Measurement basis
This quantity relates temperature difference to heat-transfer power.
Definition conventions
These units express temperature difference per power. Building R-value uses area-normalized thermal insulance.
Conversion method
Keep K/W unchanged; divide by a target thermal-resistance factor for another unit.
Reference equivalent of K/W
1 K/W = approximately 1 K/W.
Recorded scale factors: 1 for K/W; 1 for K/W.
Worked example
Known input: 10 K/W. Reference equivalent: 10 K/W. The return conversion gives approximately 10 K/W.
The example preserves a temperature-difference-per-power quantity.
Common reference values
| Input (K/W) | Reference equivalent (K/W) |
|---|---|
| 1 | 1 |
| 5 | 5 |
| 10 | 10 |
| 25 | 25 |
| 50 | 50 |
| 100 | 100 |
Compare one K/W with other units
| Target unit | Equivalent of 1 K/W | Definition guide |
|---|---|---|
| Kelvins per kilowatt (K/kW) | 1000 | Read definition |
| Fahrenheit degrees per watt (°F/W) | 1.8 | Read definition |
Degrees of rise per watt of heat
Kelvins per watt, K/W, tells you how much hotter one side of a thermal path becomes than the other for each watt flowing through it. A heat sink with a thermal resistance of 2 K/W warms 2 kelvins above its surroundings for every watt it dissipates. The unit is the SI form of thermal resistance, and its base units are K·s³·kg⁻¹·m⁻². Datasheets for transistors, regulators, processors and LEDs quote it as Rth or θ, and the symbol is often written in °C/W, which carries the same number because only temperature differences enter. K/W suits component-scale heat loads of fractions of a watt up to a few hundred watts.
Sizing a heat sink for a linear regulator
A common bench problem shows how the unit works. A linear regulator drops 12 V to 5 V at 0.5 A, so it dissipates 7 V × 0.5 A = 3.5 W. A TO-220 package without a heat sink typically has a junction-to-ambient resistance around 50 to 65 K/W, and 62.5 K/W would give a rise of 218.75 K, which is far beyond the limit. Adding a heat sink changes the path: junction to case 5 K/W, interface pad 0.5 K/W and heat sink to air 8 K/W add to 13.5 K/W. The rise is then 13.5 × 3.5 = 47.25 K, and in a 40 °C enclosure the junction reaches 87.25 °C, within a typical 125 °C limit.
Series and parallel in electronics
Thermal paths combine just as resistor networks do. Series layers, such as die, solder, case, thermal pad and heat sink, add. Parallel paths combine by adding conductances, so two 10 K/W paths together give 5 K/W. A circuit board with thermal vias adds a second path from a component to the copper plane in parallel with the path through the top of the package. When you estimate junction temperature, draw the path from the die to the air and list each resistance on it. The result is Tj = Tambient + P × (sum of resistances), and the sum can be checked against the datasheet value of junction to ambient, which already represents a standard test setup.
Relationship to thermal conductance
The reciprocal of thermal resistance is thermal conductance in W/K. A 0.5 K/W path conducts 2 W/K, so each extra kelvin of temperature difference moves two more watts. This is useful when a spec lists conductance and the calculation needs resistance, or when many paths are in parallel and conductances are easier to add. A heat sink for a 100 W load that must hold a 40 K rise needs a total resistance of at most 0.4 K/W, which is a conductance of at least 2.5 W/K. Neither form mentions the area of the surfaces, which means a given K/W value applies only to that exact part and mounting arrangement.
Conversion to K/kW and Fahrenheit
The converter on this site multiplies K/W by 1,000 to give K/kW and by 1.8 to give °F/W. A value of 0.25 K/W is 250 K/kW and 0.45 °F/W. In the reverse direction, 1 °F/W is 0.555555555556 K/W. Because a Celsius degree equals a kelvin in size, °C/W values copy straight across without change. These conversions matter when a heat sink catalog from one region meets a design reference from another. Work in K/W for component-level problems and in K/kW when the numbers are large enough that K/W would carry three leading zeros, such as in high-power inverter work.
Why published values are conditional
A junction-to-ambient figure from a datasheet applies to a specific board layout, airflow and orientation, commonly defined by a JEDEC test standard. Place the same package on a small board in still air and its resistance rises; put it on a large copper plane with a fan and it falls. A heat sink rated at 3 K/W in forced air at a stated speed might be 6 K/W or more in natural convection. Radiation and convection also change with temperature, so the resistance depends on the temperature difference itself. For design margins, take the datasheet value as a starting point, include a safety factor and, for critical products, verify with a measurement of the actual assembly.
LED and processor examples
Light-emitting diodes lose life and brightness when the junction runs hot, so lighting designers budget thermal resistance carefully. A 10 W LED module with a junction-to-board resistance of 3 K/W and a board-to-air resistance of 5 K/W has a total of 8 K/W, so the junction rises 80 K above the surrounding air, which in a 35 °C fixture reaches 115 °C, too high for most parts. Cutting the heat sink resistance to 2 K/W brings the total to 5 K/W and the junction to 85 °C. Processor coolers work the same way: a 95 W chip with a cooler of 0.3 K/W and a case-to-die path of 0.2 K/W rises about 47.5 K above the case air.
Transient behavior is not covered
Thermal resistance describes steady state, when heat flow and temperatures have stopped changing. Short pulses behave differently, because the material must first warm up, which involves heat capacity. For short bursts of power, datasheets give transient thermal impedance curves, written Zth, that start near zero and rise toward the steady-state resistance over milliseconds to seconds. A part that cannot handle 50 W continuously may still take a 50 W pulse of 1 ms. Using the steady-state K/W value for a pulse overestimates the temperature rise and may lead to oversized heat sinks. Use the K/W value for continuous loads and the transient curves for pulsed loads.
Resistance versus insulance
Building and materials work uses R-value, or thermal insulance, which includes area. Its SI unit is m²·K/W, and it describes a layer of unit area. Thermal resistance in K/W belongs to a specific component or assembly of a particular size, and dividing the insulance by the area gives the resistance of that surface. A wall section of 10 m² with insulance 3.5 m²·K/W has a resistance of 0.35 K/W. The two quantities are often confused because both are in K and W. When a source says R-3 or R-13, it is giving an insulance in US units, and it does not give K/W directly. Check the unit text and the area before converting.
Precision and checking
- Keep source resistance precision.
- Retain the stated system context.
Reference numbers are displayed with up to twelve significant digits. That display does not add precision to a rounded measurement. Keep source and target quantities compatible, confirm symbol case and regional conventions, and round the final result to precision justified by the input. Factors involving π or repeating fractions use finite numerical precision.
Use a working converter
- Thermal resistance converter
- Kelvins per watt to Kelvins per kilowatt converter
- Kelvins per watt to Fahrenheit degrees per watt converter
Source and verification scope
The reference values and examples use the versioned unit definitions shared with the linked converters. Source dates identify the stated access or verification scope. A reverse calculation checks arithmetic and direction, but it does not independently verify a definition. Computandum is independent of the cited organizations, and the citations do not imply endorsement of this guide or a real application.