Why gaussmeters still read in milligauss
Handheld gaussmeters sold for checking fields around wiring, appliances and electronics often display milligauss, a habit that persists in the United States from older survey practice. Newer instruments and research sensors use microteslas, nanoteslas and picoteslas. Someone who compares a home survey made with a milligauss meter against a sensor datasheet needs both on one scale. This page multiplies a picotesla value by 10^-5 and returns milligauss. The factor is small enough that the result of a typical sensor noise figure comes out as a tiny decimal, which the page shows in scientific notation for readability. Records kept in milligauss stay usable, because the conversion is a fixed factor that can be applied at any time.
A milligauss in tesla terms
One gauss is 10^-4 T and one milligauss is a thousandth of that, 10^-7 T, which is 0.1 µT or 100,000 pT. The formula is mG = pT × 1e-5, and the factor is exact. A field of 200,000 pT is 2 mG, a field of 50,000,000 pT is 500 mG, and a field of 1 pT is 1 × 10^-5 mG. The milligauss belongs to the CGS family that NIST SP 811 lists outside the SI. A useful shortcut ties it to the microtesla: 1 µT equals 10 mG, so a meter that reads in milligauss shows ten times the number you would see in microteslas. That is the same as saying that 1 mG is 0.1 µT, so a 3 mG reading is 0.3 µT.
Ten picoteslas in milligauss
The page opens with 10 pT and returns 1 × 10^-4 mG, or 0.0001 mG. A gaussmeter with a resolution of 0.1 mG, which is typical for inexpensive models, would not show a change that small, and 10 pT is a thousand times below that resolution. The comparison tells you what each class of instrument sees: the household meter shows fields from a fraction of a milligauss upward, while a research sensor resolves picoteslas, which are thousandths of that step. If the page returns a number larger than your input, the two units were selected in the wrong order. A research sensor with a noise floor of 1 nT, which is 1,000 pT or 0.01 mG, resolves a tenth of the display step of that household meter.
Reading a meter beside an appliance
A field meter held near a power cord, a transformer or a hair dryer shows a number that depends strongly on distance, because alternating fields from a source fall off quickly as you move away. A reading of 2 mG at one position equals 0.2 µT and 200,000 pT. A reading of 20 mG, which can occur very close to some appliances, equals 2,000,000 pT. When you write down a survey, record the distance, the position, the appliance state and the frequency band of the meter. Without those details the milligauss number has little meaning for anyone who reads the notes later. Photograph the meter position if you can, because moving from 10 cm to 30 cm from a source can change the number by a large factor.
Milligauss to microtesla in one step
The shortest conversion links the two common units: divide milligauss by 10 to get microteslas. A reading of 2 mG is 0.2 µT, 10 mG is 1 µT, and 500 mG is 50 µT. That ratio makes quick comparisons with published fields easy, since planetary field values are usually given in microteslas. The page performs the same arithmetic for picoteslas and milligauss, which are five decades apart, and is useful when a sensor noise figure in picoteslas has to be compared with a meter resolution in milligauss. Always carry the unit symbol next to the number, because mG and µT look alike in a table.
The planetary field in milligauss
A compass needle responds to a field of about 0.5 G in many places, which is 500 mG, 50 µT and 5 × 10^7 pT. A milligauss meter near a laptop, a speaker magnet or a steel desk will show changes of tens or hundreds of milligauss on top of that background, which is why a household meter held close to metal objects gives readings that drift. For a power-frequency survey the meter filters the signal to the line frequency, which removes the static planetary field, so a reading of 1 mG means an alternating field of that size. A static field needs a different probe and a different meter.
Recording a survey so it can be repeated
A reading in milligauss is repeatable only with its context. Note the date, the meter model, the frequency range it covers, the distance from each source and whether the display shows an average, a maximum or an rms value. Measure at the same points under the same load conditions if you want to compare before and after a change such as moving a charger. Convert to microteslas or picoteslas only at the reporting stage, when you need to compare with a sensor datasheet, and keep the original milligauss readings in the appendix of the notes.
From milligauss to picoteslas
Choose milligauss as the source and picoteslas as the target to reverse the step. One milligauss is 100,000 pT, 0.5 mG is 50,000 pT, and 20 mG is 2,000,000 pT. A noise floor of 100 pT on a sensor datasheet corresponds to 0.001 mG, so the sensor resolves a thousand times below the 1 mG display step of many handheld meters. Converting the display step of your meter to picoteslas, and the noise figure of the sensor to milligauss, makes the comparison direct. Neither direction needs more than the factor of 10^5. For a larger example, 150 mG is 1.5 × 10^7 pT, or 15 µT.
Meter accuracy and exposure guidance
The page converts a flux density and nothing more. It cannot say whether a reading is within an exposure guideline, which depends on frequency, duration and the standard you apply, nor whether a meter is calibrated. Inexpensive meters have limited accuracy and a narrow frequency response, and readings near sources vary with orientation. If a result matters for a decision about a workplace, a medical device or a building, use a calibrated instrument and refer to the applicable standard or a qualified professional. The converter simply keeps the numbers consistent across sources. Keep the milligauss reading and the converted value together, so anyone can see which one came from the instrument.