Clothing insulation in comfort standards

Thermal comfort standards such as ASHRAE 55 and ISO 7730 describe what people wear in clo, a unit of insulation per area. A heat-transfer calculation or a manikin test reports the same property in square meter kelvins per watt. Anyone who moves between a building physics file in SI and a comfort worksheet in clo needs the conversion. This page divides by 0.155 and returns clo, so a measured thermal resistance can be set against the clothing values in a comfort model. It handles the conversion of insulation values only, and does not compute comfort, heat loss or the temperature a person will feel. Those results need a model with air temperature, humidity, air speed, radiant temperature and activity level as well as the clothing value.

One clo is 0.155 m²·K/W

The clo is defined as 0.155 m²·K/W, a figure used in the standards and stored by this page. The conversion to clo is a division by 0.155, which is the same as multiplying by about 6.4516. The default of 10 m²·K/W becomes 64.5161290323 clo. That number is far larger than any clothing ensemble, since a heavy winter outfit is about 2 clo, so the default reads as an abstract demonstration of the factor. A wall or a roof has resistances in the several m²·K/W range, which is why clo is not usually used for buildings. The unit is area-normalized: it describes resistance across a surface, and it is not a measure of thermal resistance in K/W for a whole object.

Typical clothing values

Illustrative values from comfort practice are about 0.5 clo for light summer clothing and about 1.0 clo for typical indoor winter clothing. In SI terms, 0.5 clo is 0.0775 m²·K/W and 1.0 clo is 0.155 m²·K/W. A set of heavy outdoor clothing at 1.5 clo is 0.2325 m²·K/W. Enter any of these in the reverse direction to compare. The values explain why people feel comfortable in a room several degrees cooler when wearing a sweater: adding a sweater raises the insulation of the whole ensemble by a few tenths of a clo, which is equivalent to a change in the comfortable air temperature of a degree or two, according to comfort models.

A manikin result of 0.31 m²·K/W

A thermal manikin test returns the insulation of a garment ensemble in m²·K/W. Suppose a winter parka and layers measure 0.31 m²·K/W. The page converts that to 2 clo, which is near the heavy end of what everyday outdoor clothing delivers. If a spec sheet for work wear lists 0.31 m²·K/W, a safety officer can place it on the same clo scale used in cold-environment guidance. Garment datasheets usually give either intrinsic insulation, the clothing alone, or total insulation including the air layer around the body. The factor is the same for both, but the two figures answer different questions, so check which one the source reports.

Walls and roofs on the clo scale

Building insulation is usually described in R-values. In SI, an R-value, or RSI, is also in m²·K/W, and one m²·K/W equals about 5.68 in US R-value units. A wall with 3.5 m²·K/W converts to about 22.58 clo, which shows how different the scale is from clothing. Nobody specifies a wall in clo, and the figure is presented only to show the relation. For a building, use the RSI or the US R-value directly. For people, clo is the common term. The unit conversion does not depend on the application, and the same division by 0.155 applies whether the surface is a coat or a ceiling.

Intrinsic and total insulation

Standards separate the intrinsic insulation of clothing from the total insulation that includes the boundary air layer. The first describes the garments, and the second what a person experiences. Both are expressed in m²·K/W or clo, and this page converts either with the same factor, since the choice between them changes the meaning of the number and leaves the unit relation alone. Mixing them up affects results more than any rounding. A figure of 0.155 m²·K/W for the clothing alone is 1 clo, but the total including air might read higher, depending on air movement. Before you use a converted value in a comfort model, check which type the model expects, and say which one you used in the report.

Bedding and other thermal ratings

This converter has only two units, m²·K/W and clo. Other thermal-resistance labels exist, for example on bedding in some countries, but they are not included here, and the page does not convert them. Insulation ratings for sleeping bags, jackets and duvets come from different test methods, and a conversion between unlike tests is not a pure unit change. If your label lists neither m²·K/W nor clo, read the manufacturer or standard documentation to see how the rating is defined before you try to relate it to the numbers here.

Precision and reverse checks

The reverse conversion multiplies clo by 0.155. As a check, 2 clo returns 0.31 m²·K/W. Because 0.155 is a defined figure, the conversion is exact apart from the 12-digit display, and a rounded answer returned to the first unit can differ in a distant decimal. Clothing insulation measurements are only good to a few percent, so quote two or three significant digits, and cite the test standard if the figure came from a manikin laboratory. If you build a comfort model that takes clo as an input, check whether it wants a single garment, a whole ensemble or an ensemble with chair effects included, because adding values from different sources can double count.

Layering and ensemble values

Garment tables list the insulation of individual items in clo. A thin base layer around 0.2 clo is 0.031 m²·K/W, a sweater near 0.3 clo is 0.0465 m²·K/W, and each of these can be converted with the factor of 0.155. Adding clo values for items worn together gives only an approximation of the ensemble, because the standards apply their own corrections for trapped air and body coverage. Use the standard formulas when the result matters, and use this page to put the garment values into the unit your calculation expects. A designer comparing work-wear options for a cold store can then see how much SI insulation each additional layer contributes.