What a microhenry value looks like in henries

Most inductors that appear on circuit boards are labeled in microhenries or millihenries, because the henry is a large unit for everyday components. A 10 µH inductor is one you might find in a small switching regulator or in an RF filter. In henries it is 0.00001 H, which is a number with four leading zeros after the decimal point and easy to miscopy. This page turns the µH value into henries by dividing by 1,000,000, so you can paste the result into a formula or a simulation that expects base SI units. The default input of 10 µH gives 0.00001 H, or 1 × 10^-5 H. The converter also offers millihenries, nanohenries and picohenries, so it covers the neighboring prefixes if your source uses a different one. It does not look up parts or check that a value is a standard one.

The unit and the prefix definition

The henry is the SI unit of inductance, named after the American scientist Joseph Henry. One henry is the inductance in which a current changing at one ampere per second induces an electromotive force of one volt. In SI base units that is kg·m²·s^-2·A^-2, and it equals one weber per ampere. The micro prefix, symbol µ, is defined as 10^-6 in the BIPM SI Brochure and in NIST SP 811, which means a microhenry is a millionth of a henry. The formula on the page is H = µH × 0.000001. Because the prefix is an exact power of ten, the conversion has no rounding error of its own. If you see a result like 0.000009999999999999999 in a floating-point tool, that is a display artifact of binary arithmetic, and the intended value is 0.00001 H.

The default example, step by step

The default is 10 µH to henries. Dividing 10 by 1,000,000 gives 0.00001. Equivalently, you can move the decimal point six places to the left: 10.0 becomes 0.000010, and trimming trailing zeros gives 0.00001. In scientific notation that is 1 × 10^-5 H. A second example is 4.7 µH, a value from the standard E6 series, which converts to 0.0000047 H, or 4.7 × 10^-6 H. A third is 220 µH, common in older power supplies and filter chokes, which is 0.00022 H or 2.2 × 10^-4 H. In each case the significant digits stay the same and only the exponent changes. When you enter the result in software that accepts engineering notation, such as 4.7u in many circuit simulators, you may not need to convert at all, but a spreadsheet or a hand calculation usually does.

Why the henry is rarely used directly

Practical inductors are far smaller than one henry. A small surface-mount chip inductor can be a few nanohenries, a power inductor in a laptop charger can be a few microhenries, and the large iron-core chokes in mains-frequency power supplies reach into the millihenry and henry range. That spread is why the prefixes matter. A value typed in the wrong prefix changes a calculated resonant frequency or ripple current by orders of magnitude, so it is worth converting once and writing the base-unit value into your notes. The comparison with capacitance is useful. Capacitors are commonly picofarads to microfarads and are also written with prefixes, and resonance formulas such as f = 1/(2π√(LC)) need both in base units. Mixing a microhenry value in a formula that expects henries is a typical source of a result off by a factor of a million or a thousand.

A resonance example

An LC circuit resonates at f = 1/(2π√(LC)), where L is in henries and C is in farads. As an illustration, take 4.7 µH, which is 0.0000047 H, and a 220 pF capacitor, which is 0.00000000022 F. The product LC is about 1.034 × 10^-15. Its square root is about 3.216 × 10^-8. Multiplying by 2π gives about 2.021 × 10^-7, and the reciprocal is about 4.95 × 10^6 Hz, so the resonant frequency is near 4.95 MHz. If you forgot to convert and used 4.7 for the inductance, the result would be off by a factor of about 1,000 in frequency, since the frequency scales with the inverse square root of L, and 4.7 versus 0.0000047 differs by a factor of a million. These values are illustrative and describe an ideal pair without parasitic effects.

Energy stored in an inductor

The energy stored in an inductor carrying current I is W = ½LI², with L in henries and I in amperes. For the default 10 µH carrying 3 A, the energy is 0.5 × 0.00001 × 9, which is 0.000045 J, or 45 µJ. That is a small amount, but in a switching converter the energy is delivered hundreds of thousands of times per second, so the power throughput is meaningful. At 500 kHz switching with that full energy delivered each cycle, the power would be 45 µJ × 500,000, or 22.5 W. This is an idealized estimate. Real designs use the inductor's saturation current rating and the duty cycle, and the full peak energy is not necessarily transferred every cycle. The calculation only shows why a base-unit value in henries is needed: with L in microhenries the formula gives microjoules only if you carry the prefix correctly.

