Gauss meters and tesla specifications

Handheld magnetic field meters, especially those sold for surveying household appliances and wiring, often display milligauss. Scientific papers, product data sheets and international standards use teslas and their prefixes. A reader who wants to compare a meter reading with a published value has to bridge the two. This converter takes a flux density in milligauss and returns milliteslas. A reading of 500 mG becomes 0.05 mT, which is a value that can be compared directly with a magnet specification or with the Earth's field in the same unit. The page changes the unit of a flux density you already know. It does not decide whether a field is harmful, and it cannot tell you what a meter would read at another distance or orientation. Because the factor is a pure power of ten, a result can be checked by eye, which makes the page a handy test for a column of readings.

Where the factor 0.0001 comes from

The gauss is a unit from the CGS system, and one gauss is defined as exactly 10⁻⁴ tesla. A milligauss is a thousandth of that, 10⁻⁷ T. A millitesla is 10⁻³ T. Dividing 10⁻⁷ by 10⁻³ gives 10⁻⁴, so each milligauss equals 0.0001 mT, as the page formula states: mT = mG × 0.000100000000000. The prefixes milli and the relation of gauss to tesla are exact, so the factor has no uncertainty. A useful shortcut: 10 mG equals 1 µT, and 10,000 mG equals 1 mT. Moving from milligauss to millitesla shifts the decimal point four places to the left. Going the other way, from millitesla to milligauss, shifts it four places to the right. Those four places are the most common stumbling point, so check them carefully. As a memory aid, a gauss is a tenth of a millitesla, and a milligauss is a thousandth of that.

The default example

With the default 10 mG, the converter returns 0.001 mT. That is the same as 1 µT, 0.000001 T or 0.01 G. A quick check: 10 mG is 0.01 G, and 0.01 G times 0.1 mT per gauss equals 0.001 mT. If the page showed 0.01 or 0.0001, the decimal shift was off by one place. The default is a field level that typical household appliances can reach at close range, though actual readings depend on the device, its load and the distance. It is also much smaller than the Earth's field of 250 to 650 mG. The comparison helps put the default into perspective: the planetary field is dozens of times stronger than a typical default reading, and much stronger than most readings away from equipment. On a scale of exponents, 10 mG is 10⁻⁶ T, so the same number is 1 µT, which makes a convenient bridge to the microtesla units used on phone sensors.

History of the gauss and the tesla

The gauss honors Carl Friedrich Gauss, whose work in the 1830s established absolute measurements of magnetism. It became the standard unit of flux density in the centimeter-gram-second system. The tesla, named for Nikola Tesla, was adopted into the International System of Units by the General Conference on Weights and Measures in 1960. In SI the tesla is one weber per square meter, with weber being the unit of magnetic flux. Because one gauss is 10⁻⁴ tesla, a tesla is 10,000 gauss. Research in physics and engineering moved to the tesla, but the gauss survived in several industries, partly because the numbers in gauss are convenient at the weak fields of everyday life and partly because instruments in the field kept the unit. That is why the conversion still matters. The weber, the unit of magnetic flux, is named for Wilhelm Weber, who worked with Gauss on magnetism in Göttingen, and the maxwell is the CGS flux unit that corresponds to 10⁻⁸ Wb.

How standards treat the gauss

NIST Special Publication 811 lists the gauss among units that are not part of the SI and gives the exact relation 1 G = 10⁻⁴ T. The BIPM SI Brochure does not include the gauss among the units accepted for use with the SI, which means that formal documents should state values in teslas. In practice, many instruments keep the gauss as a display option. When you prepare a report, cite the original value and unit alongside the conversion. For example, write 500 mG (0.05 mT), so that readers can see both the instrument reading and the SI value. Using the SI value in calculations avoids problems, because formulas for forces on charges and currents are written for teslas. A force on a moving charge, for instance, is qvB, with B in teslas and the force in newtons.

