Measurement basis
Its reference factor is 1/3,600 kg/s, stored with finite precision.
Definition conventions
Pounds use avoirdupois mass. A mass-flow unit conversion does not supply the density needed for a volume-flow relationship.
Conversion method
Divide kg/h by 3,600 to read kg/s.
Reference equivalent of kg/h
1 kg/h = approximately 0.000277777777778 kg/s.
Recorded scale factors: 0.00027777777777777777777777777777777777777777777777778 for kg/h; 1 for kg/s.
Worked example
Known input: 10 kg/h. Reference equivalent: 0.00277777777778 kg/s. The return conversion gives approximately 10 kg/h.
The example changes the time basis without changing mass.
Common reference values
| Input (kg/h) | Reference equivalent (kg/s) |
|---|---|
| 1 | 0.000277777777778 |
| 5 | 0.00138888888889 |
| 10 | 0.00277777777778 |
| 25 | 0.00694444444444 |
| 50 | 0.0138888888889 |
| 100 | 0.0277777777778 |
Compare one kg/h with other units
| Target unit | Equivalent of 1 kg/h | Definition guide |
|---|---|---|
| Kilograms per second (kg/s) | 0.000277777777778 | Read definition |
| Grams per second (g/s) | 0.277777777778 | Read definition |
| Grams per minute (g/min) | 16.6666666667 | Read definition |
| Pounds per second (lb/s) | 0.000612395172736 | Read definition |
| Pounds per hour (lb/h) | 2.20462262185 | Read definition |
A mass flow counted by the hour
A kilogram per hour (kg/h) is a mass flow rate, the amount of mass passing a point or produced each hour. The hour is not an SI unit, but the SI Brochure accepts it for use with the SI, with 1 h equal to 3,600 s. The coherent SI unit of mass flow is kg/s, so 1 kg/h equals 1/3,600 kg/s, or 0.000277778 kg/s. Hours are a natural time base for process plants, boilers, feeders and engines, where outputs run for shifts and are reported per hour. The unit tells you the rate, not the total. To get a total, multiply by the number of hours, so a feeder running at 120 kg/h for a 24 hour day moves 2,880 kg.
Industries that quote kg/h
Steam boilers are rated by the steam they produce, often in kg/h or tonnes per hour, with a small industrial boiler making a few thousand kg/h. Plastic extruders and compounding lines quote throughput in kg/h, and food and chemical plants rate feeders and dryers the same way. Engine data sheets give fuel consumption in kg/h, which engineers prefer to volume because fuel mass is unaffected by temperature. A gas turbine burning 800 kg/h of fuel uses 0.2222 kg/s. Air-conditioning refrigerant circuits, pharmaceutical dosing, wastewater sludge handling and mining conveyors also use the unit.
Steam, fuel and throughput in kg/h terms
Rates in kg/h connect to energy through the property of the material moved. Steam leaving a boiler at 5,000 kg/h needs on the order of 2,300 to 2,700 kJ added per kilogram, depending on feedwater temperature and pressure, so a boiler making 5,000 kg/h supplies roughly 3.2 to 3.8 MW of heat to the steam. Fuel flow and energy content give engine power: 800 kg/h of fuel with a lower heating value near 43 MJ/kg carries 34,400 MJ per hour, which is 9.56 MW of fuel energy. In a polymer extruder, the throughput divided by the screw speed gives the mass per revolution: 120 kg/h is 2 kg/min, so at 60 rpm the screw moves 33.3 g per revolution. Reading these rates alongside the property of the material helps you see whether a number is plausible.
Conversions available on this page family
The site converts kg/h to kg/s, g/s, g/min, lb/s and lb/h. The factors are 1 kg/h = 0.000277778 kg/s = 0.277778 g/s = 16.6667 g/min = 0.000612395 lb/s = 2.20462 lb/h. In the other direction 1 kg/s is 3,600 kg/h, 1 g/s is 3.6 kg/h, 1 g/min is 0.06 kg/h and 1 lb/h is 0.45359237 kg/h. Each factor comes from the exact pound and the 3,600 s hour. A quick check: because 1 kg/h is 1,000 g per 3,600 s, divide by 3.6 to get g/s, which gives 0.2778. Dividing a kg/h value by 60 gives kg/min.
