Coils measured in millihenries, strays in picohenries

Loudspeaker crossover coils, common-mode chokes and relay windings are rated in millihenries, while the stray inductance of a wire or a capacitor lead is counted in picohenries. When someone asks whether a parasitic can disturb a coil circuit, the answer comes from the size of the ratio, and the ratio needs one unit. This page multiplies the picohenry value by 10^-9, so 10 pH returns 1e-8 mH. The comparison shows right away that a stray of a few hundred picohenries is a vanishing part of a 1.5 mH coil. Hobbyists building crossovers and engineers who check a design can use the result as a quick confirmation. A coil value taken from a catalog and a stray value taken from a simulation seldom share a unit, which is the reason to convert before comparing.

Passing through the microhenry as a cross-check

Milli is 10^-3 and pico is 10^-12, so a millihenry equals 10^9 picohenries, one billion. The formula is mH = pH × 10^-9. The prefixes appear in the BIPM SI Brochure and in NIST SP 811, and the ratio is exact. Move the decimal point nine places to the left: 470 pH becomes 4.7 × 10^-7 mH, and 2,200,000,000 pH becomes 2.2 mH. A two-step check passes through the microhenry, since one millihenry is 1,000 µH and one microhenry is 1,000,000 pH. The page uses scientific notation for small results, because a value like 0.00000001 is hard to read without counting zeros.

Reading the display for 10 pH

With the default of 10 pH the page shows 9.999999999999999e-9 mH, which is 1 × 10^-8 mH. The trailing nines are an artifact of binary arithmetic and should be rounded. Other inputs: 470 pH gives 4.7e-7 mH, and 1,000,000 pH gives 0.001 mH. Reversing the direction, 1 mH is 1,000,000,000 pH, 1.5 mH is 1,500,000,000 pH, and 2.2 mH is 2,200,000,000 pH. These are long numbers, and nobody writes a crossover coil in picohenries. The conversion helps when you document a stray term and a main component in one table, where each value must carry the same unit and the same notation.

Crossover coils and reactance

An inductor in a speaker crossover has a reactance X = 2π × f × L, so a 1 mH coil has about 6.28 Ω at 1 kHz. A first-order low-pass filter for an 8 Ω woofer built with 1.5 mH has a corner frequency of R / (2π × L) = 8 / (2π × 0.0015), about 849 Hz. A stray of 500 pH adds 5e-7 mH, which at 1 kHz contributes 3.1e-6 Ω of reactance and cannot affect the sound. The numbers make the point clearly: parasitics at picohenry level matter at gigahertz, and coils at millihenry level matter in the audio range. The converter helps you see which is which. A designer who works across both ranges, for instance on a class D amplifier output filter, meets coils of several microhenries at one end and board parasitics of hundreds of picohenries at the other.

Chokes and relay coils

A common-mode choke in a mains filter may have an inductance in the range of a few millihenries per winding, chosen to suppress high-frequency noise on a cable without affecting the 50 or 60 Hz supply. A relay coil or a solenoid has tens of millihenries or more, which sets how quickly its current builds up when voltage is applied. In both cases a stray of a few picohenries has no practical effect, but the same parts have parasitic capacitance between windings that limits their high-frequency behavior. Data sheets give the inductance at a stated frequency and current. Convert the nominal values, then check the measurement conditions before you compare two parts.

Measuring at the two extremes

An LCR meter measures a millihenry coil easily, but a value of a few picohenries is far below what bench meters resolve. To measure parasitics, engineers use a network analyzer with a calibrated fixture, or they extract the value from a simulation and then check a resonance on the actual board. Because the two measurement methods are so different, the numbers should come from different tools and be combined only after conversion. The page does not measure anything. It gives you the same figure in the unit that suits your report, and you should note the method and the frequency alongside it. A reading taken at 1 kHz may differ from one taken at 100 kHz, especially for coils with iron cores, so the test frequency belongs in the record.

Reversing the direction

Choose millihenries as the From unit and picohenries as the To unit to expand a coil value. A 0.1 mH coil is 100,000,000 pH, a 10 mH choke is 10,000,000,000 pH, and a 0.33 mH coil is 330,000,000 pH. If you are writing a script to compare stray terms with main inductances, those values provide test cases for the parsing code. A ratio of one billion between a coil and a parasitic term is a sign that the parasitic can be ignored at the frequency of interest, though the opposite holds in the radio range, where a few nanohenries in a lead can detune a circuit that uses a few nanohenries in total.

Case and symbol errors

In SI, a lowercase m is milli and a capital M is mega, so mH and MH are very different. A value written in a table as 2.2 MH would be 2.2 megahenries, which does not exist as a component. Software that forces capital letters can create this error without notice, so a column of values should be checked after an import. Likewise a lowercase h is not the symbol for henry, which is a capital H. Keep the unit exactly as the SI Brochure prints it, and spell it out once in a report for readers who are not familiar with the symbols.

Rated inductance at zero bias drops once current flows

The page converts a prefix. It does not calculate the inductance of a coil from its turns and core, the current at which a core saturates, the self-resonant frequency or the losses. Those depend on the winding, the material, the temperature and the frequency. For a design that matters, use the manufacturer data and a measurement under the conditions of use. A coil whose rated inductance is given at zero DC bias may fall well short of that value when current flows, so check the curve. The converter keeps the exponent correct while you transfer a number between documents or calculations.