Datasheets for heat sinks, chips and power modules

Heat sink catalogs list thermal resistance in °C/W, semiconductor datasheets give junction-to-case and junction-to-ambient values in K/W or °C/W, and power modules often list a junction-to-case figure in K/kW because the numbers are small. A designer who reads 0.3 °C/W for a CPU cooler and 12 K/kW for a power module has to restate one of them before adding. This page converts among K/W, K/kW, °C/W and °F/W. Because the denominator is power and the numerator is a temperature interval, a kelvin and a Celsius degree are the same size, so K/W and °C/W give the same number, while the Fahrenheit degree is 1.8 times smaller than a kelvin. The page lists all four units in both menus, which lets you move straight from a catalog value to the unit your calculation sheet uses.

The factors in plain terms

The stored base is K/W. A K/kW value is 1,000 times the K/W value, because a kilowatt is 1,000 W and the same temperature rise per kilowatt is a larger figure per unit of the smaller denominator. Celsius per watt equals kelvins per watt. Fahrenheit per watt is 1.8 times the K/W number: 0.3 K/W is 0.54 °F/W. The page shows the default as K/kW = K/W × 1000. Intervals do not use the 32-degree offset that temperature scales do, which is why no addition appears in the formula. NIST SP 811 and the SI Brochure document the kelvin and the prefixes behind these factors.

Ten kelvins per watt and a real cooler

The default of 10 K/W gives 10,000 K/kW. A value of 10 K/W would be a small bare heat sink or a chip in still air, where a 2 W part rises 20 K. A good tower cooler on a desktop processor is much lower, around 0.1 to 0.3 °C/W depending on airflow. To see what that means, take an illustrative 65 W load. At 0.3 °C/W the cooler-to-air rise is 19.5 K, and at 0.1 °C/W it is 6.5 K. Enter 0.3 with K/W as the source and K/kW as the target and the answer is 300 K/kW, which is the style used for large industrial exchangers and power electronics. Writing the unit symbol in full, K/kW, beside the number avoids any doubt about whether the kilowatt belongs to the denominator.

Adding resistances in series

Heat crossing several layers faces their resistances in series, and they add. As an illustration, a transistor with a junction-to-case value of 0.5 K/W, a thermal pad of 0.2 K/W and a heat sink of 0.35 K/W gives 1.05 K/W in total. At 40 W the rise from junction to ambient is 42 K. If the pad is quoted in K/kW as 200 K/kW, it must become 0.2 K/W before the sum. Mixing units inside a sum is the typical source of a result that is off by a factor of 1,000, so converting every term first is worth the extra step. Always match the power basis, since a figure per kilowatt is not a per-watt figure. If one term comes from a datasheet in K/kW and another from a catalog in °C/W, convert both to K/W, add, and only then multiply by the power. The same habit works for a long chain, such as die attach, substrate, baseplate, grease and heat sink, where five or six numbers from different documents are combined.

Power module ratings in K/kW

Datasheets for IGBT and power MOSFET modules commonly give Rth(j-c) in K/kW, with values around 10 to 20 for mid-size modules. A module with 12 K/kW is 0.012 K/W. If it dissipates 1,200 W, the junction sits 14.4 K above the case, a figure obtained from 0.012 × 1,200. Those numbers are illustrative. The datasheet value depends on the chip count, the baseplate and the conditions of measurement, and the datasheet usually states whether it applies per switch or per module. The page converts the unit and leaves such definitions to the document you took the number from. Where a datasheet gives a transient thermal impedance curve for short pulses, that curve is a separate quantity and is not what this page converts.

Fahrenheit per watt in US catalogs

Some US catalogs list resistance in °F/W, usually for older enclosures or thermoelectric parts. Because the Fahrenheit interval is smaller, the number grows: 0.5 K/W is 0.9 °F/W. A reader who forgets this may think a part performs worse than another listed in °C/W. The conversion is a straight multiplication by 1.8, with no 32-degree offset, because the quantity is a rise per watt and not a temperature reading. When you see °F/W next to a temperature in °F, keep the roles separate: the first is a resistance, and the second is a point on a scale.

Total resistance versus R-value

Thermal resistance in K/W belongs to an object as a whole, such as a heat sink or a pad of a given size. Building R-value is thermal insulance, resistance per unit area, written in m²·K/W or ft²·°F·h/Btu, and the two quantities are not interchangeable. A pad with 0.2 K/W and an area of 0.001 m² has an area-normalized resistance of 0.0002 m²·K/W. Multiplying by the area converts K/W into m²·K/W, and dividing does the reverse. This page does not include the area step. It stays within total resistance, so feed it values that already refer to a whole component.

Fan-cooled and passive heat sinks

A heat sink catalog usually lists resistance at one airflow and sometimes gives a curve against air velocity. A passive extrusion may list 2.5 °C/W in natural convection and 0.8 °C/W with forced air. Enter 2.5 with °C/W as the source and K/kW as the target and the page returns 2,500 K/kW, while 0.8 gives 800 K/kW. The ratio of about 3 between the two shows what a fan buys. For an illustrative 25 W load, the passive part gives a 62.5 K rise and the fan-cooled one 20 K. Neither value includes the thermal pad or the rise in air temperature inside an enclosure, so add those terms separately.

Limits when predicting temperatures

The result is a restated number, and a temperature prediction needs more: the power actually dissipated, the ambient temperature, airflow, mounting and whether the quoted value includes spreading. Manufacturers usually specify their values under particular test conditions, and real systems seldom match them. Use the page to bring figures into one unit, then apply the datasheet method for the temperature calculation, and keep a margin below the maximum junction temperature the component allows. For safety-related or product-qualification work, rely on measurement and the applicable standard instead of a calculation from catalog values.