Hourly logs against per-second tables

Plant data systems log flows by the hour in kilograms, while many US textbooks, handbooks and manufacturer performance tables list mass flow in pounds per second. Students working problems from a US thermodynamics text face it when their lab data is metric. Engineers checking vendor data for a compressor, a steam turbine or a nozzle face it when the plant historian shows kg/h. Two conversions are packed into one: kilograms to pounds, and hours to seconds. This page applies both at once, so you do not have to chain factors and risk applying the wrong one. A frequent slip is to convert the mass and forget the time, which leaves a figure 3,600 times too large, or to convert the time and forget the mass, which is off by a factor of 2.2. The combined factor avoids both mistakes in one multiplication.

Building 0.000612 lb/s per kg/h

One kilogram is 2.20462262 lb, because the pound is defined as exactly 0.45359237 kg. One hour is 3,600 s. Therefore 1 kg/h = 2.20462262 ÷ 3,600 lb/s = 0.000612395 lb/s. The formula is lb/s = kg/h × 0.000612395. The reverse is kg/h = lb/s × 1,632.9325, found by multiplying 0.45359237 by 3,600. Remembering that 1 lb/s is about 1,633 kg/h gives a quick check on any large conversion. The pound here is a mass unit, often written lbm in thermodynamics texts to separate it from the pound-force. For rough work, 1 kg/h is about 0.0006 lb/s, and 1,000 kg/h is about 0.61 lb/s, which gives you a landmark for large flows. The factor is exact apart from the repeating decimals produced by dividing by 3,600.

What the default result says

Ten kg/h comes out at 0.00612395 lb/s. The number is small because an hourly flow spread over 3,600 seconds leaves little mass in each second, and a pound is about 0.45 kg, so the figure shrinks twice over. Results like this are common for modest flows and should not be rounded to zero, since 0.006 versus 0.0061 is a 2 percent difference. Carry at least four significant figures into a calculation, and format the final answer for the reader.

A compressor map and a plant log

A US vendor lists a flow of 1 lb/s on a performance curve, and your plant historian shows 1,633 kg/h. Entering 1,632.932532 kg/h returns 1.0000 lb/s, so the two agree. If the historian instead read 1,100 kg/h, the page returns 0.6736 lb/s, which sits well below the curve point and suggests the compressor is running at a lower load. Matching units first prevents a spurious mismatch from masking a real one. The page converts the unit only. Whether a flow lies inside the safe operating range of a machine comes from the manufacturer map, which also depends on pressure ratio and speed. Plotting the plant point on the vendor curve only works when both axes use the same mass unit, so convert the whole log column once and label it, instead of converting single points by hand.

Textbook problems and lab data

A problem from a US thermodynamics text gives steam flow as 2.2 lb/s and asks for the heat transfer. Your laboratory logger reads 3,600 kg/h, which is 2.20462 lb/s, almost identical. Students often miss that they must convert flow data before they plug into a table of enthalpy in BTU/lb. Converting 18,000 kg/h gives 11.0231 lb/s. Checking the order of magnitude helps: lb/s should be about 0.00061 times the kg/h number, so a result near 11 for 18,000 kg/h is right, while 110 or 1.1 would signal an error. In an exam setting, writing the conversion line with units on both sides, 18,000 kg/h × 2.20462 lb/kg ÷ 3,600 s/h, shows the reasoning and lets a grader see that the factors cancel to lb/s.

Fuel and air mass flow

Gas turbine and engine test data sheets often list fuel flow in lb/h and air flow in lb/s. A fuel flow logged at 500 kg/h is 0.3062 lb/s, which equals 1,102.31 lb/h, so the two US units differ by a factor of 3,600 and must not be confused. If a data sheet lists only the per-second figure and your tool displays per-hour, the conversion is this one in reverse. Always label the units explicitly on a plot axis, since lb/s and lb/h curves can look the same apart from the scale. When two data sets are compared on one chart, convert one to the unit of the other first, and note the factor in the figure caption so that a reader who wants to repeat the step can do so without searching for the source.

Pound mass versus pound force

The pound in lb/s here is mass. In US engineering practice, the pound-force and the pound-mass share a name and symbol root, and some texts use lbm and lbf to separate them. A flow in lbf/s is not a mass flow, and the converter does not handle it. Newton's second law in US units needs a gravitational constant, gc = 32.174 lbm·ft/(lbf·s²), to relate the two. For a mass flow like the one on this page, the constant does not appear and only the mass conversion matters. If a US source says only pounds per second without a subscript, assume mass flow when the context is a pump, compressor or turbine and check the text for lbf if a force is meant.

Presenting the answer

Choose notation that suits the audience. Scientific notation such as 6.12 × 10⁻³ lb/s reads cleanly for very small flows, and a table that mixes kg/h and lb/s should include a column header with the unit. Round to the precision of the source: a plant log with three significant figures supports a three-figure result. Keep the original value and unit in the document alongside the converted one, so a reviewer can retrace the step. Sheets with both units should carry the conversion factor in a labeled cell instead of hard-coding 0.000612395 in each formula, because a labeled constant is easy to audit and to correct once.

Compressor and turbine safe operation

The page converts a mass flow between units. It does not calculate installation limits, equipment ratings, protection, material response or compliance, and it does not say whether a compressor, turbine or pump operates safely at the flow you enter. Use manufacturer documentation for those decisions.