MEASUREMENT & METHODS

Picohenries (pH): inductance unit guide

pH is a pico-prefixed inductance symbol here.

Measurement basis

Its reference factor is 10^-12 H.

Definition conventions

The supported prefixes are SI decimal powers, with conversions confined to inductance.

Conversion method

Multiply pH by 10^-12 for henries.

Reference equivalent of pH

1 pH = approximately 1e-12 H.

Recorded scale factors: 1e-12 for pH; 1 for H.

Worked example

Known input: 10 pH. Reference equivalent: 1e-11 H. The return conversion gives approximately 10 pH.

The example uses inductance rather than another meaning of pH.

Common reference values

Input (pH)Reference equivalent (H)
11e-12
55e-12
101e-11
252.5e-11
505e-11
1001e-10

Compare one pH with other units

Target unitEquivalent of 1 pHDefinition guide
Henries (H)1e-12Read definition
Millihenries (mH)1e-9Read definition
Microhenries (µH)0.000001Read definition
Nanohenries (nH)0.001Read definition

Inductance at the scale of a wire segment

The picohenry, symbol pH, is 10⁻¹² henry. The henry is the SI unit of inductance, equal to one weber per ampere or one volt second per ampere, and it is named after the American scientist Joseph Henry. One henry is large for most electronics, and the units seen on real parts are microhenries and nanohenries. Picohenries describe the inductance of very short conductors, such as a via through a circuit board, the lead of a surface-mount capacitor or a bond wire inside a chip package. Because every conductor has some inductance, the value matters in fast switching and radio-frequency work, where a few hundred picohenries produce a measurable voltage when the current changes quickly.

Estimating a bond wire

For a straight round wire, a standard approximation is L = 2 × 10⁻⁷ × ℓ × (ln(2ℓ/r) − 0.75) henries, with length ℓ and radius r in meters. A gold bond wire 1 mm long and 25 µm in diameter has r = 12.5 µm, so 2ℓ/r = 160, the logarithm is 5.075, and L is about 8.65 × 10⁻¹⁰ H, which is 0.865 nH or 865 pH. A common rule of thumb for wires and traces is about 1 nH per millimeter, equal to 1,000 pH/mm. The formula is an approximation that ignores nearby ground planes, which lower the loop inductance. Real package data sheets give the specified values, and they should replace a rule of thumb.

Capacitor mounting inductance

Every capacitor has a small series inductance, the equivalent series inductance or ESL. Together with the capacitance it forms a series resonance, and above that frequency the part behaves as an inductor. A 100 nF ceramic capacitor with 500 pH of ESL resonates at 1/(2π√(LC)), which is about 22.5 MHz. Low-inductance designs with reversed terminals or wide geometry can reach ESL values of 100 to 300 pH. At 1 GHz, 500 pH has a reactance of 2πfL, or about 3.14 Ω, and that is why decoupling for fast processors uses many small capacitors with short vias. The mounting pads and vias often add more inductance than the capacitor itself.

Superconducting circuits and SQUIDs

Superconducting quantum interference devices and related circuits work with inductances in the picohenry to nanohenry range. A SQUID loop in a sensitive magnetometer may have an inductance of the order of 100 pH, and the product of that inductance and a critical current sets how the device responds to magnetic flux. A loop of 100 pH with a flux quantum of 2.07 × 10⁻¹⁵ Wb would need a circulating current of about 10.3 µA to carry half a flux quantum, since the current times the inductance equals the flux. Superconducting resonators and qubit circuits are designed with similar values, and the design software reports them in pH or nH. At these dimensions geometry controls everything. Kinetic inductance from the motion of Cooper pairs adds to the magnetic inductance and depends on temperature and film thickness. Because the inductances are so small, numerical field solvers are used rather than hand formulas.

Converters from nH and µH to pH

The unit ladder is decimal. Nanohenries to Picohenries multiplies by 1,000, Microhenries to Picohenries by 10⁶, Millihenries to Picohenries by 10⁹ and Henries to Picohenries by 10¹². Going down, Picohenries to Nanohenries multiplies by 0.001, Picohenries to Microhenries by 10⁻⁶ and Picohenries to Millihenries by 10⁻⁹. A 2.2 nH RF inductor is therefore 2,200 pH, and a 0.87 nH bond wire is 870 pH. Moving the decimal point is all the work, so the usual error is a shift of three places. Using engineering notation, with exponents in multiples of three, keeps the result readable, and it matches the prefix steps of the SI.

Reactance and voltage spikes

An inductor resists changes in current, and the voltage across it is L times the rate of change of current. Switching 1 A in 1 ns through 1 nH of loop inductance produces 1 V, which is 1,000 pH giving 1 V per ampere per nanosecond. A power converter that switches 10 A in 5 ns across a 500 pH loop sees a spike of 1 V, from V = L di/dt, and that can exceed a gate margin on a fast transistor. For that reason layout engineers shrink the current loop area, because loop area controls inductance. A picohenry-level reduction in layout can matter more than a larger component change, and it costs nothing in parts. Two conductors carrying current in opposite directions lie close together to cancel their fields, and that is the reason return paths on a ground plane are routed directly beneath their signal traces.

The pH symbol and chemical pH

The symbol pH for picohenry is the same as the one chemists use for the acidity scale, where the lowercase p stands for the negative logarithm of hydrogen ion activity. The two have nothing in common except the letters, and context separates them. In electronics the unit is pH after a number with a space, and capacitors and inductors in a parts list make the meaning clear. Soil or water sensors, by contrast, report pH as a dimensionless number on a scale that runs from about 0 to 14, with no unit attached. A table that mixes pH values from a soil sensor with picohenry values from a layout tool needs labels. The SI rule for a prefix symbol is lowercase for pico and capital H for henry, because the unit is named after a person. A capital PH is neither a valid prefix nor a unit.

Accuracy, simulation and measurement

Inductances in the picohenry range are hard to measure directly. Impedance analyzers and vector network analyzers infer them from reactance at high frequency, and fixture inductance has to be removed by calibration. A small error in the lead length or ground connection changes the result by tens of picohenries. Field solvers give a value for a given geometry, but the answer depends on the mesh and on the frequency chosen. When two sources disagree by a few hundred picohenries, check what loop is being described, such as the capacitor alone or the capacitor plus its vias. Quote the frequency and test fixture with the figure, and keep the digits that the method supports. A series inductor labeled 0.5 nH in a datasheet is usually a nominal figure with a tolerance of plus or minus 0.1 nH or more, which equals 100 pH of uncertainty on a 500 pH part.

Precision and checking

  • Retain measured inductance resolution.
  • Keep the inductance context.

Reference numbers are displayed with up to twelve significant digits. That display does not add precision to a rounded measurement. Keep source and target quantities compatible, confirm symbol case and regional conventions, and round the final result to precision justified by the input. Factors involving π or repeating fractions use finite numerical precision.

Use a working converter

Source and verification scope

The reference values and examples use the versioned unit definitions shared with the linked converters. Source dates identify the stated access or verification scope. A reverse calculation checks arithmetic and direction, but it does not independently verify a definition. Computandum is independent of the cited organizations, and the citations do not imply endorsement of this guide or a real application.

Sources

Read the calculation and sourcing methodology →