MEASUREMENT & METHODS

Square millimeters per second (mm²/s): thermal diffusivity unit guide

mm²/s expresses thermal diffusivity in this guide.

Measurement basis

The reference factor is 10^-6 m²/s.

Definition conventions

Preserve the thermal meaning when comparing values with the same-looking dimensions.

Conversion method

Multiply by 10^-6, using the squared milli-length scale.

Reference equivalent of mm²/s

1 mm²/s = approximately 0.000001 m²/s.

Recorded scale factors: 0.000001 for mm²/s; 1 for m²/s.

Worked example

Known input: 10 mm²/s. Reference equivalent: 0.00001 m²/s. The return conversion gives approximately 10 mm²/s.

The example keeps the thermal property context.

Common reference values

Input (mm²/s)Reference equivalent (m²/s)
10.000001
50.000005
100.00001
250.000025
500.00005
1000.0001

Compare one mm²/s with other units

Target unitEquivalent of 1 mm²/sDefinition guide
Square meters per second (m²/s)0.000001Read definition
Square centimeters per second (cm²/s)0.01Read definition
Square feet per hour (ft²/h)0.0387500775002Read definition

The laboratory scale for thermal diffusivity

One square millimeter per second is exactly 10^-6 m²/s, 0.01 cm²/s and about 0.03875 ft²/h. The unit suits measurements because most solids fall between about 0.1 and 150 mm²/s, which are numbers a reader can hold in mind. Polymers such as PMMA and polyethylene sit near 0.1 to 0.2 mm²/s, glass near 0.5, stainless steel near 4, aluminum near 97 and copper above 100. Water at room temperature is about 0.143 mm²/s. Thermal diffusivity, alpha = k / (rho c_p), measures how quickly a temperature change spreads through a material, so a high value means that a thin piece equalizes fast.

Reading a laser flash result

Laser flash instruments report diffusivity, often in mm²/s, from the rise in rear-face temperature of a small disc after a short pulse on the front face. In the ideal adiabatic case alpha = 0.1388 L² / t_half, where L is the thickness and t_half is the time to half of the maximum temperature rise. For a 2 mm aluminum disc and alpha of 97 mm²/s, t_half is 0.1388 x 4 / 97, or 5.72 ms. A 2 mm polymer disc with alpha of 0.1 mm²/s has t_half of 5.55 seconds. Thickness is therefore chosen to keep the half time long enough for the detector and short enough that heat loss does not dominate.

Centistokes look the same and mean something else

One square millimeter per second is also one centistoke, the common unit of kinematic viscosity for oils and fuels. A lubricant labelled 32 cSt at 40 C has a kinematic viscosity of 32 mm²/s, and that has no connection with how quickly heat spreads in it. The thermal diffusivity of a mineral oil is typically near 0.08 mm²/s, hundreds of times lower than its kinematic viscosity. Their ratio is the Prandtl number, which for such an oil is several hundred. A document that reports mm²/s without a property name can therefore be read two ways, and the converters cannot distinguish them. Take the property from the column heading or the test method.

Conversions in both directions

The factors are simple for metric neighbors. One mm²/s is 10^-6 m²/s and 0.01 cm²/s, so multiply by 0.000001 or 0.01. Going up, 1 m²/s is 1,000,000 mm²/s and 1 cm²/s is 100 mm²/s. The imperial step uses 1 ft²/h = 25.8064 mm²/s, so one mm²/s is 0.0387500775 ft²/h. Water at 0.143 mm²/s is 1.43 x 10^-7 m²/s, 0.00143 cm²/s and about 0.005541 ft²/h. Aluminum at 97 mm²/s is 9.7 x 10^-5 m²/s and about 3.759 ft²/h. The site lists mm²/s against m²/s, cm²/s and ft²/h as separate thermal diffusivity converters.

Choosing mm²/s for polymers, foods and ceramics

Insulating and organic materials have small diffusivities, so mm²/s keeps the numbers readable. Wood across the grain is typically a fraction of 1 mm²/s, foams lower still, and many food products have values near 0.1 to 0.15 mm²/s, because they are mostly water. Ceramics span a wide range from about 1 mm²/s for some oxides at room temperature to much higher for dense carbides and nitrides. Technical ceramics and polymers data sheets often include a table of diffusivity against temperature. Because the unit has the same dimension as the one used for viscosity, a data sheet from one supplier can list both in the same units, which makes it easy to read them in the wrong column.

Estimating heating times

The time for a temperature change to reach the middle of a plate of thickness L is of the order of L² / alpha. A 3 mm sheet of stainless steel with alpha 4 mm²/s needs about 9 / 4, or 2.25 seconds. A 3 mm polymer plate with alpha of 0.1 mm²/s takes 90 seconds, forty times longer from the same thickness. Doubling the thickness quadruples either figure. Since the formula scales with the square of the thickness, a thick polymer part heats and cools very slowly, which is why molded plastic parts need long cooling times in the mold. The estimate ignores contact resistance and surface heat transfer, so treat it as a lower bound for real processes.

Diffusivity falling with temperature in ceramics

Diffusivity is not a constant. For pure metals it changes slowly with temperature, while for crystalline ceramics and many other dielectric solids it falls markedly as the temperature rises above room temperature, because heat is carried by lattice vibrations whose mean free path shortens. Polymers change at their glass transition and melting points. Water changes slightly between 0 and 100 C. A tabulated 97 mm²/s for aluminum applies near 300 K, and the value at 500 K is lower. When a table gives alpha at several temperatures, convert each entry separately and keep its temperature label. The conversion factors do not depend on temperature.

Notation and reporting practice

The symbol is mm²/s, written with the superscript on the millimeter only, since the whole length is squared. Writing mm/s² would describe an acceleration, and mm/s describes a speed. Alpha is the usual quantity symbol. Many papers report diffusivity in mm²/s to two or three significant figures, with the temperature and the method such as laser flash. Keep these with the value when converting. The mm²/s numbers often come from rounding of an m²/s value such as 9.7 x 10^-5, so converting back may not reproduce the original digits. This is a rounding effect and says nothing against the conversion factor, which is exact.

Checking a value against its three ingredients

Diffusivity in mm²/s can be cross-checked from conductivity, density and specific heat. Multiply the SI result in m²/s by 1,000,000. For stainless steel with k = 16 W/(m K), density 8,000 kg/m³ and specific heat 500 J/(kg K), alpha is 16 / 4,000,000 = 4 x 10^-6 m²/s, which is 4 mm²/s. For a polymer with k = 0.2, density 1,200 and specific heat 1,500 the result is 0.2 / 1,800,000 = 1.11 x 10^-7 m²/s, or 0.111 mm²/s. If a data sheet lists conductivity, density and diffusivity but no specific heat, the same relation gives c_p = k / (rho alpha), a quick way to test whether the numbers are consistent. The inputs here are illustrative handbook-scale values.

Precision and checking

  • Retain source diffusivity precision.
  • Keep the square exponent.

Reference numbers are displayed with up to twelve significant digits. That display does not add precision to a rounded measurement. Keep source and target quantities compatible, confirm symbol case and regional conventions, and round the final result to precision justified by the input. Factors involving π or repeating fractions use finite numerical precision.

Use a working converter

Source and verification scope

The reference values and examples use the versioned unit definitions shared with the linked converters. Source dates identify the stated access or verification scope. A reverse calculation checks arithmetic and direction, but it does not independently verify a definition. Computandum is independent of the cited organizations, and the citations do not imply endorsement of this guide or a real application.

Sources

Read the calculation and sourcing methodology →