Household fields in milligauss

Surveys of household magnetic fields from power wiring and appliances report values in milligauss, and typical readings away from appliances fall in a range from a fraction of a milligauss to a few milligauss, with higher values very close to motors, transformers and heating elements. The field falls off quickly with distance from a small source, so readings taken at different distances can differ by large factors. Fields at 50 or 60 Hz are alternating, and meters usually report an RMS value. A reading of 2 mG converts to 0.0002 mT or 0.2 µT. These are general descriptions and not measurements of any home. If you take your own readings, record the position, orientation, distance and the instrument model. The conversion gives the same physical quantity in a different unit, and it cannot make a poorly documented measurement more reliable. Appliances with motors or heating elements usually show a stronger field at the surface than a wall outlet does, but the field falls off over a few tens of centimeters.

Guideline levels and what this page cannot decide

Public exposure guidelines for low-frequency magnetic fields exist. The ICNIRP 2010 guidelines, for example, give a reference level for the general public of 200 µT at 50 and 60 Hz, which equals 2,000 mG or 0.2 mT. Those values refer to specific frequencies and measurement conditions, and the guidelines explain how they are applied. This page does not evaluate exposure or compliance. It converts a number from one unit to another. If you are comparing a measured value with a guideline, make sure the frequency, averaging method and measurement position match what the guideline requires, and consult the document itself or a qualified professional. A conversion from milligauss to millitesla is only a first step in such a comparison, and it does not replace the interpretation that the guideline requires.

The Earth's field in milligauss

Earth's field at the surface ranges from roughly 250 to 650 mG depending on location, which is 0.025 to 0.065 mT or 25 to 65 µT. A common mid-latitude value is 500 mG, which converts to 0.05 mT. The field is weakest near the equator over parts of South America and strongest near the magnetic poles. It is a static field, and it changes slowly over years. A magnetometer near a steel desk or a speaker reads differently from one outdoors, because nearby ferromagnetic material distorts the field. Comparing an indoor reading of 800 mG with the 500 mG outdoor value tells you that the local environment adds to or redirects the field. Converting both to millitesla, 0.08 mT and 0.05 mT, makes the comparison compatible with data sheets for sensors and magnets.

Worked examples

Convert 500 mG: multiply by 0.0001 to get 0.05 mT. Convert 2 mG: the result is 0.0002 mT. Convert 1,000 mG, which is 1 G: the result is 0.1 mT. For the reverse direction, 0.001 mT equals 10 mG, found by swapping the units and entering 0.001. A round trip from 500 mG to millitesla and back returns 500 mG, subject only to floating-point noise in the last digits. Another check goes through teslas: 500 mG is 0.5 G, which is 0.5 × 10⁻⁴ T, or 5 × 10⁻⁵ T, and that is 0.05 mT. Such multi-step routes are slower than the converter, but they confirm that the decimal shift is right.

Reading meters correctly

Single-axis meters measure the field component along one direction, and the reading depends on how the probe is oriented. Three-axis meters combine the components into a vector magnitude, which is the right quantity to compare with most limits. The response of a meter to frequency also varies: some are designed for 50 and 60 Hz, others for a wider band, and a reading outside the design band may be wrong. Meters have specified accuracies, often a few percent, and they may need calibration. When you report a converted value, indicate the number of significant digits that the meter supports. A reading of 1.2 mG with a meter that resolves to 0.1 mG has two significant digits, so 0.00012 mT is the fair expression, not 0.000120000 mT. The conversion carries no uncertainty of its own. Averaging over a measurement period smooths out short fluctuations, and a meter set to hold the maximum reading reports something different from one that shows the instantaneous value.

Scope of the page

The converter expresses a known magnetic flux density in a different unit. It does not calculate installation limits, equipment ratings, protection, material response or compliance, and it does not judge whether a field is acceptable for people, implants or equipment. Those questions depend on standards, frequency, duration and the application, and they belong to qualified professionals. For the definitions, see NIST Special Publication 811 and the BIPM SI Brochure. Use the page to avoid slips in the decimal point, and keep the original instrument unit next to every converted value. The factor is exact, so a result that differs from another tool by a power of ten usually comes from a missed decimal shift.