Two systems for one field

Magnetic field strength is written in A/m in the SI and in oersteds in the older CGS-Gaussian system. Textbooks, magnetic recording papers, vibrating-sample magnetometer plots and some material specifications still use oersteds, while newer or European sources use A/cm or A/m. A reader who finds a coercivity of 25 Oe in a paper and a requirement in A/cm in a standard has to reconcile them. This page does it with the exact relation between the two units. Datasheets for ferrite cores and magnetic recording media often list coercivity this way, so a quick conversion keeps a purchase specification and a lab result on one scale. Journals in magnetics have moved toward SI over the years, but many authors still report oersteds, so the conversion remains a daily task for reviewers and students. Since 1 Oe equals 1,000/(4π) A/m, about 79.577 A/m, one ampere per centimeter, which is 100 A/m, comes to about 1.2566 Oe.

Where 4π comes from

The CGS unit system defines magnetic quantities with factors of 4π built into the equations, and the SI uses a different convention. That is why the conversion is not a pure power of ten. By definition, 1 Oe is 1,000 / (4π) A/m, which is about 79.5775 A/m, or 0.795775 A/cm. Inverting, 1 A/cm is 4π / 10 Oe, which is 1.25663706 Oe. The page shows 12.566370614359172 for 10 A/cm. The number 4π / 10 is irrational, so the result never terminates, and any displayed value is rounded.

The default and a pair of handy values

Ten amperes per centimeter is 12.566 Oe. Five A/cm is 2π Oe, about 6.2832, since 5 × 4π / 10 is exactly 2π. One A/cm is 1.2566 Oe, and 100 A/cm is 125.66 Oe. For the reverse direction, 20 Oe converts to 15.915 A/cm, and 1 Oe is 0.7958 A/cm. A quick estimate is that oersteds are about 25 percent larger in number than A/cm, since 1.2566 is the factor. Keeping this ratio in mind catches an inverted conversion, because the oersted number must always be the bigger one for the same field. Check one more: 50 A/cm is 62.83 Oe, which is 20π, and 0.5 Oe is 0.3979 A/cm.

Oersted and gauss are different quantities

In the Gaussian system, the oersted measures field strength H and the gauss measures flux density B, and in vacuum a field of 1 Oe is accompanied by a flux density of 1 G. That numerical coincidence leads people to treat the two units as interchangeable. They are not. In a material, B and H differ by the permeability, and the relation can be strongly nonlinear. SI keeps them apart more clearly, with A/m for H and tesla for B. This page converts H only, from A/cm to Oe, and does not give a flux density. One gauss is 10^-4 T, and one oersted is not a tesla in any form. Keep in mind that a gaussmeter measures B, so reading its display as an oersted figure is a shortcut valid for air only.

Soft magnetic materials in oersteds

The coercivity of soft magnetic materials is often quoted in oersteds. Good soft ferrites and nickel-iron alloys may have coercivities well below 1 Oe, while ordinary low-carbon steel is in the range of a few oersteds, and hard magnets are in the thousands. Converting a typical soft-material value of 0.5 Oe gives 0.398 A/cm, or 39.8 A/m, which is about the strength of the Earth field at the surface. If you work with a magnetic shield, a value such as 0.5 Oe is therefore a natural comparison. This helps a reader judge whether a stray field matters to a sensitive instrument, since the Earth field is roughly 0.5 Oe.

Reading old specifications

Older material cards and military specifications often give permeability tests at a field expressed in oersteds, for example a test field of 0.4 Oe or 1 Oe. Converting such a field to A/cm tells you what a modern A/m-based test setup must produce. A test field of 1 Oe is 0.7958 A/cm, or 79.58 A/m. A 10 Oe field is 7.958 A/cm, or 795.8 A/m. When you rewrite a procedure in SI, keep the original value in parentheses so that anyone checking against the old document can match the two. This is also a courtesy to readers, since it lets them see that the two forms of the specification describe the same test condition.

Coil fields in both units

A solenoid of 100 turns, 0.5 A and 5 cm length produces a field H = N × I / l = 50 ampere-turns over 0.05 m, or 1,000 A/m. That is 10 A/cm, which this page converts to 12.566 Oe. A coil with 300 turns, 2 A and 12 cm gives 5,000 A/m, or 50 A/cm, which is about 62.83 Oe. Teaching labs often compute H in SI units and compare with a gaussmeter calibrated in gauss, relying on the numerical match between oersted and gauss in air. The conversion here gives the oersted value that the gaussmeter should read, within the calibration accuracy of the probe. Compare any such coil estimate with a probe reading in the middle of the coil, where the long-solenoid formula applies best.

Rounding the 4π/10 factor for oersteds

The factor 1.25663706144 is the value 4π / 10 rounded to eleven decimal places, and the result is shown to the full precision of the calculation. In practice, two or three significant figures are as much as magnetic measurements support, so quote 12.6 Oe or 12.57 Oe for the default. Do not use 1.26 as a conversion factor for large fields, since the rounding error is about 0.3 percent, which is already larger than the uncertainty of a good probe. Using the page value avoids accumulating rounding when you convert a chain of measurements. As a check on the factor itself, 4 × 3.14159265 / 10 gives 1.2566371, which agrees with the page value to seven digits.

Gauss and tesla not covered

The page converts the unit of a fieldstrength you already know. It does not calculate a field from a current, convert to gauss or tesla, or evaluate whether a field is safe or suitable for a device. As the assumptions state, it does not calculate installation limits, equipment ratings, protection, material response or compliance. For work with strong magnets or coils, follow the equipment documentation and the applicable standards, and treat a converted figure as a restatement of the original reading.