From a datasheet to a power bill

Electricity is sold in kilowatt-hours, and appliances are rated in watts or kilowatts. Integrated circuits, radios and sensors are described in milliwatts and microwatts. Someone trying to work out what a connected gadget adds to a household bill needs the datasheet figure in kilowatts so it can be multiplied by hours and a price per kWh. This page performs that first step. Microwatts times 10^-9 gives kilowatts, and kilowatts times 10^9 gives microwatts. It converts units only. It does not read any meter, estimate a bill or assess the safety of a circuit, and the price per kilowatt-hour comes from your own tariff.

Prefix check

Micro is 10^-6 and kilo is 10^3 in the SI Brochure from the BIPM. A microwatt is therefore 10^-6 W, a kilowatt is 10^3 W, and the ratio is 10^-9. The formula is kW = µW × 1e-9. The default of 10 µW gives 1e-8 kW, and the page may show 9.999999999999999e-9 because of floating-point rounding, which is the same value. A billion microwatts make a kilowatt, so 1,000,000,000 µW is 1 kW. An easy memory aid is that micro to milli is three steps, milli to base is three, and base to kilo is three, nine places in all.

A year of standby

A device in standby that draws 0.5 W uses 500,000 µW, which converts to 0.0005 kW. Left on for the 8,760 hours in a year, that is 4.38 kWh, a small but real amount. At an illustrative price of 0.20 per kWh, the year costs 0.876, and dividing across many devices in a house gives a more meaningful total. A figure in microwatts is useful for sleeping electronics, such as a thermostat that wakes briefly, since those loads are far smaller than standby for a television. The method is always the same: convert to kilowatts, multiply by hours, multiply by the price.

Comparing a smart plug and a kettle

A kettle rated at 1,500 W is 1.5 kW, or 1,500,000,000 µW. A smart plug that draws 2.4 W for its own radio and relay uses 2,400,000 µW, which equals 0.0024 kW. Running continuously for a month of 730 hours, the plug adds about 1.75 kWh, while the kettle, used 10 minutes a day, takes about 7.5 kWh over the same period. Seeing the two on the same scale shows that the plug uses a visible share of what it controls, although each load is small. The page does not account for conversion losses or power factor, and for alternating-current loads the real power in watts is what applies here.

Rooftop solar and micro-scale harvesters

A home solar array is rated in kilowatts peak, for instance 5 kW, which is 5,000,000,000 µW. An energy-harvesting module on a small sensor may deliver tens or hundreds of microwatts, so the ratio between the two is about 10^7 to 10^9. Seeing both in one unit reminds a designer why an indoor harvester can run a sleeping radio but not a display backlight. The converter does not estimate how much a panel or a harvester will produce, which depends on light, orientation and wiring. It supports the unit comparison when product literature uses different scales for different parts.

Putting figures in a spreadsheet

A spreadsheet that lists loads in different units can use this page as a quick check on the conversion factor before the formula is entered. Take a known value, such as 2,500,000 µW, type it into the converter and confirm that the answer is 0.0025 kW. The same value is 2.5 W. Then use that factor, 1e-9, in a cell formula that handles the entire column. After that, add the loads, multiply by the hours of use and apply the tariff. Doing the check once avoids a silent error of a factor of 1,000 that would otherwise carry through the sheet and into any cost estimate. Label the column header with the unit, for example kW, so the next person who opens the file does not have to guess whether the figures are watts or kilowatts, and keep the source figure in its own column in case it has to be rechecked.

Reading very small outputs

Because the factor is so small, many inputs produce outputs in scientific notation. A value of 250 µW becomes 2.5e-7 kW, which is the same as 0.25 mW. A kW figure that small is rarely useful on its own, and you may prefer to show the load in watts or milliwatts in the report. Use the kW result when it is going into a formula with other kW values, such as a total load or an energy calculation, and the original unit when you describe the device. A table with one unit per column is easier to read than one with a mix of prefixes. As a worked case, an indoor air-quality sensor that averages 120 µW is 1.2e-7 kW, and over a year of 8,760 hours it uses about 0.00105 kWh, far less than a cent of electricity at any ordinary tariff.

Wearables and coin-cell budgets

Battery life is where microwatts and kilowatts meet in daily life. A coin cell rated 225 mAh at 3 V holds about 675 mWh of energy, which is 0.000675 kWh. A device averaging 15 µW, which is 1.5e-8 kW, would use that in 45,000 hours, a little over five years, if the cell delivered its full rated capacity, which real cells at that drain usually do not. The same arithmetic with a 150 µW average gives 4,500 hours, or about six months. The ratio of the two draws is ten, and so is the ratio of the lives. When a vendor quotes battery life, ask for the average power and the cell capacity used, and convert the average into one unit before checking the claim.

Power supplies, circuits and electricity bills

The page changes the unit of a power value and nothing more. It does not judge whether a circuit is safe, whether a power supply is adequate, or whether any installation rule applies, and it does not estimate bills, since those depend on usage and tariffs. The SI prefix definitions come from the BIPM and NIST SP 811, which are listed as sources. Displayed values are rounded, and very small results may show a floating-point tail in the final digits. Keep the original datasheet figure and its unit with any converted value.