Measurement basis
The stored kg/s factor combines 0.001 kg per gram with 60 seconds per minute.
Definition conventions
Pounds use avoirdupois mass. A mass-flow unit conversion does not supply the density needed for a volume-flow relationship.
Conversion method
Multiply by 0.001 and divide by 60 for kg/s.
Reference equivalent of g/min
1 g/min = approximately 0.0000166666666667 kg/s.
Recorded scale factors: 0.000016666666666666666666666666666666666666666666666667 for g/min; 1 for kg/s.
Worked example
Known input: 10 g/min. Reference equivalent: 0.000166666666667 kg/s. The return conversion gives approximately 10 g/min.
The calculation changes both compound-unit components.
Common reference values
| Input (g/min) | Reference equivalent (kg/s) |
|---|---|
| 1 | 0.0000166666666667 |
| 5 | 0.0000833333333333 |
| 10 | 0.000166666666667 |
| 25 | 0.000416666666667 |
| 50 | 0.000833333333333 |
| 100 | 0.00166666666667 |
Compare one g/min with other units
| Target unit | Equivalent of 1 g/min | Definition guide |
|---|---|---|
| Kilograms per second (kg/s) | 0.0000166666666667 | Read definition |
| Kilograms per hour (kg/h) | 0.06 | Read definition |
| Grams per second (g/s) | 0.0166666666667 | Read definition |
| Pounds per second (lb/s) | 0.0000367437103641 | Read definition |
| Pounds per hour (lb/h) | 0.132277357311 | Read definition |
A slow mass flow
Grams per minute, g/min, measures how much mass passes a point each minute. It sits between milligrams per second and kilograms per hour. One g/min equals 1/60 g/s, which is 0.0166667 g/s, and 0.06 kg/h, 1.66667×10⁻⁵ kg/s and 0.132277 lb/h. Because the SI unit of mass flow is kilogram per second, g/min is a derived practical unit for small flows. It suits dosing, feeding and emission measurements where a rate of kilograms per second would produce very small numbers and a rate in kilograms per hour hides the minute scale of the process.
Feeders, dosers and pellet stoves
Industrial screw feeders and vibratory feeders are calibrated in g/min or kg/h, and dosing pumps for chemicals, additives or pharmaceuticals deliver flows in the range of a few g/min to hundreds of g/min. A pellet stove that burns 1.2 kg/h consumes 20 g/min of pellets. A plastics extruder running at 6 kg/h delivers 100 g/min. When a process requires a precise feed rate, the controller needs the flow in the unit its setpoint expects, so conversion between kg/h and g/min is a routine step. Multiply kg/h by 16.6667 to get g/min, or g/min by 0.06 to get kg/h.
Coffee and food preparation
Espresso extraction offers a small example in familiar terms. A 36 g espresso that takes 28 seconds has an average flow of 1.29 g/s, which is 77.1 g/min. A pour-over that delivers 300 g of water in 3 minutes runs at 100 g/min, and a slow drip at 60 g/min would take 5 minutes for the same water. Baristas track flow rate because it relates to contact time and extraction. For water, mass and volume are almost the same, so 100 g/min is about 100 mL/min, or 6 L/h. This equivalence fails for syrups, oils and other liquids.
3D printing and material extrusion
Extrusion flow in a 3D printer is usually given as volume per second, but the mass flow follows from density. A hotend that melts 15 mm³/s of PLA with a density of 1.24 g/cm³ is moving 18.6 mg/s, which equals 1.116 g/min. At that rate a 1 kg spool lasts about 896 minutes, or roughly 15 hours. A high-flow hotend at 30 mm³/s doubles this to 2.232 g/min. These figures help estimate print time and filament use, and they illustrate why the density must be known: the same volume flow of a denser filament carries more mass per minute.
Gas flow controllers
Mass flow controllers for gases are often specified in sccm, standard cubic centimeters per minute, and sometimes in g/min. The two are linked through the gas density at the reference conditions. For nitrogen at 0 °C and 1 atm, the density is about 1.25 g/L, so 1,000 sccm, which is 1 standard liter per minute, equals about 1.25 g/min. For helium the density is about 0.179 g/L, so the same 1,000 sccm is only 0.179 g/min. Standard conditions are defined differently by manufacturers, including 0 °C and 20 °C, so confirm the reference before converting a gas flow.
