Measurement basis
One µW corresponds to 10^-6 W.
Definition conventions
Horsepower is mechanical unless marked metric. PS equals metric horsepower. Refrigeration tons use the US 12,000 BTU IT/h convention.
Conversion method
Multiply µW by 10^-6 for the reference.
Reference equivalent of µW
1 µW = approximately 0.000001 W.
Recorded scale factors: 1e-6 for µW; 1 for W.
Worked example
Known input: 10 µW. Reference equivalent: 0.00001 W. The return conversion gives approximately 10 µW.
The example retains the power quantity.
Common reference values
| Input (µW) | Reference equivalent (W) |
|---|---|
| 1 | 0.000001 |
| 5 | 0.000005 |
| 10 | 0.00001 |
| 25 | 0.000025 |
| 50 | 0.00005 |
| 100 | 0.0001 |
Compare one µW with other units
| Target unit | Equivalent of 1 µW | Definition guide |
|---|---|---|
| Watts (W) | 0.000001 | Read definition |
| Kilowatts (kW) | 1e-9 | Read definition |
| Megawatts (MW) | 1e-12 | Read definition |
| btu per hour (BTU IT/h) | 0.00000341214163313 | Read definition |
| Mechanical horsepower (hp mech) | 1.3410220896e-9 | Read definition |
| metric horsepower (hp metric) | 1.3596216173e-9 | Read definition |
| tons of refrigeration (TR) | 2.84345136094e-10 | Read definition |
| Nanowatts (nW) | 1000 | Read definition |
One millionth of a watt
The microwatt, symbol µW, equals 10⁻⁶ W. It combines the SI prefix micro (10⁻⁶) with the watt, the SI derived unit of power defined as one joule per second. The BIPM SI Brochure lists micro among the prefixes and gives µ as its symbol, the Greek letter mu. A microwatt is therefore one microjoule per second, and it takes a million of them to make one watt. The prefix names are fixed by the SI, so 1 µW is always 0.001 mW and always 1,000 nW. The site converter Watts to Microwatts applies µW = W × 1,000,000, which means 0.00025 W becomes 250 µW and 2 W becomes 2,000,000 µW. Only the decimal point moves, so no rounding is involved in any conversion between watts, milliwatts and microwatts.
Where the unit turns up
Microwatts describe devices that sip power for months or years. A quartz wristwatch movement draws on the order of a microwatt. Micropower sensors, remote controls in sleep mode, real-time clock chips and radio tags that wake briefly to transmit are usually specified in microwatts or in the equivalent microamperes at a stated supply voltage. Energy-harvesting designs matter here too: a small photovoltaic cell indoors, a thermoelectric element on a warm pipe or a vibration harvester typically delivers somewhere between a few microwatts and a few milliwatts, which sets the budget for a wireless node. In optics, a laser power meter reading of a few hundred microwatts is common when aligning a beam, and photodiode light levels are often quoted in the same range.
From current and voltage to microwatts
Electrical power is voltage times current, so a device on a 3 V supply that draws 2 µA uses 3 × 2 = 6 µW. A microcontroller that sleeps at 0.5 µA from 3.3 V draws 1.65 µW. These sleep figures matter because average power sets battery life. A CR2032 coin cell holds roughly 225 mAh at about 3 V, which is near 0.675 Wh, though datasheets vary by maker and load. At an illustrative constant 10 µW, that energy would last 0.675 Wh ÷ 0.00001 W = 67,500 hours, about 7.7 years, before any self-discharge or end-of-life voltage drop is counted. Real cells lose capacity at pulsed loads and low temperatures, so treat such a figure as an upper bound for planning, not a promise.
Reading radio power in microwatts and dBm
Radio receivers quote signal strength in dBm, decibels relative to one milliwatt. The link to microwatts is simple. 0 dBm is 1 mW, which is 1,000 µW. Each drop of 10 dB divides power by 10, so −10 dBm is 100 µW, −20 dBm is 10 µW and −30 dBm is 1 µW. A Wi-Fi client that sees −70 dBm is receiving 10⁻¹⁰ W, which is 0.0001 µW or 100 pW. Satellite navigation signals reach the ground at roughly −130 dBm, about 10⁻¹⁶ W. A very low-power transmitter, such as a Bluetooth Low Energy beacon set to −20 dBm, radiates 10 µW, while the signals that receivers actually decode usually fall far below a microwatt.
