Measurement basis
Its recorded factor is 100 A/m.
Definition conventions
The oersted factor is 1000/(4π), with a finite decimal representation.
Conversion method
Multiply A/cm by 100 for the reference field strength.
Reference equivalent of A/cm
1 A/cm = approximately 100 A/m.
Recorded scale factors: 100 for A/cm; 1 for A/m.
Worked example
Known input: 10 A/cm. Reference equivalent: 1000 A/m. The return conversion gives approximately 10 A/cm.
The calculation rescales the denominator length.
Common reference values
| Input (A/cm) | Reference equivalent (A/m) |
|---|---|
| 1 | 100 |
| 5 | 500 |
| 10 | 1000 |
| 25 | 2500 |
| 50 | 5000 |
| 100 | 10000 |
Compare one A/cm with other units
| Target unit | Equivalent of 1 A/cm | Definition guide |
|---|---|---|
| Amperes per meter (A/m) | 100 | Read definition |
| Kiloamperes per meter (kA/m) | 0.1 | Read definition |
| Oersteds (Oe) | 1.25663706144 | Read definition |
A field strength written per centimeter of path
Amperes per centimeter, A/cm, measures magnetic field strength, the quantity H. The SI unit is the ampere per meter, A/m, and because a centimeter is one hundredth of a meter, 1 A/cm equals 100 A/m. Dividing by a smaller length gives a larger number, so a field of 25 A/cm is 2,500 A/m. The unit comes straight from Ampère's circuital law: current enclosed, divided by the length of the path around it. Magnetics datasheets for cores, inductors and electromagnets sometimes use A/cm because the path lengths of small cores are quoted in centimeters. On a small core with a 6 cm magnetic path, 120 ampere turns give 20 A/cm.
H is the field produced by currents, B is the response of a material
Magnetic field strength H and magnetic flux density B are different quantities. H depends on the currents and the geometry. B also depends on the material, through B = μ0 (H + M), where M is the magnetization. In vacuum, B = μ0 H, and the magnetic constant μ0 is about 1.25663706 × 10⁻⁶ N/A², which is the same as 1.25663706 × 10⁻⁶ H/m. A field of 100 A/cm, or 10,000 A/m, therefore corresponds to a flux density of about 12.566 mT, or 125.66 gauss, in air. In a ferromagnetic core the same H can produce a B hundreds or thousands of times larger. Converting A/cm to tesla needs the material relation and is not a unit change.
A solenoid example with turns, current and length
For a long solenoid, H inside is the number of turns times the current, divided by the length: H = N I / l. A coil of 500 turns carrying 2 A on a form 10 cm long has H = 500 × 2 / 0.10 m = 10,000 A/m, which is 100 A/cm. Halving the length doubles H, and doubling the current doubles it as well. Often a designer works in ampere turns per centimeter, since the number of turns is dimensionless and the ampere-turn is the practical unit of magnetomotive force. A magnetic circuit rated at 80 A/cm over a path of 12 cm needs 960 ampere turns, ignoring any air gap.
The oersted and the CGS system
In the older CGS unit system, magnetic field strength is measured in oersteds, named for Hans Christian Ørsted. One oersted equals 1,000/(4π) A/m, about 79.5775 A/m. Therefore 1 A/cm equals 100 / 79.5775 = 1.25664 Oe, and 1 A/m is 0.0125664 Oe. A field of 40 A/cm is 50.27 Oe. The numerical coincidence between oersteds and gauss in vacuum, where 1 Oe corresponds to 1 G, is a feature of CGS and does not carry over to SI. Papers from before about 1980, especially on magnetic materials, may give H in oersted and B in gauss, which is why a conversion table that includes A/cm is useful. Ampere turns measure magnetomotive force and carry no length, while gauss and tesla measure B, which has a different dimension from H. The gilbert, the CGS unit of magnetomotive force, equals 10/(4π) ampere turns, about 0.7958 A, and a gilbert per centimeter equals an oersted.
Soft and hard magnetic materials and their coercivity
Datasheets for magnetic materials report coercivity, the reverse field needed to bring the magnetization to zero, in A/m, kA/m or A/cm. Soft materials such as electrical steels and nickel-iron alloys have very low coercivity, from a fraction of an A/cm to a few A/cm, so they magnetize and demagnetize easily in transformer cores. Hard materials like neodymium-iron-boron magnets have coercivities of hundreds to thousands of kA/m, equal to thousands or tens of thousands of A/cm. The values vary with grade and temperature, so the numbers here are orders of magnitude only. Grain-oriented silicon steel is commonly graded by its flux density at 800 A/m, which is 8 A/cm, and good grades exceed 1.8 T there. A listed figure of 3 A/cm equals 300 A/m, which is typical of a good soft material.
Earth's field and everyday magnitudes
The Earth's magnetic field at the surface has a flux density of roughly 25 to 65 µT depending on location. In air this corresponds to an H of about 20 to 52 A/m, or 0.2 to 0.52 A/cm. A compass needle responds to that weak field. A small permanent magnet might produce several hundred A/cm at its surface, while a laboratory electromagnet can reach 10,000 A/cm or more near its pole faces. An MRI scanner at 3 T has a flux density that in free space corresponds to H of about 2.39 million A/m, or 23,900 A/cm. A flux density of 5 mT in air, typical of a refrigerator magnet's surface, corresponds to about 40 A/cm.
Denominator errors between A/cm and A/m
The factor between the units is 100, and the direction is easy to get wrong because the length unit is in the denominator. If you are converting a length in the numerator, such as from centimeters to meters, you divide by 100. In a denominator, the same length conversion multiplies by 100. A core datasheet that says H = 5 A/cm means 500 A/m, and writing 0.05 A/m is the mistake that results from treating the centimeter as if it were in the numerator. A field of 1 A/cm gives a flux density of 1.2566 × 10⁻⁴ T, or 1.2566 gauss, in air. A quick check is to ask whether the same current is spread over a short path or a long one, since shorter paths always produce stronger fields. Some texts call H the magnetizing field or the magnetic field intensity, and electromagnet design often lists ampere turns per centimeter, written At/cm. The SI Brochure lists the ampere per meter for magnetic field strength and gives it no special name.
Sizing an electromagnet coil from a target field
Suppose a gap of 2 mm in a magnetic circuit needs a flux density of 0.4 T. Neglecting the core, H in the gap is 0.4 / 1.25663706 × 10⁻⁶ = 318,310 A/m, or 3,183 A/cm, and over 2 mm that calls for 637 ampere turns. A winding of 200 turns would then carry 3.18 A. Add the path inside the iron, at perhaps 5 A/cm over 15 cm, and 75 more ampere turns are needed. The total is 637 + 75 = 712 ampere turns, or 3.56 A in the 200-turn winding. The numbers are illustrative, and real designs include leakage and saturation margins.
Precision and checking
- Keep measured field-strength precision.
- Retain cm in the denominator.
Reference numbers are displayed with up to twelve significant digits. That display does not add precision to a rounded measurement. Keep source and target quantities compatible, confirm symbol case and regional conventions, and round the final result to precision justified by the input. Factors involving π or repeating fractions use finite numerical precision.
Use a working converter
- Magnetic field strength converter
- Amperes per centimeter to Amperes per meter converter
- Amperes per centimeter to Kiloamperes per meter converter
- Amperes per centimeter to Oersteds converter
Source and verification scope
The reference values and examples use the versioned unit definitions shared with the linked converters. Source dates identify the stated access or verification scope. A reverse calculation checks arithmetic and direction, but it does not independently verify a definition. Computandum is independent of the cited organizations, and the citations do not imply endorsement of this guide or a real application.