Tiny inductances in a base-unit formula
Inductance values at the picohenry level come from layout extraction, from the data sheet of a high-frequency capacitor or from a field-solver run on a via or a short wire. The formulas that use them, such as the resonant frequency of an LC pair or the reactance of a lead, expect henries. This page multiplies the picohenry number by 10^-12, so that 250 pH becomes 2.5e-10 H and the default of 10 pH becomes 1e-11 H. Engineers who paste values into a spreadsheet, students who check a homework answer and analysts who write scripts around simulator output can use the page to confirm the exponent before running the calculation that depends on it. A mistake at this step carries through every later result, so a single check on one value is cheap insurance.
Pico against the base unit
Pico means 10^-12, so a picohenry is a trillionth of a henry and one henry holds 10^12 pH. The formula is H = pH × 10^-12. The BIPM SI Brochure and NIST SP 811 define the prefix, and the ratio is exact. The henry itself is the SI unit of inductance, equal to one weber per ampere or one volt-second per ampere. By hand, shift the decimal point twelve places to the left: 500 pH is 5 × 10^-10 H, and 2,000 pH is 2 × 10^-9 H. Spreadsheets and programming languages read the e form directly, so a value like 2.5e-10 can be typed into a cell without counting zeros.
Reading 1e-11 and its neighbors
The default input of 10 pH gives 1e-11 H. An input of 250 pH gives 2.5e-10 H, 500 pH gives 5e-10 H, and 1,000 pH, which is 1 nH, gives 1e-9 H. The reverse direction produces long numbers: 1 H is 1,000,000,000,000 pH, and 0.000001 H is 1,000,000 pH. A fast sanity check is to subtract the exponents: the answer in henries should be twelve orders of magnitude below the number of picohenries. If a script returns 2.5e-7 for 250 pH, the factor 10^-9 was applied by mistake, which is the factor for nanohenries.
Resonance with a small capacitor
The resonant frequency of an inductor and a capacitor is f = 1 / (2π × √(L × C)), with L in henries and C in farads. Take an illustrative parasitic inductance of 250 pH, which is 2.5e-10 H, and a capacitance of 10 pF, which is 1e-11 F. The product is 2.5e-21, its square root is 5e-11, and the frequency is about 3.18 GHz. Enter the picohenry value as 250 instead of 2.5e-10 and the result would be wrong by a factor of 10^6 in frequency, which is why the conversion should come first. The page covers the unit step, and the formula is yours to apply to your own numbers.
Reactance of a short lead
A short conductor behaves as an inductor at high frequency, with reactance X = 2π × f × L. A lead of 250 pH, which is 2.5e-10 H, has a reactance of about 1.57 Ω at 1 GHz and about 0.016 Ω at 10 MHz. At low frequency the lead is invisible, and at gigahertz frequencies it starts to matter in a ground return or a supply decoupling path. The figures show why high-speed designs keep connections short and place decoupling capacitors close to the pins. A longer path of 1 nH, which is 1e-9 H, would have four times the reactance of the 250 pH lead. The conversion lets you compute these numbers in base units.
Where picohenry values come from
Capacitor manufacturers publish equivalent series inductance, usually in nanohenries, and a small ceramic part in a standard package may sit between a few hundred picohenries and about a nanohenry. A via through a board can add a few hundred picohenries, depending on its length and the return path. A bond wire in a chip package adds around a nanohenry for a millimeter or so, as a rule of thumb. Field solvers and extraction tools report these values with a stated precision, and the numbers often come out in picohenries when a structure is very small. The page works on any number you type, and the origin of the value determines how far to trust it. A figure from a datasheet at a stated test frequency is a different kind of number from one produced by a quick layout estimate, and the report should say which it is.
Going from henries back to picohenries
To check an answer that came out in henries, choose henries as the From unit and picohenries as the To unit. A result of 3e-10 H is 300 pH, 1.5e-9 H is 1,500 pH, and 5e-12 H is 5 pH. This direction is useful when a simulator reports a result in base units and you want to compare it with a data sheet limit written in picohenries. It is also a way to catch a unit error in a netlist: if a component meant to be 300 pH shows up in the log as 3e-7 H, the suffix was entered as nano instead of pico. Converting the log value back to picohenries makes the difference plain.
Suffixes in simulators and scripts
Circuit simulators use short suffixes: p for 10^-12, n for 10^-9, u for 10^-6, and m for 10^-3. Inductor values in a netlist might read 250p or 0.25n for the same 250 pH. A trap is that m means milli and not mega, which is written meg, so 1m is a millihenry, a billion times larger than 1p. Scripts that read values from text should be tested on a known case, such as 250 pH becoming 2.5e-10. This page supplies the reference value for that test, and a mismatch tells you whether the parsing code or the data is at fault. Add a second test with a value that has a decimal, such as 0.5 nH, to catch parsers that drop the fraction.
A picohenry figure needs its test frequency attached
The page changes how an inductance is written and nothing more. It does not extract parasitics from a layout, compute mutual coupling, model skin effect or predict how a structure behaves at a frequency. Real inductance values depend on geometry, return path, nearby conductors and frequency, and a measurement at picohenry level needs a suitable fixture and calibration. For design decisions, use a field solver or a measurement, and take the numbers from the manufacturer for components. Use this page to keep the exponents right while you carry those numbers into the formulas. Write the final answer with its unit and the frequency or test condition, since an inductance without that context is hard to reuse.