS, which is 500 megaohms.

Ten picosiemens in microsiemens

The default 10 pS gives 1 × 10^-5 µS, or 0.00001 µS. In resistance terms that is 100 gigaohms, a very high isolation between two points, for instance between the input of a high-impedance probe and its guard. The result is small enough that no conductivity meter would display it, since a typical meter resolves a tenth of a microsiemens or more. The conversion therefore serves as a comparison between a measurement domain, where tiny conductances matter, and a screening domain, where only microsiemens-sized changes are visible. If the output is larger than your input, the pair of units is reversed.

From a cell constant to a conductance

A conductivity meter reports microsiemens per centimeter, which already includes a cell constant K in cm⁻¹. The raw conductance of the probe is the conductivity divided by K. With K = 1.0 cm⁻¹ in water at 1.5 µS/cm, the probe conductance is 1.5 µS, or 1,500,000 pS. Ultrapure water at 25 degrees Celsius has a conductivity near 0.055 µS/cm, and its conductance in a cell with K = 1.0 cm⁻¹ is 0.055 µS, which is 55,000 pS. This page does not handle the per-centimeter unit. Apply the cell constant yourself and then enter the conductance in siemens-based units.

Isolation between probe terminals

High-impedance measurements depend on leakage that is invisible on an ordinary meter. A leakage path of 20 pS corresponds to 2 × 10^-5 µS and to 50 gigaohms. Moisture, flux residue and dirt on a board can raise such a path by orders of magnitude, which is why guard rings and clean surfaces are used for electrometer inputs. Expressing the leakage in microsiemens makes it comparable with the conductance of the sample itself. If the sample conducts at 1 µS and the leakage is 20 pS, the leakage is one part in fifty thousand of the signal, small enough to ignore for most purposes. Cleaning and drying a board often changes the leakage by a larger factor than any instrument error does.

A megaohm resistor in picosiemens

A resistor of 1 MΩ has a conductance of 1 µS, which is 10^6 pS. A 200 kΩ resistor has 5 µS, or 5,000,000 pS. Resistors in the kilohm to megohm range are the bridge between the two prefixes: their conductances fall in the microsiemens range while a leakage or a channel falls in picosiemens. When you add the conductance of a leak in parallel with a resistor, convert the leak to the resistor unit first, then add. A 1 MΩ resistor with a 20 pS leak has 1.00002 µS in total, a change of 0.002 percent. A 10 MΩ resistor, at 0.1 µS or 100,000 pS, sees the same leak as a 0.02 percent change.

Case matters in unit symbols

The symbol pS has a lowercase p for pico and a capital S for siemens. A lowercase ps means picoseconds, a unit of time, and a capital PS is a metric horsepower in some catalogs. The prefix µ in µS is the Greek letter mu, and datasheets that cannot print it often write uS, which can be misread as microseconds in context. Spreadsheet headers that spell out picosiemens and microsiemens remove the doubt. Copying a value from a PDF, check the unit symbol twice, because a conversion between a conductance and a time would produce a meaningless number without any error message.

Checking a reading on the bench

A quick way to confirm a probe and a calculation is to measure a known standard. Conductivity calibration solutions are sold at values such as 84 µS/cm, 1,413 µS/cm and 12,880 µS/cm. With a cell constant of 1.0 cm⁻¹, a 1,413 µS/cm standard gives a probe conductance of 1,413 µS, which equals 1.413 × 10^9 pS. If the meter reads far from that value, suspect the cell constant, a dirty electrode or an expired solution before suspecting the unit conversion. The page converts what you enter and cannot verify the probe, so a known standard is the independent check that tells you whether the number deserves to be converted at all.

Temperature and cell effects stay outside

The page converts the prefix and nothing else. The conductivity of water rises by about two percent for every degree Celsius, and meters apply a temperature compensation to a reference temperature, usually 25 degrees. The conversion does not compensate for temperature, correct a cell constant, or judge whether a reading falls within a water-quality limit. Read those limits from the label of the standard or product you use, and enter the compensated figure if the comparison requires it. Applied consistently, the six-place shift keeps your tables aligned between sources. If you compare readings taken at different temperatures, bring them to the same reference temperature before converting, otherwise the comparison mixes a change in the water with a change in the unit. Record the temperature next to each conductance in your notes, together with the cell constant of the probe that produced the number, so that a later reader can reproduce the comparison.