Why equations ask for kilograms per second
Flow ratings on equipment are often given by the hour, because hourly figures are convenient for daily production and consumption. Engineering equations are written in coherent SI units, which means kilograms per second for mass flow. The heat balance Q = ṁ × cp × ΔT delivers watts when ṁ is in kg/s, cp is in J/(kg·K) and ΔT is in kelvin. If you put the hourly figure in directly, the answer is 3,600 times too large. This page does the division so the number entering the formula is correct, and it reports enough digits to carry through a longer calculation. The same rule applies to energy balances on a dryer, a cooling tower or a heat exchanger, where one hourly figure left in the wrong unit quietly ruins the kilowatt result without any error message to warn you.
Dividing by 3,600
An hour contains 3,600 seconds, so a flow of 1 kg/h equals 1/3,600 kg/s, or 0.000277778 kg/s. The formula is kg/s = kg/h ÷ 3,600. The reverse is kg/h = kg/s × 3,600, so 1 kg/s is 3,600 kg/h, which is 3.6 tonnes per hour. Since a kilogram appears on both sides, there is no mass conversion, and the factor involves no rounding other than the repeating decimal. The SI defines the second as the base unit of time, and the hour is a non-SI unit accepted for use with it, equal to 3,600 s by definition. In practice you can think of it as dividing by 3.6 and then by 1,000, so 36 kg/h is 10 g/s and therefore 0.01 kg/s, a useful chain when a calculator is not at hand.
What the default result means
The page starts at 10 kg/h and returns 0.00277778 kg/s. That is a small number, which is common for small flows in SI units. It equals 2.77778 g/s, so a convenient way to cross-check is to divide by 1,000 again. Many equipment flows land in the range of 0.001 to 10 kg/s, so values like this are natural and usually should not be rounded to zero. Keep at least four significant figures when the number enters a larger calculation, because rounding 0.00278 to 0.003 changes the result by 8 percent. Software with scientific notation fields takes 2.77778e-3 equally well, and that form avoids miscounting the leading zeros when you copy the number by hand.
Sizing heat for a water flow
A heater warms water flowing at 3,600 kg/h by 40 K. In SI form the flow is 1 kg/s, and with a specific heat of about 4,186 J/(kg·K) for water the heat required is 1 × 4,186 × 40 = 167,440 W, or about 167 kW. Entering 3,600 kg/h returns 1 kg/s, so the arithmetic is straightforward. Had you used 3,600 directly, the result would be 603 MW, a value so large it signals a unit error. Hot water, steam and chilled water calculations all follow the same pattern, with the specific heat or enthalpy difference of the fluid in place of the water value. For air warmed in a duct heater, a flow of 1,800 kg/h is 0.5 kg/s, and with a specific heat of about 1,005 J/(kg·K) a 20 K rise takes roughly 10 kW. Different fluids give very different heat for the same mass flow, so always use the specific heat of the actual fluid.
From a heat load to a flow in kg/h
For a hydronic coil that must deliver 50 kW with a 10 K temperature difference, the mass flow is 50,000 ÷ (4,186 × 10) = 1.1944 kg/s. Multiplying by 3,600 gives 4,300 kg/h, a figure that can be compared with the flow rating of a circulator. Entering 4,300 kg/h returns 1.1944 kg/s, which confirms the round trip. Because water has a density near 1,000 kg/m³, 4,300 kg/h is about 4.3 m³/h. Pump selection also depends on the system pressure drop, which this page does not calculate.
Steam and process flows
Boiler and steam system data sheets quote mass flow per hour, for example 1,800 kg/h of steam, which is 0.5 kg/s. A process line moving 7,200 kg/h of product moves 2 kg/s, and a metering pump feeding 90 kg/h of additive moves 0.025 kg/s. When these figures feed enthalpy balances or a simulation model, the SI form avoids a chain of 3,600 corrections spread through the formulas. Check the unit label in the model before you enter anything, as some software accepts hourly flows by default and others expect kg/s. A dosing pump of 90 kg/h feeding a mixer that is simulated at one-second steps adds 0.025 kg of additive each step, a number that is easy to see in SI form and hard to read off an hourly value.
Keeping mass and volume flow apart
Mass flow and volume flow are different things. Kilograms per second does not change with temperature or pressure, whereas liters per second does as density changes. A gas flow of 0.0278 kg/s of air at about 1.2 kg/m³ corresponds to about 0.023 m³/s, but the same mass of hot air takes more volume. The converter handles mass flow only. If your source gives liters or cubic meters per hour, convert to mass with the density at the operating state before entering the value, or use the appropriate volume flow converter instead. Liquid water is the one case where the numbers nearly coincide, since 1 kg is about 1 liter at room temperature, so 3,600 kg/h is about 3.6 m³/h. For oils, brines and gases, the density can differ greatly from one, and assuming it does is a common source of error in pump and fan sizing.
Significant figures and recording
Divide at the end of a calculation chain when possible, and keep the unit label with the number. A log that records 0.0028 kg/s next to 10 kg/h hides the fact that the first is a rounded version of 0.002778. Copy the full value into the spreadsheet cell and format it for display. When you share results, state the unit on every row, and use consistent notation such as kg/s or kg·s⁻¹ throughout a document. Where a report goes to several readers, give the hourly source value once in the text, then use kg/s in the equations that follow, so those who check the arithmetic can start from the same figure.
Pump, pipe and heater selection
The page converts a mass flow from one unit to another. It does not calculate installation limits, equipment ratings, protection, material response or compliance, and it does not select pumps, pipes or heaters. Use the manufacturer data and the design codes for those decisions.