Measurement basis
No universal ampere-per-meter to tesla conversion is provided. Relating those quantities requires permeability under a material model.
Definition conventions
The oersted factor is 1000/(4π), with a finite decimal representation.
Conversion method
Use the compatible H-unit ratio, keeping the π-based factor precision until the final result.
Choose the conversion direction
Confirm an H field-strength unit in the source before selecting the receiving H unit.
The H field in amperes per meter
Magnetic field strength, written H, is measured in amperes per meter in the SI. It describes the magnetizing field produced by electric current, as opposed to the total magnetic response of a material. In Ampere law, the line integral of H around a closed path equals the current enclosed, and that is why the unit is current per length. A long solenoid with n turns per meter carrying current I produces a field H = nI inside it. With 1000 turns per meter and 2 A, H is 2000 A/m. The material in the core does not change this value. It changes the flux density B that results.
How H differs from B
Flux density B, in teslas, and field strength H, in amperes per meter, are related by B = μ0(H + M), where M is the magnetization of the material and μ0 is about 1.2566 × 10^-6 N/A². In vacuum or air, M is negligible, so B is approximately μ0 times H. An H of 1000 A/m in air corresponds to a B of about 1.2566 mT. In iron, the same H can give a B larger by a factor of hundreds or thousands. Treating a reading in A/m as a reading in tesla, or the reverse, is the most common confusion, and the two are different quantities, not different units of one quantity.
Prefixes and the ampere per centimeter
Within the SI, 1 kA/m is 1000 A/m. Datasheets for magnetic materials often use A/cm, where 1 A/cm equals 100 A/m, because a centimeter is one hundredth of a meter and the length is in the denominator. A coercivity listed as 0.8 A/cm is 80 A/m. Magnetic measurement of soft materials such as transformer steel often involves values from a few A/m to some hundreds of A/m. Permanent magnets such as neodymium grades have intrinsic coercivities of order 1000 kA/m or more. The prefix scale therefore spans six orders of magnitude, so notation like 955 kA/m must be read for its prefix.
The oersted from the centimeter-gram-second system
The oersted, symbol Oe, is the unit of H in the older Gaussian system. It is named for Hans Christian Ørsted, who in 1820 showed that an electric current deflects a compass needle. One oersted equals 1000/(4π) A/m, about 79.5775 A/m. So 10 Oe is about 795.8 A/m, and 1 kA/m is about 12.566 Oe. In vacuum, a field of 1 Oe goes with a flux density of 1 gauss. Magnet manufacturers and older research papers still quote coercivity in oersteds or kilo-oersteds, and a typical NdFeB magnet may be listed above 12 kOe, which is above 950 kA/m.
Earth field and electromagnet values
Earth magnetic flux density near the surface is about 25 to 65 µT. Dividing by μ0 gives an H of roughly 20 to 50 A/m, so 50 µT corresponds to about 39.8 A/m, or 0.5 Oe. A strong electromagnet in a laboratory may produce an H of several hundred kA/m in a gap. Wire carrying 100 A creates an H of 100 / (2π × 0.1) ≈ 159 A/m at a distance of 10 cm. The result, about 2 Oe, is stronger than Earth field, and that explains why a compass near heavy direct-current cabling can misread. Numbers like these help a reader sanity-check a value found in a datasheet.
Hysteresis loops and coercivity
In a magnetic material, B does not follow H along a single curve. The hysteresis loop shows that the response depends on history. The H needed to bring B back to zero after saturation is called the coercivity, and it distinguishes soft materials, with a few A/m, from hard materials, with hundreds of kA/m. Standards for magnetic measurement, including IEC documents on soft magnetic materials, report field strength in A/m. If a material card lists coercivity in oersteds and another in A/m, multiplying by 79.5775 compares them. This is a unit conversion of H only, since the loop shape and material comparison involve more than one number.
Field strength around cables and coils
Exposure guidance for low-frequency magnetic fields is usually given in flux density, in microtesla, though some older and national documents quote H. The conversion uses μ0 only in free space, which is a good approximation for biological tissue and air. A guidance value of 80 A/m is about 100 µT. Coil designers work the other way and choose an H to achieve a target flux density, adding a core when needed. Because current and distance both enter through H = I / (2πr) for a straight wire, doubling the distance halves the field, which gives a quick feel for how steeply it falls away. At 1 m from the same 100 A wire the field is about 15.9 A/m, which is less than half of Earth field strength of about 40 A/m.
Symbols and what a converter can do
The symbol is H in italic for the quantity and A/m for the unit. Not to be confused with the henry, also written H when upright. Amperes per meter are sometimes written as A·m^-1. A conversion between A/m, kA/m, A/cm and Oe is a fixed multiplication, and the SI part is exact, while the oersted factor involves π and is rounded in display. The converter does not turn H into B, because that needs the material or a vacuum assumption, and it does not estimate shielding, exposure limits or any compliance question. It restates the same field strength in another unit.
Worked conversions in both directions
Because the oersted factor is 1000/(4π), conversions are easy to check by hand. A coercivity of 955 kA/m divided by 79.5775 per oersted is about 12.0 kOe, which matches magnet datasheets that list both. A field of 5 Oe is 5 × 79.5775 = 397.9 A/m. An H of 250 A/m is about 3.14 Oe, and 1 A/cm is about 1.2566 Oe. Magnet coercivity falls as temperature rises, so a value quoted at 20 degrees Celsius does not apply to a motor running hot. Mixed tables are common in magnet catalogs, where one column gives kA/m and another gives kOe for the same grade, and checking one row by hand confirms whether the whole table is consistent. A mistake in the factor of 4π shows up as a result about 12.6 times too large or small, which is a useful signal when a figure looks implausible.
Precision and checking
- Retain source field-strength precision.
- The oersted factor is not an exact finite decimal.
Reference numbers are displayed with up to twelve significant digits. That display does not add precision to a rounded measurement. Keep source and target quantities compatible, confirm symbol case and regional conventions, and round the final result to precision justified by the input. Factors involving π or repeating fractions use finite numerical precision.
Choose a unit definition
Amperes per meter (A/m)
Definition, reference values and linked conversions.
Kiloamperes per meter (kA/m)
Definition, reference values and linked conversions.
Amperes per centimeter (A/cm)
Definition, reference values and linked conversions.
Oersteds (Oe)
Definition, reference values and linked conversions.
Use a working converter
- Magnetic field strength converter
- Amperes per meter to Kiloamperes per meter converter
- Kiloamperes per meter to Amperes per meter converter
- Amperes per meter to Amperes per centimeter converter
- Amperes per centimeter to Amperes per meter converter
- Amperes per meter to Oersteds converter
Source and verification scope
The reference values and examples use the versioned unit definitions shared with the linked converters. Source dates identify the stated access or verification scope. A reverse calculation checks arithmetic and direction, but it does not independently verify a definition. Computandum is independent of the cited organizations, and the citations do not imply endorsement of this guide or a real application.