MEASUREMENT & METHODS

Nanohenries (nH): inductance unit guide

nH is the nano-prefixed inductance entry.

Measurement basis

One nH corresponds to 10^-9 H.

Definition conventions

The supported prefixes are SI decimal powers, with conversions confined to inductance.

Conversion method

Multiply nH by 10^-9 for the reference, retaining the small result until display.

Reference equivalent of nH

1 nH = approximately 1e-9 H.

Recorded scale factors: 0.000000001 for nH; 1 for H.

Worked example

Known input: 10 nH. Reference equivalent: 1e-8 H. The return conversion gives approximately 10 nH.

The example expresses the same inductance on the henry scale.

Common reference values

Input (nH)Reference equivalent (H)
11e-9
55e-9
101e-8
252.5e-8
505e-8
1001e-7

Compare one nH with other units

Target unitEquivalent of 1 nHDefinition guide
Henries (H)1e-9Read definition
Millihenries (mH)0.000001Read definition
Microhenries (µH)0.001Read definition
Picohenries (pH)1000Read definition

One billionth of a henry on a circuit board

A nanohenry (nH) is 10^-9 henry, the SI coherent unit of inductance, scaled by the prefix nano. The henry itself is a derived unit equal to one weber per ampere, or one volt-second per ampere, which in base units is kg·m²·s⁻²·A⁻². The name honors Joseph Henry, the American physicist who studied self-induction in the 1830s, and the International Electrical Congress held in Chicago in 1893 is the usual source given for the unit name. The BIPM SI Brochure lists the henry among the derived units with special names and allows any SI prefix. The nanohenry is the unit in which stray and intentional inductance appears in high-frequency design, because the values involved are far too small to read comfortably in henries.

Where values in nH come from

Typical nanohenry values sit in the range from a fraction of one nH to a few hundred nH. A common rule of thumb puts a straight printed-circuit trace or a bond wire at about 1 nH per millimeter of length, with the real figure depending on width, height above the return plane and geometry. A via adds a fraction of a nanohenry to a couple of nanohenries. Chip inductors for radio-frequency matching networks are sold in values such as 2.2 nH, 10 nH and 100 nH, often in 0402 or 0603 packages. Component codes sometimes use the letter N as the decimal marker, so 4N7 means 4.7 nH. Power inductors for switching converters are usually microhenries, so a datasheet in nH points to a radio-frequency or high-speed digital context.

Reactance and resonance at nanohenry scale

A small inductance matters only when the frequency is high. Reactance is X = 2πfL, so 10 nH at 100 MHz has a reactance of about 6.283 Ω, and the same coil at 1 GHz reaches about 62.83 Ω. Pairing 10 nH with 1 pF gives a resonant frequency f = 1 / (2π√(LC)) of about 1.592 GHz, which is the order of magnitude of the tuned circuits in Wi-Fi, GPS and Bluetooth front ends. A tuned circuit built from nanohenry coils is physically small, which is why the unit dominates in that field. Every inductor also has a self-resonant frequency set by its own parasitic capacitance, and above that frequency it behaves like a capacitor, so the nominal nH value is only meaningful below it.

Factors to the units next door

The prefix ladder is simple. One nH equals 0.001 µH, 0.000001 mH and 1,000 pH, and 1 H equals 1,000,000,000 nH. A 4.7 µH inductor is therefore 4,700 nH, and 330 pH is 0.33 nH. The site converter pages for Henries to Nanohenries, Nanohenries to Microhenries, Nanohenries to Picohenries and Microhenries to Nanohenries apply exactly these factors. The older centimeter-gram-second electromagnetic system defined the abhenry as 10^-9 H, so one abhenry equals one nanohenry. In that system inductance carried the dimension of length, and the unit was sometimes simply called the centimeter. You may meet it in older physics texts and in the NIST SP 811 table of non-SI units, and it needs no conversion beyond renaming.

Reading nH on schematics and data sheets

The symbol is nH with a lowercase n and an uppercase H, because H honors a person. Writing NH or nh does not follow the SI Brochure and invites errors in a parts list. A tolerance may be stated in nH for small values, such as ±0.1 nH on a 2.2 nH part, rather than as a percentage, because percentage tolerances become unwieldy at the low end. Data sheets also publish a test frequency for the inductance, often 100 MHz or higher, and a quality factor Q at a stated frequency. The same inductor can be listed with different inductance values at different test frequencies, so compare parts at the same condition. A value copied without its test frequency can differ from the figure a designer needs.

Mixing up nH with similar labels

Nanohenries are easy to confuse with units that share letters. The unit nH is inductance, while nF is capacitance and nS is conductance. A trace labeled 3 nH and a part labeled 3 nF are separate component types even though both are tiny values. The prefix is also a trap for factors of 1,000: a 0.1 µH inductor is 100 nH, and reading that as 0.1 nH puts the value off by a thousand. Inductance also needs to be separated from inductive reactance, which is measured in ohms and changes with frequency. An inductor does not have an inherent ohm rating, and a quoted reactance in Ω only applies at the frequency stated beside it.

Measuring inductance this small

Instruments that read microhenries comfortably become unreliable at a few nanohenries, because test leads and fixtures contribute inductance of the same order. Vector network analyzers and impedance analyzers with calibrated fixtures are the usual tools, and measurements are made at the frequency where the part will work. Even a short pair of probe leads adds several nanohenries, so a bench LCR meter reading of 12 nH from a 10 nH part can come entirely from fixture effects. When a result must be trusted, measure the empty fixture, subtract it, and keep the stated resolution of the instrument in view. A converted value in henries carries no more precision than the original nanohenry reading.

What a component lead costs at gigahertz

The 1 nH per millimeter rule of thumb has practical consequences. A 5 mm length of lead or trace adds about 5 nH in series, and at 1 GHz that is a reactance of 2π × 10^9 × 5 × 10^-9, about 31.4 Ω, which can wreck the match of a 50 Ω line. The same lead at 10 MHz adds only about 0.31 Ω and goes unnoticed. This frequency scaling is why decoupling capacitors are mounted with short, wide connections and why radio layouts keep ground vias close to the part. The rule is an estimate for planning, and field solvers or measurements give the actual figure for a specific board.

Choosing between nH and the next unit up

The scale printed in a document should keep the number readable without leading zeros. Values from 1 nH up to a few hundred nH read naturally in nanohenries, 0.1 µH and above read naturally in microhenries, and values below 1 nH are often given in picohenries, such as 500 pH for a package lead. Henries are reserved for large inductors such as power-line reactors, relay coils or transformer windings. When you convert, scale the number and keep the significant figures: 12.5 nH becomes 0.0125 µH and 1.25 × 10^-8 H, and none of those forms adds accuracy to the original reading. Use the form that matches the data sheet your reader will check against.

Precision and checking

  • Keep source inductance resolution.
  • Retain nH with a small reading.

Reference numbers are displayed with up to twelve significant digits. That display does not add precision to a rounded measurement. Keep source and target quantities compatible, confirm symbol case and regional conventions, and round the final result to precision justified by the input. Factors involving π or repeating fractions use finite numerical precision.

Use a working converter

Source and verification scope

The reference values and examples use the versioned unit definitions shared with the linked converters. Source dates identify the stated access or verification scope. A reverse calculation checks arithmetic and direction, but it does not independently verify a definition. Computandum is independent of the cited organizations, and the citations do not imply endorsement of this guide or a real application.

Sources

Read the calculation and sourcing methodology →