Heat sink catalogs and older US documents
Heat sink catalogs, semiconductor datasheets and thermal simulation tools almost always list resistance in K/W or °C/W. Fahrenheit versions turn up in older American manuals, in some HVAC and process equipment literature and in notes written by people who think in Fahrenheit. When one of those values has to be compared with a modern datasheet, it must be restated in kelvins per watt first. This page does that restatement for a single value. It is not a temperature converter, and it has no offset. It is a ratio converter for the quantity temperature rise per watt of heat flowing through a part, a joint or a whole assembly. The same ratio works for a single thermal interface pad, a finned extrusion or a complete enclosure, as long as the heat flow and the temperature difference refer to the same two points.
Where 5/9 comes from
Fahrenheit and Celsius degrees differ in size. Between the freezing and boiling points of water at standard pressure there are 180 Fahrenheit degrees and 100 Celsius degrees, so one Fahrenheit degree is 100/180, or 5/9, of a Celsius degree. The kelvin has the same size as the Celsius degree. Thermal resistance has temperature in the numerator, so multiplying by 5/9 converts it. The factor shown on the page, 0.555555555556, is that fraction rounded to twelve digits. Because the denominator unit is the watt in both systems, no second factor is needed, unlike the conversion to K/kW on the sister page.
The default of 10 °F/W
With the starting value of 10, the converter shows 5.556 K/W. In practical terms, a part with that resistance warms by about 5.6 K for every watt of heat that passes through it. Pushing 10 W through it produces a rise near 55.6 K, which is a 100 °F rise, and 20 W doubles that to 111.1 K. A value of 10 °F/W is on the high side for a heat sink and closer to a small plastic package in still air, so the default works well as a demonstration of scale rather than as a typical part. Doubling the entry to 20 °F/W gives 11.111 K/W, and halving it to 5 °F/W gives 2.778 K/W.
A lamp heat sink and a 40 W load
Suppose an old US catalog lists a bar heat sink for LED lamps at 2.7 °F/W. The conversion gives 1.5 K/W exactly, since 2.7 × 5/9 = 1.5. A 40 W lamp driver dissipating its full power into that sink would raise the sink surface 60 K above the surrounding air, which is a 108 °F rise. With an ambient of 25 °C, the sink would sit near 85 °C. Going the other way, a modern 0.8 K/W aluminum extrusion is 1.44 °F/W, found by multiplying by 1.8. The lamp and the extrusion are illustrative numbers chosen to make the arithmetic visible. The Fahrenheit reading of the rise, 108 °F, is also 1.8 times the kelvin figure, which is the same factor as the reverse unit conversion.
Series resistances in one unit
A thermal path is usually several resistances in series: the semiconductor junction to its case, the interface material, the heat sink and sometimes a spreader plate. They add only when every term is in the same unit, so converting every Fahrenheit entry to K/W before summing is the safe order. As an example, 0.5 K/W from junction to case, 0.2 K/W for the interface and 1.1 K/W for the sink total 1.8 K/W. That equals 3.24 °F/W, so a Fahrenheit-based note giving a total of 3.24 °F/W matches this stack. Use the page for each entry and then add the K/W values together. If you prefer to finish in Fahrenheit, convert the total back, and expect the same answer to within rounding.
Why °C/W and K/W are the same number
The converter lists Celsius degrees per watt next to kelvins per watt. For a resistance, the two are numerically identical because a temperature difference of one Celsius degree equals one kelvin. Datasheets mix them freely, and a heat sink listed at 1.2 °C/W is 1.2 K/W. Only the Fahrenheit value needs a factor. If you are working from a datasheet that says °C/W and want Fahrenheit, multiply by 1.8, and if you have Fahrenheit and want either SI form, multiply by 5/9 as this page does.
From a watt rating to a temperature rise
Once the resistance is in K/W, the steady-state rise is power times resistance, so a part of 1.5 K/W carrying 12 W is 18 K warmer than its cold side. The cold side has to be a defined reference, such as the case, the heat sink base or the ambient air, and the resistance must be the one measured to that same reference. Mixing a junction-to-case value with an ambient temperature leaves out the sink and interface and gives a rise that is too small. The converter gives you the number to use but does not decide which reference applies.
Fahrenheit rise targets in a specification
Sometimes the Fahrenheit number is a limit and not a resistance. A US specification may allow a surface rise of 63 °F at rated power, and you want the K/W budget that results. A rise limit of 63 °F is 35 K, because 63 × 5/9 = 35. With 25 W of loss the allowed resistance from the surface to ambient is 35 / 25 = 1.4 K/W, which equals 2.52 °F/W. Working the budget in K/W, then converting the final answer back with this page for the Fahrenheit-speaking reader, keeps the reasoning in one consistent unit. Remember that the rise limit is an interval and uses 5/9, whereas a limit on an absolute surface temperature would need the temperature converter and its offset.
Thermal resistance values versus temperature results
The page converts a stored resistance value. It does not calculate temperatures, derating, airflow effects or compliance with any standard. Thermal resistance also depends on conditions that the number alone hides, such as airflow speed, mounting orientation and power level, so a value taken from one test setup may not match your enclosure. The assumption behind the tool is a total thermal resistance in temperature difference per power, which is different from the area-based R-value used for building insulation. Check the source of the original value before you convert and use it. Look for the test method, the airflow and the reference point the number was measured against, because a resistance quoted without them cannot be matched to your design.