Emissions and test measurements
Emission test procedures report particulate and gaseous pollutants in g/min, g/s or g/km. A vehicle emitting 0.05 g/min of a pollutant while idling for 10 minutes releases 0.5 g. Laboratory fume cabinets and combustion experiments measure burn rate in g/min to compare fuels, and a candle that burns 0.1 g/min loses 6 g per hour. Converting between g/min and g/s is a division by 60, and conversion to kg/h multiplies by 0.06. Because many test standards specify the time base and unit, reporting in the specified unit avoids rejected results. A test that records 12.6 g over 7 minutes gives 1.8 g/min, which is 0.108 kg/h, and the same data written as 0.03 g/s lets a reviewer check it against a limit stated per second without redoing the arithmetic. State the averaging period beside the rate, because a rate averaged over a cold start differs from one measured at steady state.
Conversion ladder and examples
The converter uses these factors. One g/min equals 0.0166667 g/s, 0.06 kg/h, 0.0000166667 kg/s, 0.0000367437 lb/s and 0.132277 lb/h. Going the other way, 1 g/s is 60 g/min, 1 kg/h is 16.6667 g/min and 1 lb/h is 7.55987 g/min. A flow of 250 g/min is 4.1667 g/s, 15 kg/h and 33.07 lb/h. Because the factors are simple ratios, a quick check can catch a slip: g/min numbers are 60 times the g/s numbers and 16.7 times the kg/h numbers. Write the unit next to each value in every step of a calculation. Totals follow the same rule: a feeder that runs at 250 g/min for 45 minutes delivers 11,250 g, or 11.25 kg, and one that runs at 4 g/s for the same 45 minutes delivers 10.8 kg, so the two settings are not equivalent even though they look close.
Density needed for grams per minute
A mass flow cannot be converted to a volume flow without the density of the substance at the actual conditions. Water at about 20 °C has a density near 0.998 g/mL, so 60 g/min is about 60.1 mL/min. A syrup with a density of 1.3 g/mL gives 46.2 mL/min for the same 60 g/min. For gases, the density depends strongly on temperature and pressure, so a mass flow is the better quantity for control. This is why mass flow meters are chosen when the process needs a fixed amount of material per minute rather than a fixed volume at changing conditions. Coriolis meters measure mass flow directly from the twisting of a vibrating tube, and thermal meters infer it from heat carried away by the gas. Either type reads in g/min or kg/h without a density input, which suits small, steady flows.
Reading the unit correctly
Write g/min with a slash and without a plural s on the unit symbol. Avoid gpm, which usually means gallons per minute in the United States and is a volume flow of a very different size: 1 gal/min is 3.785 L/min. The letter g in g/min is the gram, not the gravitational acceleration. The converter changes a known flow between mass-flow units. It does not compute a flow from a pipe size or pressure, and it does not account for the density of a substance, which is needed before any volume flow can be given.
Precision and checking
- Retain source flow precision.
- Keep the repeating factor until final formatting.
Reference numbers are displayed with up to twelve significant digits. That display does not add precision to a rounded measurement. Keep source and target quantities compatible, confirm symbol case and regional conventions, and round the final result to precision justified by the input. Factors involving π or repeating fractions use finite numerical precision.
Use a working converter
- Mass flow rate converter
- Grams per minute to Kilograms per hour converter
- Grams per minute to Kilograms per second converter
- Grams per minute to Grams per second converter
- Grams per minute to Pounds per second converter
- Grams per minute to Pounds per hour converter
Source and verification scope
The reference values and examples use the versioned unit definitions shared with the linked converters. Source dates identify the stated access or verification scope. A reverse calculation checks arithmetic and direction, but it does not independently verify a definition. Computandum is independent of the cited organizations, and the citations do not imply endorsement of this guide or a real application.