MEASUREMENT & METHODS

Kilowatts (kW): power unit guide

Use kW for a known power rate expressed in kilowatts.

Measurement basis

A kilowatt corresponds to 1,000 watts.

Definition conventions

Horsepower is mechanical unless marked metric. PS equals metric horsepower. Refrigeration tons use the US 12,000 BTU IT/h convention.

Conversion method

Multiply kW by 1,000 to read W. Select another compatible power definition only after keeping the rate quantity clear.

Reference equivalent of kW

1 kW = approximately 1000 W.

Recorded scale factors: 1000 for kW; 1 for W.

Worked example

Known input: 10 kW. Reference equivalent: 10000 W. The return conversion gives approximately 10 kW.

The kilowatt example rescales a power value rather than an energy amount.

Common reference values

Input (kW)Reference equivalent (W)
11000
55000
1010000
2525000
5050000
100100000

Compare one kW with other units

Target unitEquivalent of 1 kWDefinition guide
Watts (W)1000Read definition
Megawatts (MW)0.001Read definition
btu per hour (BTU IT/h)3412.14163313Read definition
Mechanical horsepower (hp mech)1.3410220896Read definition
metric horsepower (hp metric)1.3596216173Read definition
tons of refrigeration (TR)0.284345136094Read definition
Nanowatts (nW)1000000000000Read definition
Microwatts (µW)1000000000Read definition

From Watt's engines to the SI watt

The watt is the SI unit of power, defined as one joule per second, 1 W = 1 J/s = 1 kg·m²/s³. It is named after James Watt, the Scottish engineer who improved the steam engine and who introduced the horsepower in the 1780s as a way of explaining the output of his engines compared with the draft horses they replaced. The mechanical horsepower is defined as 33,000 foot-pounds-force per minute, which is 745.69987158 W. The watt itself was adopted by the scientific community in the late nineteenth century and became part of the SI in the 1960s. A kilowatt is 1,000 W, a size matched to appliances, motors and building loads, where watts would give four- or five-digit numbers. The same prefix pattern gives the megawatt for power stations and the gigawatt for national grids.

Factors to horsepower, BTU per hour and tons of refrigeration

The converters for this unit use these factors: 1 kW = 1,000 W, 0.001 MW, 1.3596216173 metric horsepower (also written PS), 3,412.14163313 BTU IT/h and 0.284345136094 tons of refrigeration. In the opposite direction, 1 hp metric = 0.73549875 kW, 1 BTU IT/h = 0.000293071070172 kW and 1 TR = 3.51685284207 kW. Metric horsepower is exactly 75 kgf·m/s, which gives 735.49875 W. The mechanical horsepower used in the US is slightly larger at 745.69987158 W, so 1 kW = 1.34102209 mechanical hp, and the two horsepowers differ by about 1.4 percent. A 100 kW engine is 135.96 PS or 134.1 mechanical hp. A label that says only hp may refer to either one.

Household and workshop loads in kilowatts

A typical electric kettle draws 2 to 3 kW, and a UK 13 A plug on a 230 V supply can deliver at most 13 × 230 = 2,990 W, about 3 kW. A home EV charger on a single-phase 32 A circuit at 230 V delivers 7.36 kW, usually rated 7.4 kW. A three-phase 16 A, 400 V charger delivers √3 × 400 × 16 = 11.09 kW, rated 11 kW. An electric shower is commonly 8 to 10.5 kW, and a microwave oven may draw 1 to 1.5 kW from the wall while delivering less to the food. Solar panels are rated in watts, so a 400 W panel is 0.4 kW, and a 6 kW array has 15 of them. Many of these figures are nameplate ratings, and the average draw is lower than the rated value for most appliances.

