Heat sink and cooler ratings in Fahrenheit terms
Heat sink listings, CPU cooler reviews and amplifier datasheets give thermal resistance in kelvins per watt or degrees Celsius per watt. A builder in the United States may still want the temperature rise in Fahrenheit, either to compare with a thermometer that reads Fahrenheit or to follow a guide written in those units. This page changes the rating itself, so you can multiply it by the power and get the rise in Fahrenheit degrees directly. It also accepts Celsius per watt and kilowatt-based values in the menus. The conversion covers the unit only. It does not tell you whether a given cooler is large enough for your part or your case.
A factor of 1.8 and nothing else
One kelvin of temperature difference equals 1.8 degrees Fahrenheit, because 100 Celsius degrees span the same range as 180 Fahrenheit degrees between the freezing and boiling points of water. Thermal resistance divides a temperature difference by a power, and the power unit stays the watt, so the rating gets multiplied by 1.8. No 32 or 459.67 is added, since those numbers belong to temperature readings and not to differences. To go back, divide by 1.8, so 18 °F/W returns 10 K/W. A degree Celsius per watt has the same size as a kelvin per watt, so the same factor applies to it.
The opening value of 10 K/W
The page opens on 10 K/W and returns 18 °F/W. Each watt flowing through that path adds 10 K, or 18 °F, to the temperature difference between the two ends. A resistance of 10 K/W is high, the kind of value seen on a tiny component in free air with no heat sink. Ten watts through it would be a rise of 100 K, or 180 °F, which is why such parts are not run near their power limit without cooling. The example is worth keeping in mind as a quick sanity test: any output should be 1.8 times the input, larger by 80 percent, and an answer that is smaller means the menus are reversed. A second check is the 10 K/W anchor itself: any resistance of 5.56 K/W should land close to 10 °F/W, which makes a quick mental scale for later values.
Estimating a processor temperature rise
Consider a processor cooler with a rating of 0.3 K/W under a 65 W load. The rise is 0.3 × 65 = 19.5 K, which is 35.1 °F. In per-watt form the rating becomes 0.54 °F/W, and 0.54 × 65 gives the same 35.1. Add the rise to the air temperature inside the case, not to the room, because the cooler pushes heat into case air that is already warmer. If that air measures 95 °F, the estimate for the heat source at the cooler is about 130.1 °F. Real systems add contact resistance between the chip and the cooler base, and thermal paste is rated separately. Treat the result as a lower bound on the rise, and expect a measured value to come out higher when the contact layer and the case airflow are included.
Common values on datasheets
Small power transistors in a TO-220 package have junction-to-ambient resistances in the range of tens of K/W with no sink. Large aluminum heat sinks reach values below 1 K/W, and well-ducted fan coolers go lower. Passive sinks are usually rated for still air and a stated orientation, and a fan can lower the figure by a large share, so look for the airflow condition behind each number. A rating of 2.5 K/W converts to 4.5 °F/W, 1.2 K/W to 2.16 °F/W and 0.25 K/W to 0.45 °F/W. Values below 1 convert to numbers that are also below 2, so the Fahrenheit figure still looks small. Always keep the qualifier from the datasheet, such as junction to case or sink to ambient, because the same device has several different resistances along its heat path. When you copy a value into a spreadsheet, put the qualifier in the next column so that nobody adds a case-to-ambient value to a junction-to-case value by accident.
Adding the pieces of a heat path
Series resistances add. A transistor with 1.5 K/W from junction to case, a mounting pad of 0.5 K/W and a sink of 2 K/W has a total of 4 K/W, which is 7.2 °F/W. Converting each piece first gives 2.7, 0.9 and 3.6 °F/W, and the sum is again 7.2. Keep every term in a single unit before adding, and do not mix K/W and °F/W in one column. With a 12 W load the total path adds 48 K, or 86.4 °F, above the surrounding air. If the part has a maximum junction temperature, subtract the ambient and compare the allowed difference with this rise.
Fahrenheit differences versus Fahrenheit temperatures
The most frequent error in this area is adding an offset where none belongs. A rise of 35.1 °F is a change in temperature, and it is added to a starting temperature in Fahrenheit. It is not converted again with the 32-degree rule. For instance, adding 35.1 to a case temperature of 95 °F gives 130.1 °F. If you convert the rise as if it were a reading, you would get a result that no thermometer could show. This page works only with the per-watt rating, so any offset belongs to the temperature values you add afterward.
Sizing a sink for an amplifier or LED driver
Hobby electronics guides often ask how large a heat sink must be. Suppose a linear regulator dissipates 6 W and the part may not rise more than 90 °F above the air around it. The allowed resistance from junction to air is 90 / 6 = 15 °F/W, which is 8.33 K/W after dividing by 1.8. Every part of the path must fit inside that budget, so a package with 5 K/W and a pad of 0.5 K/W leaves about 2.83 K/W for the sink. Shopping then becomes a matter of finding a sink listed at or below that figure. Doing the budget in Fahrenheit and the sink search in kelvins per watt is exactly where this converter is useful.
Boundaries of the page
The converter changes units for one number. It does not estimate airflow, fin efficiency, contact pressure or how a rating changes with temperature and load. It does not apply to building insulation, which uses a per-area quantity called R-value. The output carries many decimals, and you can round it to match the precision of your source. Treat a datasheet value as valid for the test setup that produced it, and check the manufacturer for mounting details when a part runs near its rating.