Rated in kilograms, checked in grams
Feeders, dosing screws, pellet dispensers and automatic fish feeders are rated by the hour, usually in kilograms. A person verifying one at the bench works differently: a cup under the outlet, a kitchen or lab scale reading in grams, and a timer that is easier to run for a minute than for an hour. The result is a flow in grams per minute that has to be compared with the kg/h rating on the label. This page does that comparison in one step. It is also useful in the opposite direction, when a process needs a target rate of, say, 75 g/min and you want the equivalent setting in the kg/h units the controller uses. Volumetric feeders deserve a fresh check whenever the material changes, because bulk density differs between lots and between regrind and virgin pellets, so a rate that held for one batch can drift for the next.
Where 16.6667 comes from
There are 1,000 grams in a kilogram and 60 minutes in an hour. A flow of 1 kg/h is therefore 1,000 g every 60 minutes, which is 1,000 ÷ 60 = 16.6667 g/min. The formula is g/min = kg/h × 16.6667, and the reverse is kg/h = g/min × 0.06. The factor repeats a 6 forever, so the page rounds the display. Memorizing that 6 kg/h is exactly 100 g/min gives a convenient anchor: every 6 kg/h adds 100 g/min, and every 60 g/min adds 3.6 kg/h. Both units are mass per time, so the conversion needs no density and works for pellets, powders, liquids and anything else you can weigh. By hand, divide the kg/h figure by 60 to get kg/min, then move the decimal point three places to the right to get g/min. For 12 kg/h that gives 0.2 kg/min and 200 g/min.
The default of 10 kg/h
The page opens with 10 kg/h and returns 166.667 g/min. As a plausibility check, 166.667 g/min for 60 minutes gives 10,000 g, which matches the 10 kg that the hourly figure describes. In terms of a ten-second test, the same flow delivers about 27.8 g. A bench scale reading in whole grams can therefore resolve that rate to within a few percent in ten seconds, and to better than one percent in a minute. The default is a simple starting point. Replace it with the rating from your own label, and keep the units of the scale in mind when you pick the test duration. If the scale only shows ounces, convert the reading to grams first, since this page assumes the mass is already in grams.
Catch and weigh on a pellet feeder
A gravimetric or volumetric feeder on a plastics extruder is often rated at a flow like 6 kg/h, and operators confirm it by diverting the output into a bucket for a fixed time. At 6 kg/h the target is 100 g/min, so a 30-second catch should weigh 50 g, and a 2-minute catch 200 g. If the bucket holds 44 g after 30 seconds, the feeder is running at 88 g/min, or 5.28 kg/h, about 12 percent low. Entering 6 kg/h confirms the target and entering the measured 88 g/min with the From and To menus swapped confirms the rate in kg/h. The page does the arithmetic and does not decide whether the feeder is within tolerance. Operators usually average three catches, discarding the first if the screw was starting from empty, because the first revolutions fill the flights and deliver less than the steady rate.
An automatic fish feeder
Aquaculture feeders discharge pellets by timer, and a farm that feeds 24 kg per day through one feeder running for 4 hours has a rate of 6 kg/h, which is 100 g/min. A hobby pond feeder is far smaller: 0.45 kg/h is 7.5 g/min, so a 2-minute run drops 15 g. Converting to g/min helps you set the run time on a controller that works in minutes. Feed rate is limited by what the fish eat, so the figure depends on species, water temperature and body size, and those come from the feeding table of the feed supplier, not from this page. If a table calls for 3 kg of feed per day split into two feedings, each feeding of 1.5 kg at 6 kg/h runs 15 minutes, a figure you can read off by converting 6 kg/h to 100 g/min and dividing 1,500 g by it.
Choosing the test duration
A longer test reduces the effect of scale resolution and start-up. If your scale reads to 1 g and you collect for one minute at 166.667 g/min, the reading error is under one percent. Collected for five seconds, the same resolution produces an error above seven percent. After you convert, divide the grams you expect by the time you plan to collect to find the target mass. A 24 kg/h rating corresponds to 400 g/min, so 90 seconds should collect about 600 g. Flow from vibratory and screw feeders pulses, so a few full cycles belong in the test.
Common slips in this conversion
The most frequent error is dividing by 100 instead of 60, which treats the hour as 100 minutes and makes the result 40 percent too small. Another is forgetting that kilograms become grams: 10 kg/h ÷ 60 is 0.1667 kg/min, which is 166.667 g/min after the factor of 1,000. A third is mixing up g/min with g/s, which differ by a factor of 60. Write the units next to each number as you go, and check that the answer is plausible: a rate in g/min should be about 16.7 times the kg/h figure.
Rounding and scale resolution
The converter returns many digits because the factor repeats, but your scale does not. If a feeder is rated 10 kg/h and your scale resolves 1 g, the result 166.667 g/min means little beyond 167 g/min. Report two or three significant figures and state the test time. When you compare against the label, allow for the feeder tolerance stated by the manufacturer, which is typically given as a percentage of the setpoint. A reading of 163 g/min against a 166.667 g/min target is within 2.2 percent, which many feeders meet in normal use.
Feeder and doser specifications
The converter expresses a known flow in another unit. It does not calculate installation limits, equipment ratings, protection, material response or compliance, and it does not tell you whether a feeder, pump or doser meets its specification or is safe for your product. For food, chemical or pharmaceutical dosing, follow the process documents for your plant and the applicable regulations.