Old CGS data meets SI coil specifications
Magnetic field strength H has two common unit families. Older US literature, many magnet data sheets and some lab instruments use the oersted from the CGS system, while SI-based specifications use amperes per meter, and some European inspection and measurement practice states field strength in amperes per centimeter. A person who reads a magnet supplier sheet in oersteds and a test procedure in A/cm needs a reliable conversion. This page multiplies oersteds by about 0.7958 to give A/cm. It is written for technicians, students and engineers who set coil currents, read instrument ranges or compare test conditions from documents that were written under different unit habits.
The factor 1,000/(4π)
The oersted is defined in the CGS electromagnetic system so that 1 Oe equals 1,000/(4π) A/m, which is 79.5774715459 A/m. Since a meter holds 100 centimeters, the same number divided by 100 gives 0.795774715459 A/cm. The factor contains π, so its decimal form never ends, and the page stores it with finite precision. NIST SP 811 lists the oersted and its SI equivalent. In practice, remember that one oersted is a little less than 0.8 A/cm, and one A/cm is about 1.2566 Oe. If the page returns a number larger than your input, check the From and To menus, because oersteds to A/cm always gives the smaller number.
Ten oersteds in A/cm
The default of 10 Oe returns 7.957747154594768 A/cm. For reporting you would write 7.96 A/cm, keeping the digits your source supports. The result follows from the factor: 10 × 0.795774715459 is 7.95774715459. Other values scale the same way. A field of 5 Oe is 3.978874 A/cm, 25 Oe is 19.89437 A/cm and 1,000 Oe is 795.7747 A/cm. The number of digits shown is far more than any field probe can deliver, so round before you write the value in a procedure. Keep the unit with the number, since an A/cm figure copied without its unit can be mistaken for A/m, which is 100 times larger.
A solenoid with 20 turns per centimeter
The field inside a long solenoid is the number of turns per unit length times the current. A winding with 20 turns per centimeter carrying 2 A gives 20 × 2 = 40 A/cm along its axis, and the page converts the other way to show that 40 A/cm is 50.26548 Oe. If a procedure asks for 25 Oe, you need 19.89437 A/cm, or about 1 A through the same winding. The idealized formula holds for a coil that is long compared with its diameter, and real coils have end effects and heating. Measure the field with a calibrated probe when the value matters, and use the page to keep the units consistent.
Inspection settings and procedure sheets
Magnetic particle inspection and some eddy current and permeability tests state a required field strength in the procedure. The unit depends on the standard or the customer. A lab that owns a gaussmeter and a probe may read oersteds or gauss in air, whereas the procedure lists a minimum in A/cm or kA/m. Converting the specification into the unit of your instrument avoids a conversion at the bench. Check the standard that governs your work for the required value and the position at which it applies, because the field varies across a part. The converter does not know a standard, and it returns only the unit equivalent of the number you provide.
From A/cm back to oersteds
Set amperes per centimeter as the source and oersteds as the target to convert a coil or procedure value into the unit of a data sheet. A field of 100 A/cm is 125.6637 Oe, 40 A/cm is 50.26548 Oe and 1 A/cm is 1.256637 Oe. The page divides by the same factor, 0.795774715459, so the answer is always larger than the A/cm number. This direction is useful for reading older papers and for setting a device that has a dial in oersteds. When you round, keep one digit more than your measurement supports and drop it at the end, so that repeated conversion does not accumulate small differences.
Field strength H versus flux density B
Oersteds describe H, the field strength, and gauss describes B, the flux density. In air or vacuum the two numbers are equal in the CGS system, so 10 Oe corresponds to 10 G, which is 1 mT. In a magnetic material, B also depends on the permeability, and the relation is not a fixed factor. The page converts only H in oersteds to H in A/cm and does not produce a value in tesla. When a data sheet gives B in gauss and a procedure gives H in A/cm, you need the material property, or a measurement in air, before the two can be connected. Mixing H and B is a frequent source of confusion in magnetics, and it shows up in lab reports and forum questions alike. If a source says only gauss or tesla, treat it as flux density and look for a separate H value before using this page.
Rounding and the reverse check
The factor has twelve digits on this page, and your field value has far fewer. Round the answer to the precision of the input: a field of 25 Oe measured to two digits becomes 19.9 A/cm, not 19.89437 A/cm. To check a result, convert it back. Entering 19.89437 A/cm with oersteds as the target returns 25 Oe within rounding. A small difference after a round trip is normal, because the stored factor has finite precision. For a procedure document, write both values with their units, for example 25 Oe (19.9 A/cm), so a reader in either unit system can follow the step.