Thermal comfort work in two unit systems

The clo is a practical unit of clothing insulation used in thermal comfort research and standards such as ASHRAE 55 and ISO 7730, which relate clothing to indoor temperature. Heat transfer calculations, on the other hand, work in square meter kelvins per watt, the SI unit of area-normalized thermal resistance. Someone estimating comfort for an office, a cold-weather garment or a climate chamber test often needs both. A garment rated at 1.5 clo has to be entered as 0.2325 m²·K/W in a heat balance. This page does the step in either direction and shows the values side by side for comparison with specification tables.

The definition of one clo

One clo equals 0.155 m²·K/W, a value given in NIST SP 811 among the non-SI units of thermal insulance. The unit was proposed in the early 1940s by Gagge, Burton and Bazett and was intended to describe the insulation of a typical business suit that lets a resting person stay comfortable at roughly room temperature. The formula on the page is m²·K/W = clo × 0.155. The default 10 clo gives 1.55 m²·K/W. The factor is a defined constant, so the conversion adds no error, and any number you read from the output is as exact as the number you typed.

Typical garments and ensembles

Everyday values give a sense of scale. Light summer clothing is about 0.5 clo, which is 0.0775 m²·K/W. A typical indoor winter outfit with long sleeves and trousers is near 1.0 clo, or 0.155 m²·K/W. Heavy winter clothing for outdoor work may reach about 2 to 3 clo, and polar expedition gear several clo more, so 4 clo equals 0.62 m²·K/W. The table values vary by source and by how the air layer around the body is counted, so use the figure published in the standard or paper you rely on. The converter does not choose garments or sum them, it only restates the number in SI units. Standards such as ISO 9920 and ASHRAE 55 publish the garment tables, and a person rarely wears an ensemble that matches one table row, so the stated clo is an estimate for a typical wearer. Keep that uncertainty in mind when two sources give 0.9 and 1.1 clo for similar clothing.

Clo is not building R-value

The word insulation invites a comparison with building R-values, but the two apply to different problems. Clothing insulation here includes the air layer on the body and is expressed per unit of body surface area, while an RSI value describes a wall or roof assembly. A wall with RSI 3.5 m²·K/W is equivalent to 22.6 clo, a number far beyond any garment, which shows why clo is reserved for people. To reach the US building R-value in ft²·°F·h/Btu, multiply RSI by 5.678, so 1 clo is about 0.88 in those units. Mixing building and clothing values in one calculation is a common source of misleading comparisons.

Reverse direction: from m²·K/W to clo

Swap the menus to convert area-normalized thermal resistance into clo by dividing by 0.155. A resistance of 0.31 m²·K/W corresponds to exactly 2 clo, and 0.0775 m²·K/W to 0.5 clo. This is helpful when a thermal manikin test reports garment insulation in SI units and a comfort model, such as the ones in ASHRAE 55, expects clo. A result larger than the input in the reverse direction is normal because the clo is a smaller number per unit of insulation than the SI value is large. If you see the opposite, check that the From and To menus are not swapped.

What the 0.155 factor represents

The unit combines heat flow and area. A thermal resistance of 1 m²·K/W means that a temperature difference of 1 K across 1 m² drives 1 W through the layer. A clo, at 0.155, therefore passes about 6.45 W per square meter for each kelvin of difference between skin and the outside of the clothing. At a 10 K difference that is roughly 64.5 W/m², a rate that can be compared with a resting person metabolic heat output of about 58 W/m², a figure often used in comfort standards. This is only a reading aid for the factor. The page does not perform heat balance calculations.

Rounding and measurement uncertainty

Garment insulation measured on a thermal manikin or taken from a table has uncertainty of several percent, and the standards give ranges. A table might list a sweater at 0.28 clo, but a different weave or fit could be 0.25 or 0.32. Converting 0.28 clo to 0.0434 m²·K/W is exact arithmetic on an approximate input. Keep two or three significant digits in the output and avoid showing more than the source supports. When adding garments, treat a plain sum of clo values as an approximation, since layers trap air differently and standards give their own procedures for ensembles. The same caution applies to the converted figure, which is only as reliable as the clo value it came from, so carry the source and its stated range along with the number.

Related scales and limits

Other regions use other units for textile or bedding insulation, and the one most often discussed beside clo is the tog. This converter covers only clo and m²·K/W, and it does not confirm any other textile unit. It also does not account for wind, wetness, activity level, humidity or posture, all of which change the effective insulation of clothing in the real world. The result restates a clothing insulation value in SI units. Use a recognized comfort standard and the maker documentation of a garment or test method for any decision about protection against cold or heat.

Feeding a comfort model with SI insulation

Thermal comfort programs that implement the predicted mean vote method of Fanger take clothing insulation as an input, and some versions expect SI units rather than clo. An office worker in 0.7 clo of clothing enters 0.1085 m²·K/W, and a person in 1.0 clo enters 0.155 m²·K/W. Typing 0.7 where 0.1085 is expected makes the clothing nearly seven times too insulating, and the model will predict that everyone is too warm. The conversion step is therefore best done once, with the result written beside the original number in the input record. Sensitivity checks then use rounded values around the converted figure, such as 0.10 and 0.12 m²·K/W.