MEASUREMENT & METHODS

Inductance: units and measurement guide

Inductance describes magnetic flux linkage relative to current under a defined model.

Measurement basis

A unit value by itself does not assess whether a circuit is suitable for an installation.

Definition conventions

The supported prefixes are SI decimal powers, with conversions confined to inductance.

Conversion method

Use the stored henry-factor ratio to rescale a known inductance.

Choose the conversion direction

Confirm the source H symbol and prefix, then select a target inductance unit.

The henry and what it relates

Inductance links the voltage across a coil to how fast the current through it changes. The SI unit is the henry, symbol H, defined so that a current changing at 1 ampere per second induces 1 volt: 1 H = 1 V·s/A, which is the same as 1 Wb/A. The unit honors Joseph Henry, the American scientist who studied self-induction in the 1830s, around the time Michael Faraday worked on mutual induction in Britain. Inductance depends on the geometry of the conductor and the material around it, not on the current. A circuit element designed to provide a chosen inductance is called an inductor, and the quantity also appears as a parasitic property of every wire loop and printed circuit trace.

Sizes from nanohenries to henries

Practical inductors span many orders of magnitude. A short trace on a circuit board contributes roughly 10 nH per centimeter. Radio-frequency coils run from nanohenries to tens of microhenries. Power supply inductors range from about 1 µH to 1 mH, and mains-frequency chokes and transformer windings reach tens of millihenries up to several henries. Prefix steps follow powers of 1000: 1 H = 1000 mH = 10^6 µH = 10^9 nH = 10^12 pH. So 4.7 µH equals 4700 nH or 0.0047 mH. The jump between neighboring prefixes is large enough that a misplaced decimal usually produces a design that cannot work at all, which makes the notation worth checking twice.

Reactance at a given frequency

An inductor resists alternating current by its reactance, X = 2πfL. A 10 µH inductor at 1 MHz has a reactance of about 62.8 Ω. The same part at 100 kHz gives 6.28 Ω, and at 10 MHz it gives 628 Ω. That frequency dependence is why a small inductance matters at radio frequencies yet is almost invisible at mains frequency. At 50 Hz, a 10 µH inductor has a reactance of 0.00314 Ω. Reading the henry value is therefore only half of a component choice, because the frequency of use decides whether the part blocks, passes or merely tolerates the signal.

Energy and time constants

An inductor stores energy in its magnetic field, equal to one half of L times the current squared. A 2 mH inductor carrying 5 A stores 0.5 × 0.002 × 25 = 0.025 J, which is 25 mJ. In an RL circuit the current rises with a time constant L/R, so 2 mH with a 4 Ω resistance has a time constant of 0.5 ms. These relations are why the henry unit connects naturally to joules, seconds and ohms: 1 H equals 1 Ω·s, which is a quick check when an equation produces an unfamiliar unit.

Related units and conversions

Within the SI, conversions are powers of ten. Three older systems also appear in the literature. In the centimeter-gram-second electromagnetic system the unit is the abhenry, equal to 1 nH, so 1000 abhenries make 1 µH. The electrostatic unit, the stathenry, is about 8.988 × 10^11 H, a number almost never needed outside historical texts. Some datasheets for ferrite beads and chokes quote impedance in ohms at a frequency instead of inductance. That value cannot be converted into henries without knowing the frequency and whether the part behaves inductively there, and a unit converter cannot supply either.

Inductance from a coil geometry

For a long solenoid, inductance is approximately μ0 N² A / l, where N is the number of turns, A the cross-sectional area, l the length and μ0 the permeability of free space, about 1.2566 × 10^-6 H/m. A coil of 500 turns, 2 cm² area and 5 cm length gives roughly 1.26 × 10^-6 × 250,000 × 0.0002 / 0.05, which is about 1.26 mH. Inserting a ferromagnetic core multiplies the result by the relative permeability, which can reach hundreds to thousands depending on the material. The guide treats the henry and its prefixes only. Winding formulas are approximations that assume a uniform field and ignore end effects.

Mutual inductance and coupling

Two coils sharing a magnetic path have a mutual inductance M, also measured in henries. Transformers rely on it: the voltage induced in the secondary winding is M times the rate of change of primary current. The coupling coefficient k, between 0 and 1, relates M to the self-inductances through M = k√(L1·L2). Two 10 mH coils with k = 0.9 have a mutual inductance of 9 mH. Wireless charging coils are designed around the same idea. Because both self and mutual terms use the same unit, a datasheet listing leakage inductance in µH and magnetizing inductance in mH needs a prefix conversion before the two can be compared directly.

Reading 4R7 and 4u7 markings

Component markings sometimes use the letter R or the letter u as a decimal marker or as the micro prefix, so 4R7 means 4.7 and 4u7 means 4.7 µ. The symbol µ is the Greek letter mu, while an m on its own stands for milli, and mixing the two gives a factor of 1000. Uppercase H is the henry, whereas lowercase h is the Planck constant symbol and unrelated. Inductance is not the same as flux, which is measured in webers, or magnetic field strength. A reading in webers, such as flux linkage, becomes an inductance only after dividing by the current, so no prefix change converts a flux value into henries. Series and parallel combinations follow resistor-like rules when the coils do not couple: two inductors of 3 mH and 6 mH in series give 9 mH, and in parallel give 2 mH, found from (3 × 6) / (3 + 6). Keeping every value in one unit before combining them avoids the common slip of adding 3 µH to 6 mH as if both were the same prefix.

Measuring a coil and checking it with resonance

An LCR meter reports inductance at a chosen test frequency, commonly 1 kHz or 100 kHz, and a coil can read differently at each because core losses and winding capacitance change with frequency. Datasheet tolerances range from about 5 percent for RF parts to 20 percent for many power inductors. A second check uses resonance: an inductor of L with a capacitor C resonates at f = 1 / (2π√(LC)). For 10 µH and 100 pF, the product is 10^-15, its square root is 3.162 × 10^-8, and the frequency is about 5.03 MHz. If a measured resonance sits far from that value, either the capacitance or the inductance is not what the label says. Stray capacitance of the winding itself shifts the result, which is why self-resonant frequency is listed on datasheets as the upper limit for using the part as an inductor.

Precision and checking

  • Keep the original inductance precision.
  • Preserve the source model and conditions separately from the unit scale.

Reference numbers are displayed with up to twelve significant digits. That display does not add precision to a rounded measurement. Keep source and target quantities compatible, confirm symbol case and regional conventions, and round the final result to precision justified by the input. Factors involving π or repeating fractions use finite numerical precision.

Choose a unit definition

Use a working converter

Source and verification scope

The reference values and examples use the versioned unit definitions shared with the linked converters. Source dates identify the stated access or verification scope. A reverse calculation checks arithmetic and direction, but it does not independently verify a definition. Computandum is independent of the cited organizations, and the citations do not imply endorsement of this guide or a real application.

Sources

Read the calculation and sourcing methodology →