MEASUREMENT & METHODS

Clo (clo): thermal insulance unit guide

clo is a supported thermal-insulance unit.

Measurement basis

The stored definition is 0.155 m²·K/W per clo.

Definition conventions

The clo factor follows the cited NIST conversion reference. The source notes list a dimensional expression of 0.1 m² K/W for tog, but that definition still needs additional primary-source confirmation and is unavailable in these converters.

Conversion method

Multiply clo by 0.155 for the thermal-insulance reference.

Reference equivalent of clo

1 clo = approximately 0.155 m²·K/W.

Recorded scale factors: 0.155 for clo; 1 for m²·K/W.

Worked example

Known input: 10 clo. Reference equivalent: 1.55 m²·K/W. The return conversion gives approximately 10 clo.

The calculation preserves insulance rather than estimating comfort.

Common reference values

Input (clo)Reference equivalent (m²·K/W)
10.155
50.775
101.55
253.875
507.75
10015.5

Compare one clo with other units

Target unitEquivalent of 1 cloDefinition guide
Square meter kelvins per watt (m²·K/W)0.155Read definition

A unit for what you wear

The clo is a unit of thermal insulance made for clothing. It describes how well a garment or an entire outfit resists the flow of heat from the skin to the surroundings. The converter on this site gives 1 clo = 0.155 m²·K/W, and in the other direction 1 m²·K/W = 6.4516 clo. The unit comes from 1941 work by A. P. Gagge, A. C. Burton and H. C. Bazett, who proposed a unit based on the insulation of a typical indoor business outfit. It is used in thermal comfort standards such as ASHRAE 55 and ISO 7730, and in clothing tables such as ISO 9920. The number lets building engineers and clothing designers speak about the same property without referring to a particular fabric.

The factor to square meter kelvins per watt

Thermal insulance in SI is area times temperature difference divided by heat flow, so it carries the unit m²·K/W. One clo equals 0.155 m²·K/W, which means a layer of 1 clo over 1 m² of skin lets 6.45 W flow for each kelvin of temperature difference. The original definition in older units was 0.18 °C·m²·h/kcal, and converting that with 1 kcal/h = 1.163 W gives about 0.155. A garment rated at 0.5 clo is 0.0775 m²·K/W, and 1.5 clo is 0.2325 m²·K/W. The same quantity is what building engineers call an R-value, though building R-values use different units and cover walls rather than people.

Typical clothing values

Published tables give approximate values. Standing naked in still air is 0 clo, though the air layer around the body adds a little. Shorts and a short-sleeve shirt come to about 0.3 to 0.5 clo, light summer office clothing close to 0.5 clo, a typical business suit with a shirt and tie about 1 clo, and a heavy winter outfit with a coat 2 clo or more. Polar clothing can reach 4 clo and higher. A rating of 1 clo therefore means about 0.155 m²·K/W, which in a clothing table stands for a typical indoor business ensemble. Converting the other levels, 0.5 clo is 0.0775 m²·K/W and 2 clo is 0.31 m²·K/W. These are illustrative averages from standards, since real garments depend on fit, fabric thickness, trapped air and movement, and wind or wetness reduces the value.

How a clo value changes comfort estimates

Comfort standards combine clothing insulation with activity level, air temperature, mean radiant temperature, air speed and humidity. A person at rest in an office, with an assumed activity of 1.2 met, who wears 0.5 clo feels comfortable at a warmer room temperature than the same person at 1.0 clo. A common rule of thumb in the standards is that an extra 0.1 clo offsets roughly 0.6 °C of operative temperature, though the exact relation depends on conditions. That is why summer dress codes that allow lighter clothing can allow a higher thermostat setting without discomfort. The clo number is only one input to such a calculation and does not by itself predict comfort.

Whole outfit versus single garments

Tables list single garments and entire ensembles. A summed estimate adds individual garment values with an adjustment, because layers do not add perfectly. ISO 9920 and ASHRAE 55 give the method: the ensemble value is usually a little less than the sum of the parts, since air gaps and compression change the total. A thin shirt of 0.15 clo plus trousers of 0.25 clo plus a sweater of 0.28 clo adds to 0.68 clo in a simple sum, and standards apply a regression to include underwear and shoes. Converted to SI, the simple sum of 0.68 clo is 0.1054 m²·K/W. Because the added garments are compared on a single numerical scale, a designer can see at a glance which layer contributes most. Sweaters and jackets usually outweigh shirts, and thick trapped-air layers outweigh thin dense fabric of the same weight.

The tog and the converter's scope

The tog is a related unit used for duvets and sleeping bags in Britain and in some other countries. A tog is defined as 0.1 m²·K/W, so 1 clo is about 1.55 tog. The converter on this site supports clo and square meter kelvins per watt but does not offer tog yet, pending additional primary-source confirmation. For other bedding or clothing labels, the conversion should therefore be done using the SI value as the bridge. A duvet of 10.5 tog would be 1.05 m²·K/W, which is 6.8 clo. Tog ratings come from a standardized test that includes surface air layers, and the clo ratings for clothing do not follow the same method, so a comparison between a duvet and a coat is only approximate.

R-values and the US building unit

US building products are labeled with R-values in ft²·°F·h/BTU. One m²·K/W equals about 5.678 of those units, which makes 1 clo about 0.88 in the American R-value system. A 6 inch fiberglass batt of R-19 is roughly 3.35 m²·K/W. That batt would be about 21.6 clo, a number that has little meaning for clothing, which shows why the unit family is attached to a context. The conversion between clo and R-value is only a unit change, not a statement about whether a wall performs like a coat. Clothing values include the layer of air at the surface and the movement of the wearer, while building values are for still, flat assemblies.

What a clo rating cannot tell you

A clo value is a measured or tabulated insulation for a standard condition, usually still air or very light air movement. In wind, insulation falls as moving air strips the boundary layer and forces air through the fabric. Moisture changes the value too, since wet insulation conducts heat far better. Body movement, such as walking, compresses and flushes the trapped air, reducing the effective value by perhaps 10 to 30 percent compared with standing. Standards therefore provide correction methods. A practical example: a jacket rated at 0.4 clo worn over a 1.0 clo ensemble adds roughly 0.062 m²·K/W of dry insulation before any correction for fit, and that extra layer is worth about 2.4 °C in the comfort rule of thumb quoted above. As a unit, the clo conserves one fact: it measures resistance to dry heat transfer per square meter of body surface. It does not measure warmth by feel, and it should not be applied to evaporative cooling, where humidity and vapor permeability control the outcome.

Precision and checking

  • Retain source insulance precision.
  • Keep the heat-transfer area factor.

Reference numbers are displayed with up to twelve significant digits. That display does not add precision to a rounded measurement. Keep source and target quantities compatible, confirm symbol case and regional conventions, and round the final result to precision justified by the input. Factors involving π or repeating fractions use finite numerical precision.

Use a working converter

Source and verification scope

The reference values and examples use the versioned unit definitions shared with the linked converters. Source dates identify the stated access or verification scope. A reverse calculation checks arithmetic and direction, but it does not independently verify a definition. Computandum is independent of the cited organizations, and the citations do not imply endorsement of this guide or a real application.

Sources

Read the calculation and sourcing methodology →