Resistance of a layer, per unit area
Thermal insulance is the temperature difference across a layer needed to drive a unit of heat flux through it. In SI it is the square meter kelvin per watt, m²·K/W, also called RSI in building documents. For a flat layer, it equals thickness divided by thermal conductivity, R = d/k, and for a sequence of layers the values add. A 100 mm layer of mineral wool with k = 0.04 W/(m·K) has R = 0.1 / 0.04 = 2.5 m²·K/W. Its reciprocal is the U-value, 1/R, in W/(m²·K), which here is 0.4. A larger insulance means less heat flows for the same temperature difference.
The clo
The clo is a unit used for clothing insulation. It was introduced by Gagge and colleagues in 1941, and 1 clo equals 0.155 m²·K/W. A typical business suit with underwear is about 1 clo, and a light summer outfit about 0.5. Heavy winter clothing for cold weather reaches 3 or 4 clo. Going the other way, 1 m²·K/W is about 6.4516 clo. A garment with 0.31 m²·K/W is 2 clo. The converter on this site handles these two units. The clo is designed for the whole clothed body with a layer of air, so it does not equal the sum of the fabric alone. Added garments increase the total by less than their individual values, because the air gaps between layers contribute a share.
The United States R-value
American building labels use R-values in ft²·°F·h/BTU. NIST SP 811 gives the conversion as 1 ft²·°F·h/BTU(IT) = 0.1761 m²·K/W, so an R-value is multiplied by 0.1761 to get RSI, and RSI is multiplied by 5.678 to get R. R-13 corresponds to 2.29 m²·K/W, R-19 to 3.35, and R-38 to 6.69. A wall rated RSI 3.5 is R-19.9. The same unit symbol R appears in both systems, and an R-value of 3.5 would be a very different quantity from RSI 3.5, a factor of 5.7. This site converts between m²·K/W and clo only, so the R-value factor here is background.
Adding layers and air films
A wall assembly is the sum of its layers, plus air films on both surfaces. Interior and exterior film resistances are commonly taken as about 0.13 and 0.04 m²·K/W in standards. A wall of 12.5 mm plasterboard with R = 0.06, 100 mm of mineral wool at 2.5, and 100 mm of brick at about 0.12, plus the films, totals 0.06 + 2.5 + 0.12 + 0.13 + 0.04 = 2.85 m²·K/W. The U-value is then 0.35 W/(m²·K). Layer values are illustrative, and a design calculation uses the product data and the method of the local building standard.
Heat loss from the U-value
Given R, heat flow through an area follows from Q = A ΔT / R. A 20 m² wall with R = 2.85 m²·K/W and a 20 K temperature difference loses 20 × 20 / 2.85 = 140 W. Doubling the insulation to 5.7 halves the loss to 70 W. Insulating beyond a certain level gives diminishing returns, because the saved watts fall as 1/R. A single pane of glass at about 0.17 m²·K/W loses 2350 W through 20 m² at the same difference, which shows why windows dominate losses in many houses. The page covers the unit conversion, and heat-loss calculations need other inputs.
Thermal conductivity and insulance
Conductivity k, in W/(m·K), describes a material, while insulance describes a particular thickness of it. Doubling the thickness doubles R but leaves k alone. Typical k values are about 0.025 for polyurethane foam, 0.035 to 0.045 for mineral wool, around 0.12 for softwood across the grain, 1.0 for brick and 1.7 for concrete. A table of R per inch or per meter is a convenience that assumes uniform behavior. Moving from k to R requires a thickness, which a pure unit conversion of insulance does not have.
Clothing and comfort
Clothing insulation figures appear in comfort standards such as ISO 7730 and ASHRAE 55, where 1 clo suits an indoor winter outfit and a thick coat can add 1 to 2 clo. The relation to heat loss is rough: a seated person producing about 58 W/m² of skin surface in light indoor clothing is usually comfortable in a room near 21 to 23 degrees Celsius. These standards use the metabolic unit met, with 1 met equal to 58.15 W/m². The numbers apply to a standard body with air around it. The converter supports only the exchange between clo and m²·K/W and gives no comfort rating.
How insulance is measured
Laboratories measure the insulance of flat samples with a guarded hot plate, described in ISO 8302 and ASTM C177, or with a heat flow meter apparatus, described in ISO 8301 and ASTM C518. In both, a sample sits between a hot and a cold plate, and the instrument records the heat flux and the temperature difference. Dividing the difference by the flux gives R directly in m²·K/W. A sample that shows 2 K across it with a flux of 0.8 W/m² has R = 2.5 m²·K/W. Test reports usually give the mean test temperature, because insulance changes with it, and a label value is the result for those stated conditions. Clothing is measured differently, with heated manikins, which is how clo values are assigned to garments.
Common mistakes
Several errors recur. Adding conductivities instead of insulances, or multiplying R by thickness when R already includes it. Treating RSI and R as the same number. Forgetting the factor between clo and m²·K/W, so a 0.155 value gets read as 0.155 clo. Applying a labeled R-value for a compressed batt, since insulation squeezed below its rated thickness loses insulance. And ignoring thermal bridges, where studs and fasteners carry heat around the insulation, which lowers whole-wall performance below the sum of the layer values. The unit conversion is exact, and the inputs are the part that needs judgment. A fixed rounding rule helps: RSI to two decimals and R-values to one decimal is enough for specifications, and carrying more digits implies precision that the product tests do not support. A quick plausibility check is that a single-layer clothing value above 4 clo or a wall below 0.3 m²·K/W should prompt a second look at the unit.
Precision and checking
- Retain the area and temperature-interval factors.
- A definition comparison does not establish a product or installation rating.
Reference numbers are displayed with up to twelve significant digits. That display does not add precision to a rounded measurement. Keep source and target quantities compatible, confirm symbol case and regional conventions, and round the final result to precision justified by the input. Factors involving π or repeating fractions use finite numerical precision.
Choose a unit definition
Square meter kelvins per watt (m²·K/W)
Definition, reference values and linked conversions.
Clo (clo)
Definition, reference values and linked conversions.
Use a working converter
- Thermal insulance (R-value) converter
- Square meter kelvins per watt to Clo converter
- Clo to Square meter kelvins per watt converter
Source and verification scope
The reference values and examples use the versioned unit definitions shared with the linked converters. Source dates identify the stated access or verification scope. A reverse calculation checks arithmetic and direction, but it does not independently verify a definition. Computandum is independent of the cited organizations, and the citations do not imply endorsement of this guide or a real application.