Reading inductor labels and codes
Small molded inductors carry three-digit codes in microhenries: the first two digits are the value and the third is the number of zeros, so 102 means 1,000 microhenries, which is 1 mH. Smaller parts use an R for the decimal point, such as 4R7 for 4.7 microhenries. Datasheets for the same parts may list the value in millihenries, and bench meters show whichever unit fits the display. The page links the units: 1 H is 1,000 mH, 1,000,000 microhenries, or 1,000,000,000 nanohenries. Convert before you compare two parts, because a 2.2 mH choke and a 2,200 microhenry choke are the same component written two ways.
What the default of 10 H shows
Ten henries is a very large inductance for a single part. It is typical of old tube-amplifier filter chokes and of big iron-core components, and it equals 10,000 millihenries. For modern boards, values run from nanohenries through microhenries to a few millihenries. The default is useful as a check on the direction of the conversion, since henries to millihenries should always make the number a thousand times larger. A result smaller than the input means the menus are reversed. Work with the unit shown on the part, and convert only when a calculation or comparison needs a common basis. A bill of materials is a good place to apply that habit: list every inductor in one unit, such as microhenries, so a quick scan reveals duplicates, typing slips and values that differ by a factor of 1,000. Flag any line whose value looks out of range for its position in the circuit before ordering parts.
Speaker crossover coils
Passive crossovers in loudspeakers use coils with values between about 0.1 mH and 10 mH. A 2.2 H coil would be absurd, while 2.2 mH is common for a woofer filter, which is 0.0022 H. Builders who follow a design given in henries, or use a calculator that outputs henries, need the millihenry value to buy a part. A calculated 0.47 H is clearly a mistake, and 470 mH tells you a decimal slipped. Wire gauge and resistance matter too, since a coil with high direct current resistance will cost output, so check the data sheet beyond the inductance. Typical crossover designs for a two-way speaker put a coil of about 0.3 to 1 mH in series with the woofer, which is 0.0003 to 0.001 H. Air-core coils avoid saturation at high volume, while iron-core versions pack more inductance into less space at the price of distortion and a heavier component.
Power supplies and buck converters
Switching regulators use inductors of 1 to 100 microhenries, with common values near 4.7, 10, 22 and 47 microhenries. A 22 microhenry coil is 0.022 mH. Designers sometimes calculate in henries in a script and then need the datasheet millihenry value, or the reverse. Choosing a coil also depends on saturation current, ripple current and the resistance of the winding, none of which appear in a unit conversion. Converting is simply the way to ensure that the 330 microhenry part in your parts list, which is 0.33 mH, matches the 0.33 mH shown in the tool that generated the design.
Combining coils in series and parallel
Coils far apart on a board, with no shared magnetic field, add like resistors. In series, 4.7 mH plus 10 mH gives 14.7 mH, which is 0.0147 H. In parallel, two equal coils give half of one. Mixed units are a common source of errors: if one value is in henries and the other in millihenries, convert first, then add. A series chain of 2.2 mH, 1,500 microhenries and 0.5 mH totals 4.2 mH. Coils that sit close together couple magnetically and change the result, so this simple arithmetic holds only for well-separated parts.
Wound coils and air-core choices
The inductance of a hobby coil depends on its geometry. For a single-layer air-core coil, a common approximation multiplies the square of the turns by the square of the coil diameter and divides by a term built from the coil length and diameter. Online calculators using inches often report the answer in microhenries, while a speaker design sheet wants millihenries. A coil that comes out at 850 microhenries is 0.85 mH, and one that comes out at 0.0012 H is 1.2 mH. Always confirm the unit shown in the result field, since one calculator may show henries while the next shows microhenries, and a slip of three decimal places is invisible until the circuit misbehaves.
Resonant frequency checks
A tuned circuit has a resonant frequency of 1 divided by 2 pi times the square root of inductance times capacitance. With 1 mH, which is 0.001 H, and 10 microfarads, the frequency comes to about 1,591.55 Hz. If you accidentally entered 1 H, the frequency would fall to about 50 Hz, a sign that a unit slipped. Converting between henries and millihenries before running the formula is the cheapest protection. The page makes no claim about quality factor, losses or tolerance, which can move a real circuit away from the textbook value by several percent.
Using an LCR meter
A bench LCR meter reads inductance at a chosen test frequency, often 100 Hz, 1 kHz or 100 kHz, and the displayed value can change with frequency, especially for iron-core parts. Meters show results in H, mH or microhenries, depending on range. A reading of 0.47 H corresponds to 470 mH, and a reading of 1,500 nanohenries equals 0.0015 mH. Record both the number and its unit, and the test frequency, when you note down a part. When you compare readings from two different instruments, converting them to one unit shows whether the difference is real or only a matter of prefixes.
Scope and limits of the page
The page expresses the same known inductance in another unit. It does not calculate installation limits, equipment ratings, protection, material response or compliance, and it does not tell you whether a coil is suitable for a given current or voltage. The henry is defined in the SI as one weber per ampere, which equals one volt second per ampere. Millihenries and the other submultiples follow decimal prefixes, so the conversions are exact. If a result looks surprising, check the menus first, because a wrong prefix changes the answer by a factor of 1,000 or more.