Square meter kelvins per watt (m²·K/W): thermal insulance unit guide

m²·K/W is the reference for thermal insulance.

Measurement basis

The area factor distinguishes insulance from K/W thermal resistance.

Definition conventions

The clo factor follows the cited NIST conversion reference. The source notes list a dimensional expression of 0.1 m² K/W for tog, but that definition still needs additional primary-source confirmation and is unavailable in these converters.

Conversion method

Keep m²·K/W unchanged; use the supported insulance factor for another target.

Reference equivalent of m²·K/W

1 m²·K/W = approximately 1 m²·K/W.

Recorded scale factors: 1 for m²·K/W; 1 for m²·K/W.

Worked example

Known input: 10 m²·K/W. Reference equivalent: 10 m²·K/W. The return conversion gives approximately 10 m²·K/W.

The example retains the heat-transfer area factor.

Common reference values

Input (m²·K/W)Reference equivalent (m²·K/W)
11
55
1010
2525
5050
100100

Compare one m²·K/W with other units

Target unitEquivalent of 1 m²·K/WDefinition guide
Clo (clo)6.45161290323Read definition

Insulation per square meter of wall

The square meter kelvin per watt, written m²·K/W, is the SI unit of thermal insulance, the quantity usually called R-value in building work. It is a temperature difference divided by a heat flux density: a layer with an insulance of 1 m²·K/W holds a difference of 1 K when 1 W of heat passes through each square meter. Because the area is in the unit, the figure describes a material layer or assembly regardless of its size. Thermal resistance in K/W belongs to a whole object of a given size, which is a separate quantity. Building standards such as ISO 6946 give layer values for walls and roofs in m²·K/W.

Adding layers in series

For a flat layer of thickness d and thermal conductivity λ in W/(m·K), the insulance is d divided by λ. Mineral wool 100 mm thick with λ of 0.035 gives 0.1 / 0.035 = 2.857 m²·K/W. Layers in series simply add. Add 12.5 mm of plasterboard at λ of 0.25, which is 0.05, plus the surface films that ISO 6946 sets at 0.13 inside and 0.04 outside for horizontal heat flow, and the total is 3.077. The U-value is the reciprocal, 1 / 3.077 = 0.325 W/(m²·K). The numbers are illustrative, since real products list their own conductivity on a declaration of performance.

The clo and its origin

The clo measures clothing insulation, and one clo equals 0.155 m²·K/W. It was proposed by A. P. Gagge, A. C. Burton and H. C. Bazett in 1941 as a practical unit for the heat exchange of a person with the surroundings, scaled so that 1 clo is roughly what a sedentary person in light indoor wear needs for comfort. The site factor from m²·K/W to clo is 6.45161290323, the reverse of dividing by 0.155. An insulance of 0.5 m²·K/W is 3.226 clo, and a clothing ensemble of 1.5 clo is 0.2325 m²·K/W. The tools are Square meter kelvins per watt to Clo converter, Clo to Square meter kelvins per watt converter and the Thermal insulance (R-value) converter.

US R-values and the metric figure

US and Canadian labels give R in ft²·°F·h/Btu. One such unit is about 0.1761 m²·K/W, so an R-13 batt corresponds to 2.29 m²·K/W, R-19 to 3.35 and R-38 to 6.69. Conversely, 1 m²·K/W is about 5.678 US R. Canadian metric labels write the same quantity as RSI, which equals the SI value. The two site converters here cover m²·K/W and clo only, so US R-values need the 0.1761 factor applied by hand. The rounding matters when you compare a label to a code requirement: a requirement of R-20 is 3.52 m²·K/W, and a product marked 3.5 would fall slightly short.

Typical values in practice

A single pane of glass has an insulance near 0.17 m²·K/W, a U-value of about 5.8. Double glazing with a low-emissivity coating and gas fill reaches roughly 0.7 to 0.9. A 100 mm layer of expanded polystyrene with λ of 0.038 gives 2.63, polyisocyanurate board at 0.022 gives 4.55, and 200 mm of dense concrete at λ of 1.7 gives only 0.12. A wall that meets the Passivhaus guideline of a U-value of 0.15 corresponds to a total of 6.67. These are representative figures for common materials, so a specific product may differ. They show why a thin insulating layer outranks a thick masonry one. A 300 mm loft layer of mineral wool with λ of 0.04 gives 7.5 m²·K/W, which is about R-42.6 in US units.

Turning insulance into heat loss

Heat loss through a flat element is U × A × ΔT. For 40 m² of wall with U of 0.325 and an indoor to outdoor difference of 20 K, the loss is 0.325 × 40 × 20 = 260 W. Doubling the insulance halves that loss, but the gains shrink. Raising total R from 3 to 6 lowers U from 0.333 to 0.167 and saves 3.3 W per square meter at 20 K. Raising it from 6 to 9 lowers U to 0.111 and saves only another 1.1 W. This is why cost-benefit studies of insulation thickness flatten out, and why air tightness and windows often decide the remaining loss.

Studs, bridges and wet insulation

Insulation values come from laboratory tests on dry samples, with heat flow meter or guarded hot plate methods under standards such as ISO 8301 and ASTM C518. In a wall the framing is a thermal bridge. If studs fill 15 percent of the area with a layer of 0.74 m²·K/W (89 mm of wood at λ of 0.12) beside a cavity of 2.29, the area-weighted layer is 1 / (0.85/2.29 + 0.15/0.74) = 1.74 m²·K/W, well below the 2.29 printed on the batt. Moisture, compression and aging can lower values further. Nominal figures give a starting point, and a whole-wall calculation with the right standard gives the design value.

Clothing, metabolism and comfort models

Comfort standards such as ISO 7730 and ASHRAE 55 use clo for clothing and met for metabolic rate. One met is 58.15 W per square meter of body surface, so an adult with 1.8 m² of skin at rest gives off about 105 W. Typical ensembles run from near 0.5 clo for summer indoor wear to about 1 clo for a business suit with underwear and over 3 clo for cold-weather outerwear. These are catalog values that vary by garment fit and fabric. A clo value says nothing about wind or damp, so a rating from still-air tests overstates warmth in a gale.

Notation and what is not covered

The unit is written m²·K/W, m²K/W or K·m²/W, and a plain temperature difference of 1 K equals 1 °C. It is easy to confuse with thermal conductivity in W/(m·K), the U-value in W/(m²·K), and thermal resistance in K/W. The tog, used for duvet ratings, is not converted on this site because its definition still awaits primary-source confirmation, so treat any tog figure as outside these converters. A converted insulance describes a single layer or assembly in steady conditions and does not establish that a building meets a code, which depends on climate zone, rules and the full construction. When conductivity is in W/(m·K) and thickness in millimeters, convert the thickness to meters first, since 100 mm and 0.1 m differ by a factor of 1,000 in the quotient.

Precision and checking

  • Keep source insulance precision.
  • Retain conditions and area context.

Reference numbers are displayed with up to twelve significant digits. That display does not add precision to a rounded measurement. Keep source and target quantities compatible, confirm symbol case and regional conventions, and round the final result to precision justified by the input. Factors involving π or repeating fractions use finite numerical precision.

Use a working converter

Source and verification scope

The reference values and examples use the versioned unit definitions shared with the linked converters. Source dates identify the stated access or verification scope. A reverse calculation checks arithmetic and direction, but it does not independently verify a definition. Computandum is independent of the cited organizations, and the citations do not imply endorsement of this guide or a real application.