Reading a paper that mixes units

Hysteresis loops from vibrating-sample magnetometers, recording-media papers and many thin-film studies plot field in oersteds, while standards and newer articles use A/m. Someone writing a report in SI has to convert each field value. The numbers are small in oersteds for the same field, since one oersted is a rather large 79.58 A/m. The page performs the conversion with the exact constant, which spares you from remembering whether to multiply by 4π or divide by it. It also handles the reverse direction, so a coercivity given in oersteds can be restated in A/m for a table that follows SI practice. When a value appears in both oersteds and A/m in the same paper, use it to verify that the factor you apply gives the author number. Spreadsheets handle this well: store the raw oersted column untouched and add a converted column with the constant in its own labeled cell.

The constant 4π / 1,000

By definition, 1 Oe equals 1,000 / (4π) A/m, about 79.5775 A/m. The reciprocal, 4π / 1,000, is 0.01256637, the factor on this page. A field of 10 A/m is therefore 0.1256637 Oe, and 1,000 A/m is 12.566 Oe. The factor contains π because the CGS system defines magnetic units to remove a 4π from certain equations, and the SI places that constant elsewhere. A rough way to remember it is that 80 A/m is about 1 Oe and, going the other way, one oersted is about 80 A/m, which is accurate to within 0.5 percent. To see why the constant sits where it does, note that 1 Oe is 1,000 divided by 12.566, which is 79.58, and that 12.566 is 4π.

Bench readings and typical values

A background reading of 40 A/m on a phone magnetometer or a workshop probe converts to 0.50266 Oe, so an empty room reads about half an oersted, or half a gauss in air. A permanent bar magnet may produce a few hundred oersteds near its pole, and a coil in a lab setup a few tens. Converting those to A/m gives tens of kA/m and thousands of A/m. Having both numbers in mind lets you read old literature without reaching for a table, and the converter provides the exact value when you need to cite it. Shielding specifications sometimes state a residual field in oersteds, so a target of 0.01 Oe corresponds to about 0.8 A/m.

Hysteresis loops and coercivity

A thin magnetic film might show a coercivity of 80 A/m on a loop plotted in SI, which is 1.005 Oe. Another sample with 400 A/m has 5.03 Oe. Switching the plot units changes the axis labels and the scale but not the physical loop. If you replot data from an oersted loop in A/m, multiply every field value by 79.5775. For a field sweep from minus 500 Oe to plus 500 Oe, the equivalent SI range is about minus 39,789 to plus 39,789 A/m. Keep the axis label consistent with the unit used and mention the conversion in the figure caption. The same method applies to saturation fields and switching fields quoted in oersteds for magnetic recording media.

Gauss and tesla are separate quantities

The oersted is the unit of H in the Gaussian system, and the gauss is its unit of B. In air a field of 1 Oe corresponds to a flux density of 1 G, which is 0.1 mT, and many gaussmeters are used as if they read oersteds. That equivalence breaks down inside magnetic materials and in mixed unit systems. If you hold a value in A/m and want to check it against a gaussmeter in air, convert to oersteds with this page and read the number as gauss. The page itself does not convert to gauss or tesla, and the result stays a field strength.

Checking with a gaussmeter

A bench gaussmeter reads flux density B, and in air that value in gauss is numerically the same as H in oersteds. To check a coil designed for 400 A/m, convert to oersteds with this page, which gives 5.03 Oe, and expect a gaussmeter reading near 5.03 G, or 0.503 mT. Differences larger than the probe accuracy suggest an error in the coil model, the probe position or the current. Hall probes drift with temperature, so allow a warm-up period and zero the probe in a shielded space. The converter only supplies the expected reading, and the comparison is a measurement task.

Reverse conversion in practice

Going from oersteds to A/m multiplies by 79.5775. A field of 100 Oe is 7,957.7 A/m, which is 7.96 kA/m, and 1 Oe is 79.58 A/m. Using the dropdowns in the converter lets you check this without handling π. For a quick estimate in a meeting, 1 Oe is approximately 80 A/m, and the error of this shortcut is about 0.5 percent, small compared with typical measurement uncertainty. If you are reporting a standard value, use the exact factor from the page and give enough digits so that the reader can reproduce your conversion. When writing the result in a table, give the oersted equivalent in parentheses beside the SI value so both audiences can follow it. Using both forms side by side also helps reviewers who compare your numbers with older work.

Rounding the irrational oersted factor

The conversion factor is irrational, so the displayed result is always rounded. For the default, 0.1256637061435917 is more digits than any measurement supports, and 0.126 Oe or 0.1257 Oe is a fair statement of the value. Watch out for the 1.26 and 0.0126 shortcuts, which differ from the exact figure by about 0.3 percent. Over a wide field range that error is noticeable on a plot. When a figure is to be compared with another one that used a different rounding, convert both from the original data rather than from rounded intermediate values. Quote the factor you used in a footnote when the result feeds a published figure.

Flux density and material limits

The page re-expresses a field strength in a different unit. It does not compute a field, convert to flux density, test a material or decide whether a device is suitable. As the assumptions state, it does not calculate installation limits, equipment ratings, protection, material response or compliance. Strong magnetic fields can interfere with medical devices and electronics, and any decision of that sort rests on the manufacturer instructions and the applicable standards. Very weak fields, such as those in magnetically shielded rooms, are better handled in nanotesla or picotesla units than in oersteds.