Six places between a phone and a lab sensor

Everyday magnetometers work in µT. The most sensitive sensors, such as SQUIDs and optically pumped magnetometers, resolve fields in picoteslas or lower. Going from µT to pT multiplies by one million, so 10 µT becomes 10,000,000 pT. The converter keeps those zeros straight and works in the reverse direction. A datasheet that lists noise in pT and a reading in µT can be compared once both are in one unit. The prefixes come from the BIPM SI Brochure, which makes the factor exact.

Biomagnetic signals

The heart and the brain generate magnetic fields that sensors can record outside the body. Cardiac fields are of the order of tens of picoteslas, and fields from brain activity are smaller, in the femtotesla range, which is thousandths of a picotesla. A background field of 50 µT, which equals 50,000,000 pT, is millions of times larger. This is why such measurements take place in magnetically shielded rooms and use gradiometers. When you read a paper that states a signal in pT and a room background in µT, convert them to the same unit to see the ratio. A signal of 50 pT against a 50 µT background is one part in a million. A gradiometer helps because it subtracts the field seen by two nearby sensors, so a distant disturbance that appears in both cancels, while a nearby source such as the chest appears mostly in the closer sensor. Hospitals and research centers that run such systems also keep lifts, trams and parked vehicles in mind when they choose the site.

Reading noise specifications

Low-noise magnetometers list noise density in pT per root hertz. A sensor with 100 pT per root hertz has a noise density of 0.0001 µT per root hertz. A sensor with 1 nT per root hertz, equal to 1,000 pT, is ten times noisier. When two data sheets use different prefixes, a table in pT shows the ranking directly. Remember that noise density depends on frequency, and that integrating over a bandwidth gives the RMS noise, so a comparison needs the same bandwidth in both cases. For a rough estimate, multiply the noise density by the square root of the bandwidth in hertz: 100 pT per root hertz over 100 Hz gives about 1,000 pT RMS, which is 0.001 µT. A sensor sold for compass use may list its noise in µT instead, and converting both to pT shows at a glance that the research sensor is thousands of times quieter, although it also costs far more and needs more care in use.

The default value

The default 10 µT equals 10,000,000 pT. It would be large input for a precision sensor, which often saturates or has a range of a few µT at most. Smaller examples show what the page is for: 0.001 µT equals 1,000 pT, 0.0002 µT equals 200 pT, and 0.00005 µT equals 50 pT. At those levels, the surrounding environment matters. Moving vehicles, elevators and power lines can disturb a measurement by many nT, which is thousands of pT, and one reason low-noise work is done in shielded locations. Even in a quiet laboratory the sensor sees the field of the building steel, the cables and the equipment on the bench, so it is common to measure the background first, with the experiment switched off, and subtract it. A background that changes by 2,000 pT during a ten minute run would hide a signal of 200 pT, which is why long recordings are split into short segments and checked for drift in the same unit as the signal.

Magnetic shielding and background

A mu-metal shield can reduce a static background by a large factor, and a shielded room built for biomagnetic work can bring the residual field down to the nT range or lower. If the shield reduces 50 µT to 5 nT, that is a factor of 10,000. In pT the residual is 5,000 pT. The shielding factor depends on frequency and on how the shield is built and demagnetized. Specifications in the room documentation use a mix of µT, nT and pT, and a conversion helps check that all are consistent. A shielded enclosure also has an opening for people and cables, and the field near the door can be several times higher than at the center, so the rating applies to a stated region. Before you place a sensor, map the residual field at a few points with a fluxgate magnetometer, convert the readings to pT, and choose the position where the value is lowest and steadiest. Record the date, because the residual field changes if the shield is moved or magnetized by a nearby magnet.

Teaching and calibration labs

Calibration laboratories generate known fields in coils and compare sensors against them. A calibration certificate may state the uncertainty as a fraction of the field or in absolute terms in pT. For a 50 µT test field with a relative uncertainty of 0.01 percent, the absolute uncertainty is 5 nT, which is 5,000 pT. Expressing the uncertainty in the same unit as the sensor resolution shows whether the calibration is good enough for the use you have in mind. A relative uncertainty is convenient at one field value but may not apply across a range, because offsets and noise add an absolute floor. A sensor calibrated at 50 µT with a good relative uncertainty can still be unreliable at 200 pT, where a floor of 20 pT is already ten percent. Ask for the uncertainty at the field you will use, and convert it to the unit you plan to report.

Digits and scientific notation

A number like 10,000,000 pT is easy to misread. Scientific notation, 1 × 10^7 pT, or a different prefix such as 10,000 nT, can be clearer. Choose the unit that keeps the numerical part between 1 and 1,000 for the quantity you discuss. In a paper, state the prefix in each axis label and avoid mixing units on one axis. If you use software that parses units, test a few conversions against this page before trusting a long pipeline.

Manual checks

Move the decimal point six places to the right to go from µT to pT. A reading of 0.0002 µT becomes 200 pT, and 2.5 µT becomes 2,500,000 pT. A quick way is to convert through nT: multiply by 1,000, then by 1,000 again. If you work from pT to µT, divide by 1,000,000. The two-step check is easy to do mentally and catches the most common mistake, which is moving the decimal point by three places instead of six.

Picotesla signals and sensor noise

The page changes the unit of a flux density value. It does not tell you whether a sensor is suitable, whether a signal can be recovered from noise or how to design a shield. Those need an understanding of the measurement system and its calibration. Use the page to put numbers on a common scale, and use the instrument documentation and the relevant literature to decide what the numbers mean.