Budgeting a duty-cycled sensor node
Average power decides battery life, and microwatts make the budget easy to add up. Suppose, as an illustration, a node on a 3 V cell sleeps at 1 µA and wakes once a minute for a 5 ms radio burst at 10 mA. The burst contributes 10 mA × 0.005 s ÷ 60 s = 0.833 µA on average, so the node averages 1.833 µA, which is 5.5 µW at 3 V. The sleep current supplies more than half of that total even though the radio uses ten thousand times the current while it runs. Dividing a 225 mAh cell by 1.833 µA gives about 122,700 hours, or 14 years on paper. Leakage and the datasheet capacity at the real load shorten that, so the sleep current is the number to attack first.
Scale neighbors and what a day of 1 µW amounts to
Moving down the prefix ladder, 1 µW is 1,000 nW, 1,000,000 pW, 0.001 mW and 0.000001 W. Moving up, a thousand microwatts make a milliwatt. Power times time gives energy, which helps to judge how small the unit is. One microwatt sustained for a whole day delivers 10⁻⁶ W × 86,400 s = 0.0864 J. That is about 24 microwatt-hours, or 0.024 mWh. A single AA alkaline cell stores several thousand joules, so it could in principle supply 1 µW for many decades, which is why shelf life, not power draw, limits such designs. Comparing a 5 µW sensor with a 5 mW radio burst makes the same point: the radio transmitting for a tenth of a percent of the time still draws as much average power as the sensor.
Writing µW correctly
The SI symbol is a lowercase Greek mu followed by a capital W with no space between them. Unicode has both the micro sign (U+00B5) and the Greek small letter mu (U+03BC), and they look the same. Searching or sorting a spreadsheet can fail when the two are mixed, which is one reason many datasheets and plain-text files fall back on uW as a typed substitute. Datasheets also write µW/MHz for processor energy efficiency or µW/cm² for light intensity on a sensor. The prefix is case-sensitive: mW is milliwatt (10⁻³ W), MW is megawatt (10⁶ W), and µW is a thousand times smaller than mW. A reading mistyped as mW instead of µW is wrong by a factor of 1,000, so keep the complete symbol next to the number.
Confusions with other power and energy labels
Microwatts measure the rate of energy use, not the energy itself. A battery rating in mAh or Wh is a stored quantity, and a value in µW is a rate, so battery life needs both. Optical power can also appear as an irradiance, where µW/cm² describes power per area on a detector, and a bare µW describes total power in the beam. In audio and acoustics, power can be given in watts or decibels, and a microphone output is sensitivity, not power. Electrical power for AC circuits has real and apparent forms, and a meter reading in µW usually means real power in a small DC circuit. Note too that the site converter works on watts only. It does not know whether a number is peak, average or RMS, so keep that qualifier with the original reading.
Precision and checking
- Keep source power resolution.
- Preserve any measurement convention.
Reference numbers are displayed with up to twelve significant digits. That display does not add precision to a rounded measurement. Keep source and target quantities compatible, confirm symbol case and regional conventions, and round the final result to precision justified by the input. Factors involving π or repeating fractions use finite numerical precision.
Use a working converter
- Power converter
- Microwatts to Watts converter
- Microwatts to Kilowatts converter
- Microwatts to Megawatts converter
- Microwatts to btu per hour converter
- Microwatts to Mechanical horsepower converter
Source and verification scope
The reference values and examples use the versioned unit definitions shared with the linked converters. Source dates identify the stated access or verification scope. A reverse calculation checks arithmetic and direction, but it does not independently verify a definition. Computandum is independent of the cited organizations, and the citations do not imply endorsement of this guide or a real application.
Sources
- NIST / BIPM: NIST: unit conversion factors ↗ · 2026-10-08