Tolerance, saturation and real parts

A nominal inductance on a data sheet is not a fixed property of the part in every condition. Common power inductors have a tolerance of ±20 percent, and precision RF parts can be ±2 percent or better. The inductance also changes with DC bias. As the current approaches the saturation rating, the core loses permeability and the inductance drops, and manufacturers typically define a saturation current at which inductance has fallen by 20 or 30 percent. Temperature and frequency shift it as well. Converting 10 µH to 0.00001 H gives the nominal value only. A circuit that needs a resonant frequency within a tight window has to account for the tolerance and for the capacitance of the other components. The converter offers the unit change and does not know which of these effects apply to your part.

Reverse conversion and neighboring prefixes

To go from henries to microhenries, select henries in the From list and microhenries in the To list, and the page multiplies by 1,000,000. Entering 0.0015 H returns 1,500 µH, which is the same as 1.5 mH. The ladder of prefixes is regular: 1 H is 1,000 mH, 1,000,000 µH, 1,000,000,000 nH and 1,000,000,000,000 pH. A quick conversion between neighbors moves the decimal point three places, so 10 µH is 0.01 mH and 10,000 nH. If a bill of materials lists inductors in different prefixes, convert them all to one before comparing or summing.

Common mistakes with µH

The symbol µ is the Greek letter mu, and in plain text it is often replaced by u, so 10 uH means 10 µH. A frequent slip is to read m for milli and µ for micro as equivalent, which produces an error of a factor of 1,000. Another is a data sheet or schematic that writes the value without a unit, such as 100 on a chip marked with a code, where the meaning depends on the convention in use. A third error comes from copying results from a program that switches to exponent notation, such as 1E-05, and dropping the exponent. On this page the output is labeled in henries, so check that you have the sign of the exponent right: a small number means a small inductance, and a result larger than the input would signal that the conversion went the wrong direction.

What the page does not cover

The page takes a number on trust. A 10 µH entry returns 0.00001 H even if the part on your bench measures 8 µH under DC bias, and the page cannot work out inductance from turns, core material or coil geometry. Mutual inductance, tolerance and saturation all live outside it. For code-governed electrical work, use the manufacturer's data and the standards for your installation. The BIPM SI Brochure and NIST SP 811 define the henry and the micro prefix.

Reading inductor markings and series values

Inductor values come in preferred number series, much like resistors. The E6 series has 1.0, 1.5, 2.2, 3.3, 4.7 and 6.8 per decade, and the E12 series fills in between with 1.2, 1.8, 2.7, 3.9, 5.6 and 8.2. A catalog listing 1.0, 2.2, 4.7, 10, 22, 47, 100, 220 and 470 µH is using E6 values across three decades. Converting a whole column to henries moves each entry by six decimal places, so 2.2 µH is 0.0000022 H and 470 µH is 0.00047 H. Some small parts carry a three-digit code, where the third digit is a multiplier and the value is read in microhenries: 101 means 10 followed by one zero, which is 100 µH, and 4R7 means 4.7 µH. Conventions differ between manufacturers, so check the data sheet before converting a coded value.

Series and parallel combinations

Inductors that are far enough apart to ignore mutual coupling combine like resistors. In series the inductances add, so 10 µH and 4.7 µH give 14.7 µH, or 0.0000147 H. In parallel the reciprocals add. Two 10 µH inductors in parallel give 5 µH, or 0.000005 H, and 10 µH in parallel with 10 µH and 10 µH gives 3.33 µH. If the coils share a magnetic path or sit close together, mutual inductance changes these results, and the total depends on the coupling and the winding direction. When you combine values from different sources, convert everything to the same prefix first, because adding 10 µH to 0.0047 mH without converting gives a wrong sum. The easiest route is to bring all values to henries or all to microhenries before applying any formula.