Spec sheets that disagree on units
Mass flow tells you how much material passes a point each unit of time. Equipment documents choose different clocks and different masses. A humidifier or steam generator is rated in kg/h or lb/h, a laboratory dosing pump delivers grams per minute, a small extruder is set in g/s, and process-plant tables list kg/s. This converter brings those into one unit so you can compare a pump with a requirement, or move a US pound-per-hour rating into the metric figures that the rest of your spreadsheet uses. The default of 10 kg/s to kg/h returns 36,000, which shows how quickly the numbers grow when seconds become hours.
Time and mass, one at a time
It helps to treat the two parts of the unit separately. For the time part, there are 60 seconds in a minute and 3,600 in an hour. For the mass part, one kilogram is 1,000 grams, and one avoirdupois pound is exactly 0.45359237 kg, a value fixed in the 1959 international yard and pound agreement. For example, 2.5 g/s over 3,600 seconds is 9,000 g in an hour, which is 9 kg/h. Likewise 90 g/min times 60 minutes is 5,400 g/h, or 5.4 kg/h. The page applies the same logic, with the factors stored against kg/s.
Pound-per-hour ratings on boilers and dryers
US equipment, especially steam generators, dryers and burners, often states capacity in lb/h, and a metric project needs kg/h. A rating of 450 lb/h converts to about 204.117 kg/h, and a 1,200 lb/h unit is about 544.311 kg/h. For design documents it is usual to round to three significant digits, so 204 and 544 kg/h. Check whether the figure on the plate is steam output, fuel input or water evaporated, because the converter cannot tell the difference. It moves a number between units and leaves the interpretation to you. The same caution applies to rated and actual values. A burner or boiler plate states what the equipment can deliver at design conditions, and the figure on the display during operation can be lower. Convert both with the same factors so that the comparison between nameplate and measurement stays honest, and note which of the two you are quoting in any report.
Dosing and small flows in grams per minute
In a lab or a small production line, flows are small and a gram is the natural mass. A feeder set to 90 g/min delivers 5.4 kg/h, and a humidifier datasheet that lists 6 kg/h of output is 100 g/min. Going the other direction is useful when a controller asks for g/s: 36 kg/h is 600 g/min, or 10 g/s. For batch planning, multiply the hourly figure by the hours of the run to get the total mass, and compare it with the amount of raw material on hand. Do that arithmetic on the converted number, not on the original label. Another everyday case is a coffee roaster or a spice mill whose manual lists throughput in g/min while the supplier invoices in kilograms. A reading of 250 g/min is 15 kg/h, so a 60 kg order is four hours of running time. Writing the hourly figure beside the per-minute one in your notes avoids repeating the conversion each time you plan a batch.
Pounds per second against kilograms per second
Large flows in US documents, such as a fuel burn or a mass flow through a test cell, can appear in lb/s. A flow of 0.75 kg/s converts to about 1.65347 lb/s, and the same flow is about 5,952.48 lb/h. The ratio between lb/s and lb/h is 3,600, just as for kg/s and kg/h, so the conversion between pound units needs no metric step if both sides are in pounds. Mixed documents, with kg/s in one table and lb/h in another, are where the converter saves time and avoids a slip in the factor of 3,600.
Mass flow is not volume flow
A rate in kg/h says nothing about gallons, liters or cubic meters per time. To get volume flow, divide mass flow by density, and the density of the fluid at its operating temperature and pressure is what matters. For gases the volume per kilogram changes a great deal with pressure and temperature, which is why process engineers often prefer mass flow for gases and steam. This page performs no density step. If you need liters per minute, convert the mass rate here first and then divide by the density, or use a volume-flow tool.
Planning a batch from an hourly rate
Hourly rates become useful once you attach a run length. Suppose a feeder is set to 5.4 kg/h and a production run lasts 7.5 hours. The run consumes 5.4 × 7.5 = 40.5 kg, so a 50 kg bag covers it with 9.5 kg to spare. If the feeder were set in g/min instead, 5.4 kg/h is 90 g/min, and the same 7.5 hours is 450 minutes, which gives 40,500 g again. For a US-built machine rated at 12 lb/h, the page returns about 5.443 kg/h, and an 8 hour shift moves about 43.5 kg. Whichever clock you start with, convert first and then multiply, and finish by comparing the total with the material on hand and the size of the container it comes in.
Reading the result
The output is the same flow expressed against a different clock or mass. If the original number was a design requirement with two significant digits, the converted number does not become more accurate than that. For tables, round to the precision of the source. For an actual check of a pump or feeder, measure by collecting the material over a timed interval on a scale and then convert that observed rate. Collecting 450 g over 90 seconds, for example, is 5 g/s, which is 18 kg/h, and the timed method also reveals drift between the setting on the controller and what the machine delivers. That approach tests the equipment and the unit conversion together.
What the converter does not cover
The page converts units only. It does not size pipes, pumps, nozzles or valves, and it does not check ratings, limits or compliance with any code. Conversion factors for pounds assume avoirdupois pounds, not troy pounds, which differ in mass. If your source quotes a different convention, such as a flow in standard cubic feet per minute of a gas, convert with a tool that includes the gas reference conditions. Results are shown at full floating-point precision, so trim them to the significant digits of your input before they go into a specification or an order.