Matching a magnet datasheet to your own measurements
Magnetic materials are described in two families of units that seldom share a page. European and Japanese magnet catalogs usually print coercivity and demagnetizing limits in kA/m, older US sheets and many textbooks use oersteds, and bench instruments or coil calculators often report A/m or A/cm. This converter moves a number between those four labels so you can compare one supplier with another, or compare a catalog value with a reading from your own setup. Pick From to match the label you are reading and To to match the document you are filling in. The default entry converts 10 A/m to kA/m and returns 0.01, because one kiloampere per meter is 1,000 A/m. Everything else on the page follows from the same pattern.
The four factors, stated against A/m
Amperes per meter is the SI unit of H. The kiloampere per meter is 1,000 A/m by the SI prefix definition, and one ampere per centimeter is 100 A/m because a meter holds 100 centimeters. The oersted comes from the CGS electromagnetic system, and NIST SP 811 gives it as 1,000/(4π) A/m, which is about 79.57747 A/m. The page stores the oersted factor with finite precision, so very long results end in rounding noise beyond the ninth or tenth digit, far below any measurement you would make. To convert between two non-SI units, such as A/cm and oersteds, the page goes through A/m: 1 A/cm is 100 A/m, and 100 divided by 79.57747 is about 1.2566 Oe.
Turns and current in a long coil
A common bench task is finding H inside a long solenoid. The textbook relation H = N × I / l, with N turns, current I in amperes and coil length l in meters, gives amperes per meter directly. Take 500 turns on a 0.25 m coil carrying 2 A. That is 500 / 0.25 = 2,000 turns per meter, and 2,000 × 2 = 4,000 A/m. Entering 4,000 A/m with the target set to kA/m returns 4. If a lab sheet asks for the answer in A/cm instead, the same field is 40 A/cm. The relation assumes a coil much longer than its diameter and ignores end effects, so it suits a teaching setup better than a short, fat winding.
Oersteds in older documents
The oersted is still printed on vintage handbooks, some hard-magnet comparison charts and loudspeaker magnet literature. Converting 20 Oe gives about 1,591.55 A/m, or roughly 1.59 kA/m. In the other direction, 800 A/m is about 10.05 Oe. A small field helps with intuition. The Earth's field at the surface is of the order of a half oersted, and 0.5 Oe converts to about 39.79 A/m. That number describes H in air, where B in gauss and H in oersteds are numerically close. Inside a material the two quantities diverge, which is why the page converts H units only and never produces B.
Coercivity figures in kA/m and Oe
Permanent-magnet catalogs list coercivity, the opposing field needed to reduce magnetization or flux density to zero. Imagine a catalog entry of 1,200 kA/m for a rare-earth grade, while the application note you are following wants oersteds. Choose kiloamperes per meter as the source and oersteds as the target. The result is about 15,079.64 Oe. Going the other way, a ferrite sheet quoted at 3,000 Oe converts to roughly 238.73 kA/m. Both figures are illustrative inputs for the exercise, not values for any specific product. Always compare the same definition on both sides, since catalogs separate the field that zeroes B from the field that zeroes magnetization, and this page converts the unit without telling you which one a number is.
H is not B
The tesla and gauss measure magnetic flux density B, while this page covers the field strength H. In vacuum they are linked by B = μ0 × H, and in a magnetic material the permeability of that material enters the relation. A gaussmeter reading cannot be fed into this converter, and a value in A/m cannot become tesla without knowing the medium. If your datasheet shows a curve with H on one axis and B on the other, convert each axis with its own tool. The magnetic flux density converter on this site handles tesla and gauss, and the page you are on handles only H units.
Choosing between A/m and A/cm in practice
Different trades settle on different scales. Core-material curves for electrical steel and ferrites tend to run in A/m or A/cm, because working fields of a few hundred to a few thousand A/m are common there. Hard-magnet work reaches into kA/m. A reading of 5 kA/m is 5,000 A/m or 50 A/cm, and writing it in A/cm keeps the numerals short on a hand-drawn graph. Using one unit across a whole report prevents transcription mistakes, so convert once at the start and carry that unit through your tables instead of mixing labels line by line.
Converting a whole column of readings
Lab reports and datasheet comparisons often need an entire column converted, not one number. Because the relationship is linear, three anchor points are enough to audit a table. A value of 10 Oe should land at about 795.77 A/m, 50 Oe at about 3,978.87 A/m and 100 Oe at about 7,957.75 A/m. Each row is the oersted value times 79.57747, so the ratio between any two rows must match the ratio of the original readings. If one row breaks the pattern, it was mistyped or came from a different source. Convert the first and last rows with this page, check the middle against the anchors, and keep the unit in the column heading instead of in every cell. The same audit works for kA/m and A/cm columns, where the anchors are 1,000 and 100.
Precision and what the result does not tell you
The converter reproduces unit relationships and nothing else. It does not model saturation, temperature effects, demagnetization, material response or the safe working field of a part, and it says nothing about equipment ratings or compliance with a standard. The oersted result carries the precision of the stored factor, so rounding a final figure to four significant digits is more than enough for a datasheet comparison. If two sources disagree after conversion, check whether one of them reports field at the magnet surface and the other inside the material, since no unit conversion can reconcile those.