The question behind the conversion
A current of a few nanoamperes is what a quiet microcontroller draws in its deepest sleep state, and a current of a few microamperes is what the same chip draws when a low-power timer is running. Data sheets list both, often in different tables and sometimes in different units, and the person reading them has to decide which sleep mode saves more energy. This page puts the two on the same scale. You enter a current in nanoamperes and read it in microamperes, with a divisor of 1,000. The page also covers other current units, including amperes, milliamperes, picoamperes and femtoamperes. It changes only the unit of a current that you already know. It cannot tell you what current a circuit will draw, how a battery will behave or whether a conductor can carry a load.
The factor and the default example
Nano means one billionth and micro means one millionth, so 1 nA is 0.000000001 A and 1 µA is 0.000001 A. The ratio is 1,000, and since nano is the smaller prefix the number in microamperes is the smaller one. The formula on the page is µA = nA × 0.001. For the default input of 10 nA, the result is 10 × 0.001 = 0.01 µA. A current of 250 nA converts to 0.25 µA, and 4,700 nA converts to 4.7 µA. The last case shows a useful rule of thumb. Once a nanoampere figure passes about 1,000, it is more natural to quote it in microamperes. The conversion is exact, because both prefixes are defined as powers of ten in the International System of Units.
What an ampere is
The ampere is one of the seven base units of the SI. Since the 2019 revision, it is defined by fixing the value of the elementary charge at exactly 1.602176634 × 10^-19 coulomb. A current of one ampere is a flow of 1 coulomb per second, which is about 6.24 × 10^18 elementary charges every second. A nanoampere, by the same arithmetic, is about 6.24 × 10^9 elementary charges per second, or around 6.2 billion. That sounds like a lot, but it is a tiny flow compared with the currents of everyday devices. The BIPM SI Brochure gives the definition, and NIST Special Publication 811 lists the prefixes. Understanding the scale helps in interpreting why measuring nanoampere currents requires careful instruments and why stray leakage can be a significant error source.
Sleep current and coin cells
Battery life for small devices is mostly a question of sleep current. Take a device with a CR2032 coin cell, which is commonly rated at roughly 225 mAh. If the average current is 2 µA, which is 2,000 nA, the cell would in principle last 225 mAh divided by 0.002 mA, or 112,500 hours, about 12.8 years. In practice self-discharge, temperature, and the pulses from radio transmissions shorten that, so the figure is an upper bound. If instead the average current is 800 nA, the same arithmetic gives 0.8 µA, and the nominal lifetime is more than 32 years, which is clearly longer than the shelf life of the cell. These numbers are illustrations, not specifications of any product. They show how converting units makes a comparison straightforward.
A second example from a data sheet
Suppose a data sheet for a real-time clock chip lists a timekeeping current of 360 nA at 3 V, while a competitor lists 0.5 µA at the same voltage. To compare them, convert the first to microamperes: 360 nA times 0.001 is 0.36 µA, which is smaller than 0.5 µA. The first chip draws about 72 percent of the current of the second. Multiply the current by the voltage to get power: 0.36 µA at 3 V is 1.08 µW. The 0.5 µA chip is 1.5 µW. The figures are hypothetical and chosen to show the method. When two values are in different units, always convert before you compare, because a number like 360 can look bigger than 0.5 at a glance and mislead you.
Leakage currents
Many nanoampere figures in data sheets are leakage currents, which flow through a component that is supposed to be off or insulating. A reverse-biased diode, a capacitor, an input pin of an amplifier or a transistor in a switch each has some leakage. Typical values depend on temperature and voltage, and they often double for each rise of several degrees Celsius. For a precision circuit, a leakage of a few nanoamperes into a high-impedance node can cause a measurable offset. The voltage drop from 5 nA through 1 megohm is 5 mV, which is large compared with a microvolt-level signal. In microamperes the same leakage is 0.005 µA, a figure that looks negligible beside a signal quoted in microamperes yet still produces that 5 mV. The unit change does not alter the physics, so compare leakage and signal in one unit before deciding it can be ignored.
