MEASUREMENT & METHODS

Watts (W): power unit guide

Watts provide the reference scale for power conversions.

Measurement basis

W describes a rate of energy transfer. Energy also needs the corresponding time relationship.

Definition conventions

Horsepower is mechanical unless marked metric. PS equals metric horsepower. Refrigeration tons use the US 12,000 BTU IT/h convention.

Conversion method

A W amount already uses the power reference. Divide by the receiving power factor for another target unit.

Reference equivalent of W

1 W = approximately 1 W.

Recorded scale factors: 1 for W; 1 for W.

Worked example

Known input: 10 W. Reference equivalent: 10 W. The return conversion gives approximately 10 W.

The watt reference example keeps the power magnitude unchanged and does not establish energy over an interval.

Common reference values

Input (W)Reference equivalent (W)
11
55
1010
2525
5050
100100

Compare one W with other units

Target unitEquivalent of 1 WDefinition guide
Kilowatts (kW)0.001Read definition
Megawatts (MW)0.000001Read definition
btu per hour (BTU IT/h)3.41214163313Read definition
Mechanical horsepower (hp mech)0.0013410220896Read definition
metric horsepower (hp metric)0.0013596216173Read definition
tons of refrigeration (TR)0.000284345136094Read definition
Nanowatts (nW)1000000000Read definition
Microwatts (µW)1000000Read definition

A joule every second

The watt, symbol W, is the SI unit of power. One watt is one joule of energy transferred per second, so 1 W = 1 J/s = 1 N m/s = 1 V A. In base units it is kg m² s⁻³. The unit is named after James Watt, the Scottish engineer who improved the steam engine, and the name was proposed by William Siemens in 1882. It is now one of the named derived units of the SI. Power is a rate, so a quantity in watts says how fast energy moves. It says nothing about how much energy is moved until a duration is given.

Prefixes and the converters on this site

Power spans many scales, and the site offers watts against nanowatts, microwatts, milliwatts, kilowatts, megawatts, gigawatts, terawatts and picowatts, as well as horsepower, Btu per hour and tons of refrigeration. A radio receiver may draw 50 mW, a laptop charger 65 W, an electric kettle 3 kW, a wind turbine 3 MW and a power station 1 GW. A sensor node that sleeps at a few microwatts and a plant at 10^9 W are 15 orders of magnitude apart. The factor from watts to kilowatts is 0.001, to megawatts 0.000001 and to milliwatts 1,000. Prefixes shift by powers of 1,000, so a misplaced prefix is a thousandfold error. Lowercase m means milli and uppercase M means mega, and the written symbol is the only guide.

Everyday loads in watts

A modern LED bulb gives the light of an old 60 W incandescent lamp at about 8 to 10 W. A laptop uses 45 to 65 W under load, and a microwave oven draws around 1,000 W. In the United Kingdom a 13 A plug on a 230 V supply can supply about 2,990 W, which is why many electric kettles are rated 3 kW. A 120 V circuit with a 15 A breaker supports 1,800 W of power, and heaters are often limited to 1,500 W so that the load stays within continuous rating. A resting adult dissipates about 80 to 100 W, since 2,000 kilocalories per day is 8.37 MJ over 86,400 s, or about 97 W.

Horsepower and Btu per hour

The mechanical horsepower, defined as 550 foot-pounds per second, is 745.69987 W. The metric horsepower, also called PS, is exactly 735.49875 W. One watt is 0.00134102 mechanical horsepower and 0.00135962 metric horsepower. A car engine rated at 100 kW therefore produces 134.1 mechanical hp, or 135.96 PS. Heating and cooling equipment uses Btu per hour, and 1 W is 3.41214 Btu/h. A 1,500 W heater delivers 5,118.2 Btu/h, or 2.0115 hp. The ton of refrigeration is 12,000 Btu/h, which equals 3,516.85 W. James Watt reportedly chose 33,000 foot-pounds per minute for a horse, which is how horsepower entered the units of power.

Real power, apparent power and reactive power

In alternating current circuits the product of RMS voltage and RMS current is the apparent power, measured in volt-amperes. Only part of it does work. The real power in watts is the apparent power times the power factor. A load drawing 10 A from a 230 V supply has 2,300 VA of apparent power, and at a power factor of 0.8 the real power is 1,840 W. Reactive power is in vars. Utilities bill large customers for kVA or for poor power factor, and generators and transformers are rated in kVA. The watt in a unit conversion refers to real power unless the source says otherwise, so keep the label with the figure.

Peak ratings on solar panels and sound systems

Some power ratings use special conditions. A solar panel labeled 400 W has that output under standard test conditions of 1,000 W/m² irradiance and 25 C cell temperature, and delivers less in typical field conditions, often written Wp for watt-peak. Audio amplifiers are rated in RMS watts into a stated load, while some marketing uses peak music power, a larger figure with little technical meaning. A rating tells the maximum or reference output and not the average, so a 5 kW solar array will not produce 5 kW all day. A 400 W panel with an area of 1.9 m² receives 1,900 W under the test irradiance, which makes its efficiency 21 percent. Converting a rating to horsepower or Btu per hour changes the unit and leaves its conditions unchanged.

Watts are not watts per hour

A common error is to write W/h or to say a 100 W bulb uses 100 watts per hour. A watt is already a rate. Energy used is power times time. A 100 W bulb running for 5 hours uses 500 watt-hours, which is 0.5 kilowatt-hours or 1.8 MJ. A power value says how fast energy flows at an instant, while an energy bill is about how long that flow lasted. A change of rate over time would be watts per second, which describes a ramp, and appears in grid and battery specifications. Watt-hours are covered separately on the site as an energy unit.

Heater, motor and air conditioner in watts

A 1,500 W space heater is 1.5 kW, 0.0015 MW, 1,500,000 mW, 2.0115 hp and 5,118.2 Btu/h. A 746 W motor is about 1 mechanical hp, and a 3 kW kettle is 4.02 hp. A 36,000 Btu/h air conditioner is 10.55 kW or 3 tons of refrigeration. A 250 mW radio transmitter is 0.25 W. A 2.4 GW nuclear plant is 2,400 MW and 2.4 x 10^9 W. Each step uses an exact or defined factor, so a result can be checked by hand to three digits. The converters list the pairs in both directions and apply the same factors.

Capital W and spacing for watts

Write W with a capital letter because the unit honors a person, and watt in lowercase when spelled out. Put a space between number and symbol, as in 60 W. The plural is watts. Do not use w, which is not a unit symbol, and avoid KW, since the kilo prefix is lowercase k. Quantity symbols for power are P, or Phi for radiant flux. Combinations such as kW h and kWh both appear for energy, and the product with a space or a raised dot follows SI style. Spelling out the unit in headings and keeping symbols in tables avoids confusion for readers who skim.

Precision and checking

  • Retain source power precision.
  • Keep rate and energy quantities separate.

Reference numbers are displayed with up to twelve significant digits. That display does not add precision to a rounded measurement. Keep source and target quantities compatible, confirm symbol case and regional conventions, and round the final result to precision justified by the input. Factors involving π or repeating fractions use finite numerical precision.

Use a working converter

Source and verification scope

The reference values and examples use the versioned unit definitions shared with the linked converters. Source dates identify the stated access or verification scope. A reverse calculation checks arithmetic and direction, but it does not independently verify a definition. Computandum is independent of the cited organizations, and the citations do not imply endorsement of this guide or a real application.

Sources

Read the calculation and sourcing methodology →