Permit figures and model inputs

Emission inventories, permit limits and stack test reports commonly state the release of a pollutant in kilograms per hour. Air dispersion models, on the other hand, commonly take the emission rate of each source in grams per second. Anyone moving numbers from one document to the other, whether a consultant building a model or a plant engineer checking a model report, converts kg/h to g/s over and over. A slip in the factor shifts every modeled concentration by the same proportion, so it pays to use a tool and then spot check one figure by hand. This page performs the conversion and shows enough digits to carry into a spreadsheet.

Dividing by 3.6

A kilogram is 1,000 g and an hour is 3,600 s, so g/s = kg/h × 1,000 ÷ 3,600 = kg/h × 0.277778. A more memorable way to say it is that you divide kg/h by 3.6. Ten kilograms per hour divided by 3.6 is 2.7778 g/s. The reverse multiplies by 3.6: 1 g/s equals 3.6 kg/h. The numbers are exact except for the repeating decimal in 0.2777..., which the page rounds for display. Because both units are mass per time, no density or temperature enters, and the conversion is the same for dust, sulfur dioxide, ammonia or any other substance reported by mass.

The default of 10 kg/h

The default of 10 kg/h converts to 2.77778 g/s, as shown by 10 ÷ 3.6. A mental check helps: 2.78 g/s over 3,600 seconds is 10,000 g, which is the 10 kg the hourly rate describes. The default is a convenient round number but a real source may be much smaller or larger. A small boiler stack might emit a few hundred grams per hour of a regulated pollutant, which is under 0.1 g/s, while a large industrial stack can release hundreds of kilograms per hour, which is tens of grams per second. Typing a figure with the wrong order of magnitude is a classic slip, so compare your result with the size of the source before you carry it into a model file.

A stack with a tested emission rate

Suppose a stack test reports 36 kg/h of particulate matter from a dryer. Dividing by 3.6 gives 10 g/s, which is the figure you would enter in a model for that source. A cleaner scenario of 0.9 kg/h gives 0.25 g/s, and a larger one at 72 kg/h gives 20 g/s. A source running at 5.4 kg/h gives 1.5 g/s. These round values come from numbers chosen to divide evenly by 3.6, which also makes them handy for checking spreadsheets. Real tests give values such as 7.43 kg/h, which converts to 2.064 g/s. Keep the same number of significant figures as the test report.

From one gram per second to a year of emissions

A rate of 1 g/s sustained for a full year releases 31,536 kg, or about 31.5 tonnes, found by multiplying 3,600 seconds per hour by 24 hours by 365 days. That number gives you a quick sense of scale when you compare an hourly rate with an annual limit in a permit. For instance, 10 kg/h running for 8,760 hours gives 87,600 kg, which equals 2.78 g/s times 31,536 kg per g/s. If the plant runs only 6,000 hours in a year, the total is 60,000 kg. The converter changes the rate unit. The annual total depends on operating hours and on any emission control that varies through the year. A plant that shuts down for maintenance for three weeks cuts the annual total by about six percent compared with continuous operation, which a plain hourly figure does not show.

Hourly rate versus averaging period

A kg/h figure is an average over the period of the test or the reporting hour. A source that emits intermittently can have a high instantaneous rate and a low hourly average, and the modeling guidance for the relevant program tells you which one to use. This page converts whatever number you enter and cannot know whether it is a peak, a mean or a permit limit. Write down in your notes what the kg/h value represents, such as a three-run test average or an allowed hourly maximum, so the g/s value carried into a model has a clear meaning. If a report gives the rate for a 30-minute stack run, a conversion to g/s describes that run and does not say what the source emits across a full day with different loads.

Area and volume sources

Some models want an emission rate per unit area, in g/(s·m²). To get there, convert the hourly rate for the whole source to g/s first, then divide by the area. A 2,000 m² storage yard that releases 7.2 kg/h gives 2 g/s, and dividing by 2,000 m² gives 0.001 g/(s·m²). That final divide is outside this page, but the first step is where unit errors typically creep in. Units for a source should be consistent with the model documentation, so look up the expected input for each source type before entering any number. Volume sources such as a building with several roof vents usually take the total rate for the whole source, and splitting that total over several vents is a modeling choice that comes before any unit conversion.

Reading the displayed digits

The page shows a long decimal because 1,000 ÷ 3,600 repeats. Most inventory data is known to two or three significant figures, so round the result to match. Reporting 2.7777777778 g/s for a 10 kg/h source suggests precision the input does not have. If you need the unrounded number for a script, copy the full value, and if you are writing a table, round at the end rather than at each step so that rounding errors do not accumulate through a chain of conversions. For a rough sanity check on any g/s result, multiply back: 2.064 g/s times 3.6 gives 7.43 kg/h, the value you started from. A second check is magnitude, since the g/s figure must always be a bit more than a quarter of the kg/h figure.

What this page does not do

The converter changes a mass flow from one unit to another. It does not calculate installation limits, equipment ratings, protection, material response or compliance, and it does not tell you whether an emission rate meets a permit or air quality standard. Those decisions depend on the regulations and permit conditions that apply to your site.