Measuring such small currents
A typical handheld multimeter does not resolve a nanoampere. Its lowest current range is often a few hundred microamperes with a resolution of 0.1 µA, and its burden voltage can disturb a low-power circuit. Measuring nanoamperes needs a source measure unit, a picoammeter or an electrometer, or a shunt resistor with a precision amplifier. Some engineers use a high-value resistor in series and measure the voltage across it, after which Ohm's law gives the current. For instance, a drop of 3 mV across 1 megohm corresponds to 3 nA, or 0.003 µA. Because the instrument range and unit change with scale, readings are often reported in microamperes when the meter is used on the low range, even if the data sheet quotes nanoamperes. This page translates between the two.
Reverse direction and neighboring units
To go from microamperes to nanoamperes, swap the units and multiply by 1,000. A reading of 0.01 µA returns 10 nA, and 2.5 µA is 2,500 nA. The converter offers milliamperes, amperes and kiloamperes at the large end, and picoamperes and femtoamperes at the small end, so you can also chain conversions. One milliampere is 1,000 µA and 1,000,000 nA, and one picoampere is 0.001 nA. The step from nA to pA is explained on a separate page. Keeping the sequence of milli, micro, nano, pico and femto in mind makes it easier to decide when a value needs a new prefix. A good habit is to choose the prefix that gives a number between 1 and 999, which reduces the chance of dropping a zero.
Common mistakes
A frequent slip is to multiply when you should divide. Remember that the number gets smaller when the unit gets larger, so nanoamperes to microamperes divides by 1,000. A second mistake is to mix up µA with mA, a factor of 1,000, which is the difference between a sleeping device and one that is actively running. Another is to read the symbol nA as ampere-hours or to confuse nanoamperes with nanoampere-hours. Finally, avoid carrying out calculations with currents and voltages in mixed units. Convert the current to amperes, the voltage to volts, then multiply to get watts. The converter does not do that for you, and the result is in the unit you choose.
Photodiode and sensor outputs
Many sensors speak in nanoamperes and microamperes. A photodiode amplifier may be fed from a diode that produces 40 nA in dim light and 3.2 µA in bright light, and the transimpedance stage turns that current into a voltage. With a 1 megohm feedback resistor, 40 nA gives 40 mV and 3.2 µA gives 3.2 V. Converting the dim reading, 40 nA is 0.04 µA, so a 100 times brighter condition, 4 µA, is 4,000 nA. Electrochemical gas sensors and glucose test strips also produce currents in the nanoampere to microampere range, and their readouts rely on accurate scaling. These are descriptions of typical orders of magnitude and not specifications. Check the sensor data sheet for the real range, since the output depends on the device, the conditions and the calibration.
Charge drawn over a day by a small current
A small current becomes an amount of charge over time. A load of 500 nA that runs for 24 hours draws 500 nA times 86,400 s, which is 0.0432 coulomb. In milliampere-hours that is 0.012 mAh, since 1 mAh is 3.6 coulombs. In microamperes the load is 0.5 µA, and the same day uses 12 µAh. Over a year, 365 days of 0.5 µA is 4.38 mAh, small enough that a 225 mAh cell would hold roughly 51 times more charge than needed. This kind of budget is typical for always-on timekeeping circuits. The values here are examples, and real systems add radio bursts, sensor reads and regulator losses. The conversion ensures that each part of the budget is in the same unit before the arithmetic starts.
Scope and sources
The page converts an electric current between SI-prefixed units. It does not calculate installation limits, equipment ratings, protection, material response or compliance, and it makes no claim about whether a given current is safe in a particular circuit or on a body. Those questions depend on the equipment, the voltage and the applicable code. The unit definitions come from the BIPM SI Brochure and the prefix list from NIST Special Publication 811. For design work, use the manufacturer data sheet and test conditions, which specify the temperature, supply voltage and state at which a quoted current is valid.