Moving a CGS reading into SI
Magnetic field strength H is stated in oersteds in older textbooks, many magnet and sensor data sheets and the display of some bench instruments. Journals, European standards and most modern simulation software work in amperes per meter. Whenever the two meet, such as a hobby project that compares a sensor datasheet with a finite-element model, one of the numbers has to be converted. This page multiplies oersteds by 79.5774715459 and returns A/m. It is meant for students, engineers and makers who read an oersted figure and need an SI value for a formula, a simulation input or a report that follows the SI Brochure from the BIPM.
The origin of 1,000/(4π)
In the CGS electromagnetic system the oersted is defined so that the field inside a long solenoid is 4π/10 times the current in amperes per centimeter of winding, expressed in oersteds. Working that into SI gives 1 Oe = 1,000/(4π) A/m. The value 79.5774715459 contains π, so its decimal expansion does not end, and the page stores a rounded form. NIST SP 811 gives the equivalent. A rough memory aid is that 1 Oe is close to 80 A/m, and 1 A/m is about 0.01257 Oe. A drop in the number when going from oersteds to A/m is the signature of swapped menus.
Ten oersteds is about 796 A/m
The default of 10 Oe returns 795.7747154594767 A/m. In a document you would round this to 796 A/m or 795.8 A/m, depending on what the source supports. The page keeps many digits so that a chain of calculations does not lose precision in the middle, and you cut the result at the end. If the same value feeds a later formula, paste the long form into the spreadsheet cell and format the display separately. Other inputs scale directly: 1 Oe gives 79.57747 A/m, and 25 Oe gives 1,989.437 A/m. The numbers in A/m are larger than the numbers in Oe, which is a reminder that the SI unit is a smaller measure of field. Always write the unit with the figure, so that A/m is not confused with A/cm.
The Earth field and a compass
The magnetic field of the Earth at the surface is roughly 0.5 oersted in air, which is 0.5 gauss or about 50 µT. Entered in the page, 0.5 Oe gives 39.78874 A/m. A small magnet near a compass can easily produce more than that, which explains why a compass reads wrongly near a speaker or a steel desk. Hobby magnetometers and phone sensors report the field in microtesla, so a value in A/m from this page may need a further step. In air, a field of 39.79 A/m corresponds to 50 µT because B is the permeability of free space times H. The page itself stops at A/m and does not perform that second step.
Soft magnetic cores and low coercivity
Soft magnetic materials such as electrical steels, mu-metal and ferrite cores are chosen for low coercivity, the reverse field needed to bring the magnetization to zero. Data sheets for these materials may state it in A/m or in oersteds, and values of a fraction of an oersted are common for the best alloys. A coercivity of 0.3 Oe converts to 23.87324 A/m. The illustrative number shows how a small value in oersteds can look large in A/m without any change in physics. When you compare two materials, make sure that both are in the same unit and that the same measurement frequency or method is stated, because coercivity depends on how it was determined.
From amperes per meter to oersteds
Choose A/m as the source and oersteds as the target to read an SI value on a CGS scale. A field of 8,000 A/m is 100.531 Oe, and 1,000 A/m is 12.56637 Oe. The page divides by 79.5774715459, so the answer is a smaller number than the one you entered. This direction helps when a simulation outputs field strength in A/m and you want to compare it with a probe that reads in oersteds. The rounding rule is the same in both directions: keep as many digits as your least precise number supports and no more, then check the result by converting it back.
Oersted, gauss and tesla in air
The oersted is a unit of H and the gauss is a unit of B, yet in air the CGS numbers coincide. So 10 Oe in air corresponds to 10 G, which is 1 mT, and the matching H in SI is 795.7747 A/m. The relation B = µ0 × H, with µ0 equal to 4π × 10^-7 H/m, gives the same result: 795.7747 × 4π × 10^-7 is about 0.001 T. Inside iron or a magnet, B and H are no longer proportional by that constant. The page converts only H, and any step that brings in a material needs the permeability or a measured curve.
Choosing digits and scale
A/m numbers can be large, and kA/m may be easier to read. A field of 1,989.437 A/m is 1.989437 kA/m, and there is a separate converter for oersteds to kA/m. When you write a result, choose the unit that keeps the number between 1 and 1,000 and give the digits that match your measurement. A hand-held probe may be good for two or three digits, so 796 A/m is a sensible way to record 10 Oe. A value written as 795.7747 A/m would suggest a precision of one part in a million, which no hand-held probe provides. The more digits you quote, the more a reader will assume you measured, so do not copy the full output of the page into a report.
H in oersteds against B in gauss between two documents
The field of a particular coil or magnet, the response of a material, a safe exposure level and the position of a probe are not supplied by a unit rescale. Field values vary with distance, so a number without a position can mislead. For design work, use the equations for your geometry and the data sheet for your material, and measure when accuracy matters. The converter keeps units consistent between sources, and it cannot tell which source is right. When two documents disagree after conversion, look first at whether one of them quotes B in gauss and the other H in oersteds, since that mix-up is more common than an arithmetic error.