Clothing tables use clo, building tables use m²·K/W
Thermal comfort standards describe what people wear in clo. A typical indoor winter outfit of underwear, shirt, trousers and a light jacket is rated near 1 clo, and light summer clothing is closer to 0.5. Building envelope data, on the other hand, is given as thermal resistance per unit area in m²·K/W, called RSI in some countries. Someone who wants to compare a coat with a wall layer, or who builds a comfort model that takes clothing resistance in SI, needs a conversion between the two. This page offers exactly that pair. It divides a value in m²·K/W by 0.155 for clo and multiplies a clo value by 0.155 for the reverse. Tog is not offered here because its definition has not been confirmed against a primary source.
The definition behind 0.155
The clo was set so that one unit equals 0.155 m²·K/W, a value NIST SP 811 lists among its conversion factors. The stored factor is therefore 1 / 0.155, or about 6.45161290323 clo per m²·K/W, and the formula on the page is clo = m²·K/W × 6.45161290323. Because the definition is a round number in SI, the conversion carries no measured uncertainty. The page shows up to twelve significant digits, which is far more than any clothing measurement supports. One practical consequence is that 0.155 m²·K/W gives 1 clo, 0.31 gives 2 clo and 0.0775 gives 0.5 clo, so those three quick checks help confirm that you picked the direction you intended.
What 10 m²·K/W looks like in clo
The page opens with 10 m²·K/W and returns about 64.5161 clo. That value is not clothing. It resembles a very heavily insulated roof or wall, roughly R-57 in US units, so the default shows the arithmetic and says little about what someone wears. For an everyday scale, a wall rated at 3.5 m²·K/W is 22.58 clo, which would be an absurd outfit and shows why the clo is reserved for textiles and garment systems. Switching the source to clo and entering 1 gives 0.155 m²·K/W, so a full set of indoor clothing resists heat flow about as much as 6 millimeters of mineral wool, using a conductivity near 0.04 W/(m·K) as an illustrative figure.
From clo to heat flow through clothing
Thermal resistance per area links a temperature difference to a heat flux: flux in W/m² equals the temperature difference divided by the resistance. As an illustration, with a 10 K difference across a layer of 1 clo, the flux is 10 / 0.155 = 64.5 W/m². An adult body surface of about 1.8 m² would then lose roughly 116 W across that layer alone. Doubling the clothing to 2 clo, which is 0.31 m²·K/W, halves the flux to 32.3 W/m². These numbers ignore the air film at the surface, convection and moisture, so they are a way to see how the unit works and not a model of a person. Comfort standards treat those effects separately.
Reading comfort-model inputs in SI
Thermal comfort tools such as those based on ASHRAE Standard 55 and ISO 7730 take clothing insulation in clo, and some research software wants m²·K/W. A researcher moving data between them can enter 0.7 clo and get 0.1085 m²·K/W, and enter 1.5 clo to get 0.2325 m²·K/W. Garment tables usually list the insulation of single items, and the total for an ensemble is not a plain sum, because trapped air layers and body coverage change the result. This page converts a total you already have, in either unit, and gives no estimate from a clothing list. If your source states the value including the surface air layer, keep that note with the number so that it is not added twice.
R-value in US units
In the United States, building R-values are written in ft²·°F·h/Btu, and one m²·K/W is about 5.678 of them. This converter does not offer that unit, but the relation helps place the numbers: 1 clo is 0.155 m²·K/W, or about 0.88 in US R-value terms. A wall labeled R-20 is close to 3.5 m²·K/W, and that is about 22.6 clo on this page. Because the US figure and the SI figure describe the same quantity per unit area, you can compare a wall and a garment only after both are on a per-area basis. Total resistance in K/W for a whole object is a different quantity and has its own converter.
A lab clo rating on a windy ridge
A clo value belongs to a garment or an ensemble measured under defined conditions, typically on a heated manikin in still air. Wind, wet clothing, compression of insulation under a backpack strap and body movement all lower the effective value. A parka rated at 3 clo in a lab may deliver far less on a windy ridge. The unit conversion cannot capture any of this. It only restates the number you give it, so a rating from a test report converts cleanly, while a casual guess about a coat does not become more precise by passing through this page.
Sleeping layers and bedding
Bedding and sleepwear can be placed on the same scale. A duvet plus pajamas adds up to a clothing-plus-bedding resistance that some sleep studies describe in clo, and values above 3 clo are typical of heavy bedding in a cool room. Suppose a sleeper under a quilt is described as having 0.62 m²·K/W of total insulation. Dividing by 0.155 gives 4 clo. The reverse is just as easy: a source quoting 2.5 clo for a blanket system is 0.3875 m²·K/W. The page returns these figures immediately, but the insulation of bedding changes with compression, so a rating measured on a flat sample will not equal the value under a sleeping person.
Recording R-values and clo together
The page does not choose clothing, size insulation or check a building against a code. It does not verify that a stated R-value is right for a climate, and it does not model moisture or air leakage. For building work, use the requirements and test reports that apply where you live, and for clothing in a cold environment, rely on guidance written for that activity. When you record a value in a report, write both the number and its unit, for example 0.31 m²·K/W (2 clo), so that a reader can check the conversion against the 0.155 definition.