Engine ratings and human output

Vehicle power is quoted in kW across most of the world and in hp in the US. A small hatchback with a 70 kW engine has 95.2 PS, and a performance car at 300 kW has 407.9 PS. Power at the wheels is lower than at the crankshaft because of drivetrain losses. Human power is small by comparison: a resting adult uses roughly 80 to 100 W as a whole body, while a fit cyclist can hold on the order of 200 to 300 W for an hour, or 0.2 to 0.3 kW, and short sprints reach several times that. A 0.25 kW rider needs 3,600 s × 250 W = 900,000 J, which is 0.25 kWh per hour. Those comparisons help set the scale of the unit, because a kilowatt is about what a person can produce for a few seconds.

Real power, apparent power and the power factor

In alternating-current systems, kW measures real power, the part that does work or produces heat. Apparent power is quoted in kVA, and the two are related by the power factor: kW = kVA × PF. A 50 kVA generator at a power factor of 0.8 delivers 40 kW. For a three-phase load, P = √3 × V × I × PF, so a 400 V circuit carrying 63 A at a power factor of 0.9 draws 1.732 × 400 × 63 × 0.9 = 39.28 kW. A heater is close to unity power factor, while an induction motor at partial load can be well below 0.8. A kW figure from a nameplate may be the shaft output rather than the electrical input, and the difference is the efficiency, so the same motor can have different kW values on its plate and on a meter.

Why a kilowatt is not a kilowatt-hour

A power rating describes a rate, and an energy quantity needs a time. One kilowatt sustained for one hour is one kilowatt-hour, which is 3.6 MJ. A 7.4 kW charger running for 5 hours delivers 37 kWh, and a 2 kW heater running for 30 minutes uses 1 kWh. The error of writing kW/h for the unit of energy is common on bills and in articles, and it describes a rate of change of power, which is a different quantity. When comparing a device label with a meter reading, the kW on the label tells how fast energy is used and the kWh on the meter tells how much has been used. Their relation is energy equals power times time, and each needs its own unit.

Heating and cooling: kW, BTU per hour and tons

Heating and air-conditioning equipment is rated in kW in most of the world and in BTU/h or tons in the US. One ton of refrigeration is 12,000 BTU/h, which is 3.51685 kW, so a 3.5 kW split air conditioner has 3.5 × 3,412.14 = 11,942 BTU/h, close to one ton. These are thermal output ratings, and the electrical input is a different value. A heat pump with a coefficient of performance of 3 delivers 3 kW of heat for 1 kW of electrical input, so a rating of 9 kW heating may be a 3 kW electrical load. The efficiency figure has to be read together with the thermal and electrical labels. A conversion of the thermal figure does not give the electrical consumption.

Writing kW correctly, and the kWp and kWth variants

The symbol is kW, with a lowercase k for the prefix and a capital W because the unit is named after a person. Writing KW or kw is common and understood, but it is nonstandard. The capital K in particular is the symbol for kelvin, not a prefix. Variants add a subscript or a letter to say what kind of power is meant: kWp is peak power, used for photovoltaic arrays under standard test conditions of 1,000 W/m² irradiance, kWe is electrical output and kWth is thermal output. A combined heat and power plant listed as 100 kWe and 150 kWth has two separate numbers, and the first does not include the second. Keeping the suffix with the value preserves the meaning when the kilowatt figure is converted into another power unit.

Precision and checking

  • Keep source power precision.
  • Retain kW with the number.

Reference numbers are displayed with up to twelve significant digits. That display does not add precision to a rounded measurement. Keep source and target quantities compatible, confirm symbol case and regional conventions, and round the final result to precision justified by the input. Factors involving π or repeating fractions use finite numerical precision.

Use a working converter

Source and verification scope

The reference values and examples use the versioned unit definitions shared with the linked converters. Source dates identify the stated access or verification scope. A reverse calculation checks arithmetic and direction, but it does not independently verify a definition. Computandum is independent of the cited organizations, and the citations do not imply endorsement of this guide or a real application.

Sources

Read the calculation and sourcing methodology →