Six decimal places at once

The step from micro to pico is a factor of one million. A value in µS becomes a number a million times larger in pS, so 10 µS is 10,000,000 pS. People rarely need such a conversion in everyday electronics, but it is common in the neuroscience lab, in electrometer work and in sensors with very small leakage. The page performs the shift without dropping zeros and works in the other direction as well. A result in pS that is much larger than the input is expected, and an unchanged number means the menus were not set.

Single ion channels in biology

Electrophysiologists use the patch-clamp technique to record the current through single ion channels in a cell membrane. The conductance of one open channel is given in picosiemens, with common values from a few pS to over 100 pS depending on the channel type. A channel of 20 pS equals 0.00002 µS. A whole-cell conductance, in contrast, may be in nS, and a population of cells in µS. A lab notebook that mixes these scales benefits from a conversion tool. Convert to a single unit before you divide a whole-cell conductance by a single-channel value to estimate the number of open channels. For instance, a whole-cell conductance of 2 nS, which is 2,000 pS, divided by a 20 pS channel suggests about 100 channels open at that moment. The result is an estimate, because channels flicker between states, the membrane has other conductances, and the recording has series resistance. Students learning the method often lose a factor of 1,000 at exactly this step, so write the unit beside each number.

Resistance in the teraohm range

One pS corresponds to a resistance of one teraohm, or 10^12 ohms. A conductance of 100 pS is 10 gigohms, and 5 pS is 200 gigohms. Electrometers and picoammeters measure such high resistances. When a data sheet lists an input resistance in teraohms, convert it to conductance in pS to compare it with a leakage figure in µS. For example, 0.0001 µS equals 100 pS, which matches 10 gigohms. The reciprocal view helps you decide whether a number is plausible for a clean, dry setup. Vendors of source-measure units and electrometers print input resistance and leakage in the specifications, so a quick table can help: 1 pS is 1 teraohm, 10 pS is 100 gigohms, 1,000 pS is 1 gigohm. Reading the specification in pS tells you directly how much parallel conductance the instrument adds to a sample, which then sets the lower limit on what you can resolve at the test voltage you plan to use.

Using the default of 10 µS

The default of 10 µS gives 10,000,000 pS. That is a huge number in this unit, equivalent to a resistance of 100 kilohms. If you see a result of this size in a pS context, the setup has a very low resistance, such as a short or a leak across the sensor. Typical pS measurements use inputs below 0.001 µS. For instance, 0.00002 µS equals 20 pS and 0.000005 µS equals 5 pS. Using small inputs shows how the page serves low-level work, and the default shows how large the multiplier is.

Shielding and guarding in the lab

To keep stray leakage from masking a pS measurement, instrument makers use guard rings, triaxial cables and clean insulators such as PTFE. The leakage of an ordinary insulating support can easily reach a few pS, which may be as large as the signal. When you compare a specification for a cable or a fixture, convert it to pS so it is on the same scale as your sample. A fixture leakage of 0.000001 µS equals 1 pS and might be acceptable for a 1 nS sample but not for a 10 pS sample.

Semiconductor and device characterization

Parametric analyzers record the off-state leakage of devices and the conductance of tiny structures such as nanowires. Data may come out in pS from the instrument and in µS in a report generated by software for larger devices. A nanostructure with a conductance of 3 pS is 0.000003 µS. When devices of very different size appear in one chart, use a logarithmic axis and a single prefix on the label. Converting before plotting avoids the common mistake of plotting two series with different unit labels on the same axis.

Reading and writing very small numbers

A number such as 0.000005 µS is hard to read, and 5 pS is easy. The prefix helps because the numeric part stays between 1 and 1,000. A good habit is to choose the prefix that gives such a number. In figure captions and slides, state the prefix once in the axis label, for example conductance (pS), and keep every tick label as a plain number in that unit. If a series needs a different prefix, give it its own panel or axis so that a reader never has to apply a factor of a thousand in their head. If you are using a spreadsheet, consider a custom format that shows the unit, or keep a column with the prefix name. Round to the precision of the measurement, which for most picosiemens work is two or three significant digits, even though the converter shows more.

Quick manual checks

Move the decimal point six places to the right when you go from µS to pS, and six places to the left for the reverse. Because six places is a lot, count in two groups of three, passing through nS. For example, 0.002 µS equals 2 nS equals 2,000 pS. This two-step view also explains why the page agrees with the µS to nS converter and the nS to pS step. Check one example whenever you work with a long chain of units. The same counting trick works for any pair of prefixes: milli to micro is three places, milli to nano is six, and milli to pico is nine, so a table with columns in three different prefixes can be checked row by row in a minute.

Boundaries of the tool

The converter changes the prefix of a conductance. It does not estimate leakage, judge an instrument for low-level work, or determine whether a measurement is free of noise, humidity or contamination. Results at the pS scale are sensitive to temperature, test voltage, cable motion and cleanliness. The number you convert is only as good as the measurement behind it, and the conditions of that measurement belong in your records.