Per second in the design, per hour in the report

Designers of conveyors, feeders and process lines compute flow in kilograms per second, because the equations of motion and heat are written in SI. Plant managers, purchasing departments and production reports talk about kilograms or tonnes per hour, because shifts and batches are timed by the hour. Someone has to carry the number across, and the factor of 3,600 is easy to misapply. This page multiplies by 3,600 and also lets you go back from an hourly rating to the SI value. The conversion is the same for gravel, flour, plastic pellets or water, since it concerns mass only. Volume-based ratings, such as cubic meters per hour for a screw conveyor, need the bulk density of the material before they can enter this page, and bulk density changes with moisture and packing.

Multiplying by 3,600

There are 60 seconds in a minute and 60 minutes in an hour, so 60 × 60 = 3,600 seconds per hour. A flow of 1 kg/s therefore moves 3,600 kg in an hour. The formula is kg/h = kg/s × 3,600, and the reverse is kg/s = kg/h ÷ 3,600. A handy equivalent: 1 kg/s is 3.6 tonnes per hour, so multiplying kg/s by 3.6 gives tonnes per hour directly. The factor is exact, so no rounding enters the conversion, and only the repeating decimal in the reverse direction needs rounding on display.

Reading the default

The default of 10 kg/s gives 36,000 kg/h, or 36 tonnes per hour. That is a realistic throughput for a medium conveyor in a quarry, a grain intake or a bulk handling line, and an extremely high flow for a food mixer or a pump feeding a small reactor. Compare the result with the capacity of the equipment you are considering. A rule of thumb for checking is that the number of kg/h should be about 3.6 thousand times the kg/s figure, so an answer with the wrong number of digits is easy to spot. A feeder rated 0.1 kg/s should land at 360 kg/h, and a rating of 0.01 kg/s at 36 kg/h. Small flows such as these are common for dosing screws and laboratory feeders, where an hourly figure is the way the supplier quotes capacity.

A belt conveyor in a bulk yard

The mass flow on a belt equals the load per meter of belt multiplied by the belt speed. A belt carrying 5 kg per meter at 1.5 m/s moves 7.5 kg/s. Entering 7.5 returns 27,000 kg/h, or 27 tonnes per hour. If the load is 8 kg/m at the same speed, the flow rises to 12 kg/s, which is 43,200 kg/h. Belt scales report the figure directly, and operators compare it with the plant target. The page handles the unit change, while the load per meter depends on the material, its bulk density and how the belt is loaded, which come from the weigh system and not from this conversion. Belt speed is read from a tachometer or from the drive data, and the load per meter from the load cells under a weigh idler. If either one drifts, the hourly total drifts with it, so plants check the belt scale against a test weight on a regular schedule and compare the totals with truck or rail weights.

A mill feed and a daily target

A grinding mill fed at 0.25 kg/s consumes 900 kg every hour, and a line that processes 2.5 kg/s handles 9,000 kg/h, or 9 tonnes. A plant that needs 30 tonnes per hour of feed has to deliver 30,000 ÷ 3,600 = 8.333 kg/s. Entering 8.3333 returns 29,999.9 kg/h, which rounds to the 30,000 target. Over a 20-hour operating day, 30 tonnes per hour gives 600 tonnes. Planning feed trucks and storage then comes down to arithmetic on the hourly figure, and the page makes the first step reliable. At 30 tonnes per hour, a truck that carries 24 tonnes is emptied through the hopper in 48 minutes, and the mill needs a new load about every 48 minutes, a number a dispatcher can use directly. Starting from the hourly feed rate and dividing the truck payload by it gives that interval without any further conversion.

Water and cooling flows

Cooling water systems list flows in kg/s or L/s in the design and in cubic meters or kilograms per hour on the pump nameplate. For water, 1 kg/s is close to 1 L/s, so 0.5 kg/s is 1,800 kg/h, about 1.8 m³/h. Entering 0.5 returns 1,800 kg/h. This is handy when comparing a heat exchanger design to a pump rated in m³/h. Because water density varies a little with temperature, the match is approximate, and for other liquids, such as brine or oil, the density must be applied before volume and mass can be swapped. A glycol mixture, for instance, is heavier than water, so 1 L/s of it carries more than 1 kg/s. Use the density from the fluid data sheet at the operating temperature.

Annual and monthly totals

Once you have kg/h, multiplying by operating hours gives production totals. A flow of 10 kg/s converts to 36,000 kg/h, so 8 hours gives 288,000 kg and a 300-day year with 16 operating hours a day gives 172,800,000 kg, which is 172,800 tonnes. Always apply the real operating hours, not 24 hours a day, because stops, changeovers and maintenance reduce the average. The page converts the rate. Production planning must still account for downtime and for variation of flow with the product being processed. Many plants track an availability factor, such as 85 percent, and multiply the nominal hourly figure by it, so that the 36,000 kg/h of a line becomes an expected 30,600 kg/h over a long period.

Avoiding unit slips

The two usual errors are using 60 instead of 3,600, which gives kg/min, and mixing tonnes with kilograms. A flow of 10 kg/s is 600 kg/min and 36,000 kg/h, so check which one the document needs. Also confirm the tonne: the metric tonne is 1,000 kg, the short ton is 907.185 kg and the long ton is 1,016.047 kg. For international documents use kg or tonnes and state it. Round to the accuracy of the original flow, which for a belt scale is often within one or two percent. Keep the unit in every column title of a report, and avoid writing t/h for a short ton in documents that also use tonnes, since the two differ by about 10 percent.

Conveyor and mill throughput

The page converts a mass flow from one unit to another. It does not calculate installation limits, equipment ratings, protection, material response or compliance, and it does not tell you whether a conveyor, mill or pump can handle the flow.