Why picosiemens need converting
A picosiemens is one trillionth of a siemens, which makes it a unit for things that barely conduct at all. Datasheets for electrometer inputs, laboratory recordings from single protein channels and leakage specifications for insulating materials often quote conductance in pS, while circuit equations and simulation tools expect siemens or the reciprocal, ohms. Moving between the two by hand means counting twelve decimal places, and one slipped zero changes the answer by a factor of ten. This page does that bookkeeping. You enter a number, choose a source unit and a target unit from siemens, millisiemens, microsiemens, nanosiemens, picosiemens and kilosiemens, and the result appears as a plain number in the target unit. The default setting converts 10 pS to siemens, which gives 1e-11 S. The tool performs a unit conversion only. It does not know what is being measured, so it cannot tell you whether a given conductance is reasonable for a part or a sample.
The factor and the default example
Every unit in the list is a decimal multiple of the siemens, so the conversion is a power of ten. The pS to S factor is 1e-12, written in the formula as S = pS × 1e-12. With the default value of 10 pS, the product is 10 × 1e-12, which is 1e-11 S, or 0.00000000001 S. Going the other way divides by the same factor, so 1e-11 S entered as siemens and converted to picosiemens returns 10. Intermediate steps are easy to follow too. One picosiemens is 0.001 nanosiemens, 0.000001 microsiemens and 0.000000001 millisiemens. On the large side, one kilosiemens is 1,000 S, so one kilosiemens equals 1e15 pS. Results this small or this large are displayed in exponent notation, which is the same number written compactly. Read 1e-11 as 1 times ten to the power of minus eleven.
Conductance as the reciprocal of resistance
The siemens is the SI unit of electrical conductance, defined as one ampere per volt, which equals one reciprocal ohm. The 14th General Conference on Weights and Measures adopted the name in 1971 in honor of Werner von Siemens, and it replaced the older informal name mho for the same quantity. Because conductance G is 1 divided by resistance R, every picosiemens value has a resistance twin. One picosiemens equals one teraohm (1 TΩ), so the default 10 pS corresponds to 100 GΩ. That reciprocal view helps when a datasheet mixes the two styles. A leakage path of 10 pS across a 5 V supply carries I = G × V = 10e-12 × 5, or 50 pA. The same path described as 100 GΩ gives 5 divided by 1e11, which is again 50 pA. This converter does not take reciprocals. If you only have a resistance, convert it to conductance first with 1 divided by R.
Conductance is not conductivity
A common source of wrong answers is mixing conductance with conductivity. Conductance, in siemens, describes a specific object: this resistor, this cell, this length of wire. Conductivity, in siemens per meter, describes a material and does not depend on the shape of the sample. The two are linked through geometry: G equals conductivity times cross-sectional area divided by length. Ultrapure water at 25 °C has a conductivity near 0.055 µS/cm, which is 5.5e-6 S/m, and a conductivity probe reports that figure regardless of how large the probe cell is. The cell itself, with a fixed area and electrode spacing, has a conductance that you could express in microsiemens or nanosiemens. This converter changes prefixes on the siemens only. If the value on your datasheet carries a per-length unit such as µS/cm or mS/m, those are different quantities, and a plain prefix conversion here will not give the right answer.
Ion channels and patch-clamp recordings
Few fields use picosiemens as routinely as cell electrophysiology. When a patch-clamp pipette seals onto a small piece of membrane and isolates a single ion channel, the current that flows through the open channel at a known voltage gives the single-channel conductance directly. Reported values run from a few picosiemens to a few hundred, depending on the channel type and the ions involved. Erwin Neher and Bert Sakmann received the 1991 Nobel Prize in Physiology or Medicine for developing the technique. A channel with 25 pS conductance at a driving voltage of 60 mV carries 25e-12 × 0.060, or 1.5 pA, which is the scale that low-noise amplifiers are built to resolve. Papers sometimes report whole-cell conductance in nanosiemens, so a table that lists 0.5 nS and 500 pS for neighboring entries is describing the same size. Use the converter to put them on one unit before comparing.
