MRI labels in tesla, stray-field notes in millitesla
Clinical MRI scanners are sold by field strength, and the familiar labels are 1.5 T and 3 T. The documents around a scanner mix prefixes. A siting drawing may describe the stray field at a corridor wall in millitesla, while a staff safety sheet may quote a boundary in gauss. A physicist laying out a room, or a technician comparing the scanner label with a vendor drawing, needs one unit for all of it. This page multiplies a tesla value by 1,000 and returns millitesla. Enter 1.5 and the answer is 1,500 mT, and enter 3 and the answer is 3,000 mT. The page changes only the number. Whether a given level is acceptable at a doorway is a decision for the site safety officer and the scanner vendor.
The factor behind the default of 10 T
The prefix milli means one thousandth, so 1 mT is 0.001 T and the formula is mT = T × 1000. The tesla is the SI unit of magnetic flux density, equal to one weber per square meter, and both the SI Brochure and NIST SP 811 list the prefix. The factor is a defined value, so the page adds no rounding of its own. It opens with 10 T and returns 10,000 mT. Ten teslas is a research-magnet figure, well above any clinical scanner, so read the default as a demonstration. A value of 0.45 T gives 450 mT and a value of 0.2 T gives 200 mT. If the answer comes out smaller than your input, the units were chosen in the wrong order.
Neodymium magnet datasheets
Magnet suppliers publish a remanence figure, usually written Br, for each grade. Sintered neodymium grades are commonly listed between about 1.1 T and 1.4 T, and some catalogs print the same figure as 1,100 to 1,400 mT. A grade listed at 1.32 T is 1,320 mT. Someone who buys a magnet and then probes it with a handheld gaussmeter that reads in millitesla will find a much lower number at the surface, because the field of a real magnet depends on its shape, its thickness and the distance to the probe. Remanence is a material property of the grade, and the surface reading is a property of the finished part. The converter helps you put both on the same scale without implying they should match.
Hall sensors and their measuring range
Linear Hall sensors and magnetic encoders list a sensitivity in millivolts per millitesla and a measuring range in millitesla. A designer who knows the field of a small magnet in teslas has to restate it before checking the range. As an illustration, take a sensor with a range of plus or minus 100 mT. A field of 0.2 T is 200 mT, so the output would saturate, while a field of 0.05 T is 50 mT and sits inside the range. Datasheets also state the temperature at which the sensitivity was measured, and magnet strength itself drifts with temperature. The converter handles the unit. Range, offset and drift stay with the datasheet of the part you chose.
Gauss still appears on gaussmeters and catalogs
Many magnet catalogs, older gaussmeters and some safety signs use gauss. One gauss is 0.0001 T, so 1 T is 10,000 G and 1 mT is 10 G. A reading of 50 mT is 500 G, and 0.45 T is 4,500 G. MRI safety documents often mark the 5 gauss line as the point beyond which people with certain implants are kept out, and 5 G is 0.5 mT. The unit menus on this page include gauss, so you can switch the target and read the same value in gauss without a second tool. Because a gauss is smaller than a millitesla, the number gets larger when you go from mT to G, and smaller when you go the other way.
Earth's field and a phone compass
The geomagnetic field at the surface of the Earth is roughly 25 to 65 microtesla depending on location, which is 0.025 to 0.065 mT. That puts a phone compass and a bench magnet on very different footings. A stray field of 2.5 mT near the magnet of a loudspeaker is about fifty times a typical 50 µT background, which is why a compass needle swings when it sits beside one. Converting both figures to millitesla makes that comparison immediate: 50 µT is 0.05 mT, and 2.5 mT divided by 0.05 mT is 50. Anyone calibrating a magnetometer app or checking a build for magnetic interference can use the same step to see how much headroom the sensor has.
Going from millitesla back to tesla
Select milliteslas as the source and teslas as the target to reverse the step. A coil described as producing 2.5 mT gives 0.0025 T, and a pulsed field of 800 mT gives 0.8 T. Papers on electromagnets, magnetic separators and small motors frequently quote millitesla in the text and tesla in the figure axis, so a reader who tries to reproduce a plot has to move between them. The factor is the same in both directions, 1,000, and the page applies it as a division when the source is the smaller unit. Writing the target unit directly beside every converted figure in your notes, for example 0.8 T (800 mT), keeps later readers from guessing which scale a column used.
Lab electromagnets and the units on their power supplies
Teaching labs and small research groups often run an electromagnet whose manual gives the gap field in millitesla for a stated coil current, for example 300 mT at some current, while the experiment write-up asks for teslas. Converting 300 mT back to 0.3 T is simple, but a mix of units in one table is how mistakes enter lab reports. A good habit is to choose one unit for the whole data sheet and convert every entry once. Hall probes on a bench teslameter frequently switch ranges between 0.3 T and 3 T full scale, and the display may change its prefix when it does. Read the unit shown beside the digits each time you note a result.
Flux density B is not field strength H
The tesla and millitesla measure magnetic flux density, B. Magnetic field strength, H, is measured in amperes per meter, and the two are linked by the permeability of the material, which differs for air, iron and a ferrite core. This converter rescales a B value and does nothing more. It does not estimate the pull of a magnet, the field inside a coil from its current, or the effect of a steel plate nearby. It also says nothing about exposure limits for people or about the rating of any equipment. Write the symbol as mT with a lowercase m, because capital M would mean megatesla, a factor of one billion larger.