MEASUREMENT & METHODS

Thermal resistance: units and measurement guide

Thermal resistance relates temperature difference to heat flow for a specified object or model.

Measurement basis

Total thermal resistance and area-normalized thermal insulance are separate quantities.

Definition conventions

These units express temperature difference per power. Building R-value uses area-normalized thermal insulance.

Conversion method

Use the stored temperature-interval and power factors without applying an absolute-temperature offset.

Choose the conversion direction

Confirm that the source is total resistance before selecting a K/W or compatible target.

Temperature difference per unit of heat flow

Thermal resistance describes how large a temperature difference is needed to push a given amount of heat through an object or a path. It is written R = ΔT / P, where ΔT is the temperature difference across the path and P is the heat flow in watts. The SI unit is the kelvin per watt, K/W. A part rated at 2 K/W will sit 2 kelvins warmer on its hot side than on its cold side for every watt flowing through it. The idea mirrors electrical resistance: temperature difference plays the role of voltage, heat flow plays the role of current, and the same series and parallel rules apply. Because it belongs to a specific part, with its own shape and size, thermal resistance is a property of an object, not of a material.

Why a degree Celsius per watt equals a kelvin per watt

The unit is built from a temperature interval, not a temperature reading. A difference of 1 kelvin is the same size as a difference of 1 degree Celsius, so °C/W and K/W are the same number, and datasheets use both. The Celsius offset of 273.15 never enters, because it cancels when you subtract two temperatures. The Fahrenheit degree is smaller, so an interval of 1 °F equals 5/9 K. One kelvin per watt is therefore 1.8 °F/W, and one °F/W is 0.5556 K/W. A heat sink rated at 0.5 K/W is about 0.9 °F/W. Do not add or subtract 32 in this conversion, because that offset belongs to absolute temperature readings and has no role in a rise or drop.

K/W and K/kW for different scales of equipment

Electronics catalogs quote small values per watt, while large heat exchangers and building envelope components are easier to read per kilowatt. One K/W equals 1,000 K/kW, so a boiler wall of 0.004 K/W is 4 K/kW. The prefix changes only the size of the power in the denominator, which means the number moves in the opposite direction to what many readers expect: dividing by a larger power unit makes the figure larger, not smaller. Check the denominator on any datasheet before comparing two values, because 0.5 K/W and 500 K/kW describe the same part. A liquid cold plate listed at 20 K/kW that carries 500 W shows a rise of 10 K, the same as a part marked 0.02 K/W.

Resistances in series and in parallel

The useful feature of thermal resistance is that paths combine. A chip dissipating heat through the die, a thermal pad, a heat sink and then into air passes through four resistances in series, and the totals simply add. Suppose junction-to-case is 1.2 K/W, the pad is 0.3 K/W, the heat sink is 2.5 K/W and the heat-sink fins to air are included in that figure. The sum is 4.0 K/W. At 10 W of dissipation the junction runs 40 K above the ambient air. When heat can leave by two routes at once, such as a board and a heat spreader, the reciprocals add, so two 8 K/W paths give 4 K/W together. For unequal paths, 6 K/W in parallel with 12 K/W gives (6 × 12) / (6 + 12) = 4 K/W, always lower than the smaller path.

Reading datasheet symbols such as θJA and RθJC

Semiconductor datasheets use symbols that follow the JEDEC convention. RθJC or θJC is junction to case, RθJB is junction to board and RθJA is junction to ambient. A TO-220 power transistor might list around 60 K/W junction to ambient in still air, but around 1 to 2 K/W junction to case. The first value depends heavily on the test board, copper area and airflow, so it describes the test setup more than your design. The second is more portable because it covers only the package interior. If you attach a heat sink, you build the chain yourself from junction to case, interface material, sink and air, using the case-based values rather than the ambient one.

Thermal resistance of a slab from geometry

For one-dimensional conduction through a flat layer, R = L / (k × A), with L the thickness in meters, k the thermal conductivity in W/(m·K) and A the area in square meters. A copper spreader 5 mm thick with a contact area of 1 cm² and k near 400 W/(m·K) gives 0.005 / (400 × 0.0001), about 0.125 K/W. The same geometry in aluminum, with k near 235, rises to about 0.21 K/W. Doubling thickness doubles the resistance, while doubling area halves it. This is the reason heat spreaders are wide and thin. Conductivity values vary with alloy and temperature, so treat any single figure quoted here as an illustrative value and use your supplier data for a real design.

How it differs from the R-value on insulation

Building R-values and thermal resistance share a name and a physical idea but not a unit. Insulation is rated per unit of area: the US R-value is in ft²·°F·h/Btu, and the SI equivalent, often called RSI, is in m²·K/W. One RSI equals about 5.678 US R-value. To get K/W from an area-normalized figure, divide by the real surface area: a wall section of 10 m² with RSI 3.5 has a thermal resistance of 0.35 K/W. A K/W number cannot be turned into an R-value unless you know the area it applies to, and a bare R-value cannot be converted into K/W without the same piece of information.

Where the number comes from and what it leaves out

Manufacturers measure thermal resistance by dissipating a known power, recording temperatures with sensors or the diode voltage of the device, and dividing the difference by the power. Standards bodies such as JEDEC publish the board layouts and airflow conditions for those tests. A K/W value assumes steady state. During a short power pulse the part heats according to its thermal capacitance, which is described by a transient thermal impedance curve instead. Resistance also changes slightly with temperature and with how heat spreads sideways, so the figure on a datasheet is a planning number. The junction limit that the result is compared with, often 125 °C to 150 °C for silicon devices, comes from the maximum ratings table of the same datasheet.

A worked temperature-rise estimate

Take a regulator dissipating 5 W, mounted on a heat sink rated at 6 K/W with a pad of 0.4 K/W between them, and an internal junction-to-case value of 3 K/W. The series total is 9.4 K/W, so the junction is expected to sit 47 K above the surrounding air. In a 25 °C enclosure that predicts a junction near 72 °C. The same chain written in the unit used by a US vendor is 16.92 °F/W, and in K/kW it is 9,400. All three figures describe one resistance, and the rise stays 47 K whichever way you write it.

Precision and checking

  • Keep object/model context and source precision.
  • A temperature difference uses interval scaling rather than zero-point offsets.

Reference numbers are displayed with up to twelve significant digits. That display does not add precision to a rounded measurement. Keep source and target quantities compatible, confirm symbol case and regional conventions, and round the final result to precision justified by the input. Factors involving π or repeating fractions use finite numerical precision.

Choose a unit definition

Use a working converter

Source and verification scope

The reference values and examples use the versioned unit definitions shared with the linked converters. Source dates identify the stated access or verification scope. A reverse calculation checks arithmetic and direction, but it does not independently verify a definition. Computandum is independent of the cited organizations, and the citations do not imply endorsement of this guide or a real application.

Sources

Read the calculation and sourcing methodology →