Leakage paths in electronics
In circuits, picosiemens show up wherever something is meant to be an insulator. Printed circuit board surface contamination, flux residue, humidity on a bare board and the off-state of a transistor all behave like very high resistances in parallel with the intended signal path. Designers working with electrometer amplifiers, charge amplifiers, photodiode front ends or long-integration-time circuits care about these leaks because a few picosiemens at a few volts is a few tens of picoamps, which can swamp a femtoampere-level signal. Data sheets may express input leakage as a current, as a resistance in gigaohms or teraohms, or as a conductance. Putting everything in siemens makes them comparable. A path with 200 GΩ of insulation resistance has a conductance of 5 pS, since 1 divided by 2e11 is 5e-12. This page helps with the unit change. Whether the leakage is acceptable depends on the circuit, the temperature and the board cleaning process, none of which the converter knows about.
The prefix ladder on this page
The unit lists run through the common SI prefixes. Kilosiemens (kS) is 1e3 S, siemens is the base, millisiemens (mS) is 1e-3 S, microsiemens (µS) is 1e-6 S, nanosiemens (nS) is 1e-9 S and picosiemens (pS) is 1e-12 S. Each step in the sequence changes the value by a factor of 1,000, which gives a quick mental check: moving from pS to nS divides by 1,000, and moving from nS to µS divides by another 1,000. The BIPM SI Brochure and NIST Special Publication 811 describe these prefixes and require that they attach to the unit name without spaces or hyphens in the name. Note the capital S in the symbol, since a lowercase s means seconds. The micro symbol is the Greek letter mu, and a plain letter u is often substituted in plain text. A quick check on any result is to ask whether it moved in the right direction: converting to a smaller unit must make the number larger.
A second worked example
Suppose a noise measurement on a patch-clamp rig shows that the seal between pipette and membrane has a conductance of 250 pS, and the rig manual asks for the value in siemens. The conversion is 250 × 1e-12, which equals 2.5e-10 S, or 0.25 nS. As resistance that is 1 divided by 2.5e-10, or 4 GΩ, which clears the usual gigaseal target of at least 1 GΩ by a factor of four. A higher seal resistance means less leakage current around the channel being recorded. Now reverse the question. A datasheet quotes an input conductance of 3.2e-10 S, and you need picosiemens. Dividing by 1e-12 gives 320 pS. Entering 3.2e-10 in the value field, choosing siemens as the source and picosiemens as the target, returns 320. These figures are illustrative, not data from a particular instrument.
Reading very small results
Because picosiemens to siemens produces numbers with eleven or twelve leading zeros, a result is often displayed in exponent form. That notation is exact, and it is easier to compare than a long string of zeros. A result of 1e-11 is larger than 1e-12 by a factor of ten, even though both look tiny. When you copy a value into a spreadsheet or a SPICE netlist, check that the destination accepts e-notation. Most do, and SPICE also accepts engineering suffixes such as p for pico, though a lowercase m means milli in that tool and the suffix for mega is meg, which is a classic trap. When you report a result, choose the unit that keeps the number between about 0.1 and 1,000. Writing 10 pS is clearer than 1e-11 S for a reader who works in electrophysiology, and 1e-11 S is clearer for a reader who works in circuit simulation.
Scope of the conversion
The calculation is arithmetic on a unit prefix. It assumes the value you enter is already a true conductance, measured or specified under stated conditions, and it carries no information about those conditions. Real conductance in insulators depends on temperature, humidity, applied voltage and the time since the voltage was applied, so a figure quoted in a datasheet applies only at the stated settings. The converter does not calculate installation limits, equipment ratings, protection, material response or compliance with any standard. Treat the output as a rewrite of the number you supplied in a different unit, and check the original conditions in the source document. Nanoscale and biological conductances in particular carry measurement uncertainty that no unit conversion can remove, so keep the significant figures you were given rather than the many digits the page may display.
Measuring a picosiemens in practice
Nobody reads a picosiemens off an ordinary multimeter. The usual method is to apply a known voltage across the sample and measure the tiny current with a picoammeter or electrometer, then divide current by voltage. A 100 pA reading at 10 V means 10 pS. Several effects make this harder than the arithmetic suggests. Cables and connectors leak, so low-level setups use guarded triaxial cabling that keeps the leakage current away from the measured path. Insulators show dielectric absorption, so the current keeps drifting for seconds or minutes after the voltage is applied, and a reading taken after one minute differs from one taken after ten. Static charge, vibration and temperature changes add noise of their own. When a datasheet quotes a conductance in picosiemens, check the applied voltage and the waiting time before you rely on it, then use the converter for the unit change.