Picohenries in models and parasitics

Picohenries show up in simulation models and parasitic data: the equivalent series inductance of a capacitor, the inductance of a via, a bond wire or a short stub, and the small lead inductance listed in component models. A designer who also works with larger coils, in millihenries, may need to line up both on one scale to see which effect dominates. This page multiplies the millihenry value by 10^9 and shows the result in picohenries, the same inductance in a very small unit. The page leaves the quantity unchanged and only moves the decimal point nine places. People who need it are usually reading a capacitor model next to a coil datasheet, checking a student exercise that mixes scales, or writing a design note in which the parasitic and the designed inductance appear side by side and must be comparable at a glance.

How nine powers of ten come about

The prefix milli is 10^-3 and pico is 10^-12, so a millihenry contains 10^9 picohenries, a billion. The BIPM SI Brochure lists these prefixes, and the henry is one weber per ampere. The factor is defined and carries no uncertainty. Because the shift is nine places, the output of even a small input is a long number. Writing it in scientific notation, such as 1 × 10^10 pH for the default, is easier on the eye. Check a result by converting in two steps through nanohenries: multiply by one million, then by 1,000.

Ten millihenries in picohenries

The default of 10 mH gives 10,000,000,000 pH, ten billion picohenries. Smaller inputs give more readable numbers: 0.0000025 mH is 2,500 pH, and 0.0000005 mH is 500 pH, which is 0.5 nH. The default shows the scale gap well. A coil of 10 mH has twenty million times the inductance of a 500 pH parasitic. That gap is why a parasitic is invisible in a mains filter and decisive in a fast switching edge. Seeing both numbers in one unit makes the comparison obvious. Another useful anchor is that 1 mH equals 10^9 pH, so every extra millihenry adds a billion picohenries, and a coil of 0.001 mH, which is 1 µH, still holds one million picohenries. The pico unit only becomes comfortable once values drop below about a nanohenry.

Capacitor ESL and self-resonance

Every capacitor has some series inductance from its leads and body, often about a nanohenry for small ceramic parts, though the figure varies with package and mounting. That inductance and the capacitance form a series resonance at f = 1 / (2 × pi × the square root of L × C). With 1 nH, which is 1,000 pH, and 100 nF, the resonance falls near 15.9 MHz, and above that frequency the part behaves more like an inductor than a capacitor. The numbers are illustrative values for the calculation. Real parts have data in their datasheets or models, which should be used instead. A designer who wants the decoupling to work at higher frequencies usually picks a smaller case size or adds more capacitors in parallel, because parallel parasitic inductances combine like parallel resistances: two 1 nH parasitics in parallel give about 0.5 nH, or 500 pH, and four give 250 pH.

Converting picohenries back to millihenries

To convert in the other direction, select picohenries as the source and millihenries as the target. A value of 750 pH equals 0.00000075 mH, and 2,500 pH equals 0.0000025 mH. Divide by 10^9. The result has many leading zeros and is easy to copy wrongly, so the exponent form 7.5 × 10^-7 is safer to type into software. If your simulation tool takes henries, convert through nanohenries or henries instead: 750 pH is 0.75 nH and 7.5 × 10^-10 H.

Reading a model file

Netlists and component models may express inductance in plain henries with an exponent, such as 1.2e-9, or with a letter suffix like p for pico. In the common SPICE convention a lowercase m means milli and a capital M also means milli, not mega, and meg is used for mega. That quirk catches many users, so check the documentation of your tool before copying a value. When you move a number from a table in picohenries into a model, convert and verify the exponent, and run a quick simulation to see that the resonance lands where you expect. Some tools also accept a unit written after the number, such as 750pH, and others read only the exponent form, so a value that works in one program may be read as zero or as a different magnitude in the next. Test with a known value before trusting a long netlist.

Tracking digits at nine orders of magnitude

With a factor of a billion, a missing digit hides in a long string. Read the result in groups of three digits, and compare the digit count with expectation: an input of 1 digit in millihenries should produce about ten digits in picohenries. A wrong digit count means a unit was selected incorrectly. In notes, write the exponent next to the long number, so that a later reader can check it quickly. The page prints the result with the digits the engine produced, up to its display limit. If you need to check one value by hand, write the input as a power of ten times a small number, multiply the exponents, and count the zeros of the answer. For 2.5 × 10^-6 mH the product with 10^9 is 2.5 × 10^3, or 2,500 pH, which matches the example above.

Precision, uncertainty and rounding

The conversion adds zeros only, so the converted value has the same significant digits as the input. Parasitic inductance is rarely known to better than a few tens of percent, because it depends on layout, return path and measurement method. Quoting 500 pH, or even 0.5 nH, matches that uncertainty, while 500.000 pH would suggest too much. When you carry the value through a simulation, run a sensitivity check with plus and minus thirty percent to see whether the result changes enough to matter. If the answer holds across that range, the exact picohenry figure is not critical and the nearest round number is adequate. If it does not, a measurement of the actual board or a field-solver estimate is worth the time.

Parasitic inductance and layout extraction

This is a unit conversion. It does not extract parasitic inductance from a layout, predict self-resonance, verify a model or check ratings. Real values depend on frequency, geometry and measurement conditions. Use the page for consistent numbers and rely on datasheets, field solvers and measurements for the values themselves.