Worked examples from boilers and fuel feeds
A boiler producing 5,000 kg/h of steam delivers 5,000 / 3,600 = 1.3889 kg/s. An extruder running at 120 kg/h moves 33.33 g/s, since 120 / 3.6 = 33.33, and that is 2 kg every minute. A gas turbine burning 800 kg/h uses 0.2222 kg/s, and in pounds per hour that is 800 × 2.20462 = 1,763.7 lb/h. A small fuel feed of 18 g/min is 1.08 kg/h, from 18 × 0.06. An industrial oven that dries 45 kg of product per hour handles 1,080 kg in 24 hours. The same figures in a software tool that works in kg/s must be divided by 3,600 before use, and the answer converted back at the end. A 0.5 kg/s coolant flow, by contrast, is 1,800 kg/h.
Mass flow compared with volume flow
A kg/h reading and a volume flow in cubic meters per hour are connected by density. Water near room temperature has a density close to 998 kg/m³, so a flow of 1 m³/h is close to 998 kg/h, and treating it as 1,000 kg/h is a reasonable approximation for rough work. Gases are different, because density changes with pressure and temperature, so a standard cubic meter per hour does not convert to kg/h without the gas composition and the reference conditions. For air at 1.2 kg/m³, a duct moving 500 m³/h carries 600 kg/h. For this reason metering for fuels and steam is often done by mass, with Coriolis meters measuring the flow directly. A flow of 3 L/min of diesel with a density of 0.84 kg/L is 2.52 kg/min, or 151.2 kg/h.
Reading kg/h from a data sheet
A data sheet entry in kg/h can describe a nominal rate, a maximum rate or an average over a cycle, and the three are different. A feeder may advertise 500 kg/h at a particular material density, and its rate falls for lighter material. A boiler rated at 5,000 kg/h of steam delivers that figure at specified pressure and feedwater temperature. Check the conditions listed beside the number, and keep them with the value when you convert. The time base also matters when a plant runs part of a day. Annual totals multiply the hourly rate by running hours, not by 8,760, unless the equipment operates continuously. If a supplier quotes 2 t/h, the equivalent is 2,000 kg/h or 0.5556 kg/s, which is simple to check against the same figure printed on another sheet.
Spelling, symbols and shortcuts
The symbol is kg/h, also written kg·h⁻¹, and kg/hr is common in industry but not the SI form. The h is lowercase and stands for hour, and the SI symbol for second is s, so kg/s and kg/h should not be mixed in a table without a label. A slash in a compound unit should not be repeated, so kg/h/m² would be better written kg/(h·m²). Tonnes per hour are written t/h, and 1 t/h equals 1,000 kg/h. A common error is to read 10 kg/h as 10 kg per minute when scanning a table, so always check the denominator. Another trap is the plural: write 5 kg/h, with no s added to the unit.
What the conversion does not give
Converting a rate into another unit gives the same flow in new terms. It does not tell you a pump size, a pipe diameter, a heater duty or whether a plant can sustain that rate. Those need density, velocity, pressure, temperature and equipment ratings. A quantity of kilograms alone is a mass, not a flow, and it needs the hourly denominator before it can be compared with a rate in kg/s. Keep the time base, the product and the operating conditions with every value you record.
Precision and checking
- Retain source mass-flow precision.
- Keep repeating-factor rounding until display.
Reference numbers are displayed with up to twelve significant digits. That display does not add precision to a rounded measurement. Keep source and target quantities compatible, confirm symbol case and regional conventions, and round the final result to precision justified by the input. Factors involving π or repeating fractions use finite numerical precision.
Use a working converter
- Mass flow rate converter
- Kilograms per hour to Kilograms per second converter
- Kilograms per hour to Grams per second converter
- Kilograms per hour to Grams per minute converter
- Kilograms per hour to Pounds per second converter
- Kilograms per hour to Pounds per hour converter
Source and verification scope
The reference values and examples use the versioned unit definitions shared with the linked converters. Source dates identify the stated access or verification scope. A reverse calculation checks arithmetic and direction, but it does not independently verify a definition. Computandum is independent of the cited organizations, and the citations do not imply endorsement of this guide or a real application.